Z10PE-D8 WS
T15493 7.00 版 2019 年 5 月發行 版權說明 © ASUSTeK Computer Inc. All rights reserved.
Offer to Provide Source Code of Certain Software This product contains copyrighted software that is licensed under the General Public License (“GPL”), under the Lesser General Public License Version (“LGPL”) and/or other Free Open Source Software Licenses. Such software in this product is distributed without any warranty to the extent permitted by the applicable law. Copies of these licenses are included in this product.
目錄內容 安全性須知..................................................................................................................................... viii 電氣方面的安全性........................................................................................................... viii 操作方面的安全性........................................................................................................... viii REACH 資訊.................................................................................................................
目錄內容 2.6 2.7 2.8 2.9 2.5.5 PCI Express x8 插槽(x8 link)...................................................................2-16 內部開關................................................................................................................................2-18 內建指示燈............................................................................................................................2-20 跳線選擇區.............................................................................................................
目錄內容 4.5.9 CSM 設定...............................................................................................................4-21 4.5.10 可信任運算(Trusted Computing)..........................................................4-22 4.5.11 USB 設定(USB Configuration)...............................................................4-23 4.5.12 ASMedia 儲存控制器(ASMedia Storage Controller)....................4-24 4.5.13 iSCSI 設定.................................................................................................
目錄內容 5.3.1 建立 RAID 設定...................................................................................................5-25 5.3.2 刪除 RAID 磁區...................................................................................................5-27 5.3.3 重新設定硬碟為非陣列硬碟...........................................................................5-28 5.3.4 退出 Intel Rapid Storage Technology enterprise 程式.........................5-29 5.3.5 重建 RAID 設定.....................................................................
安全性須知 電氣方面的安全性 • 為避免可能的電擊造成嚴重損害,在搬動電腦主機之前,請先將電腦電源線暫時 從電源插槽中拔掉。 • 當您要加入硬體裝置到系統中或者要移除系統中的硬體裝置時,請務必先連接該 裝置的訊號線,然後再連接電源線。可能的話,在安裝硬體裝置之前先拔掉電腦 的電源供應器電源線。 • 當您要從主機板連接或拔除任何的訊號線之前,請確定所有的電源線已事先拔 掉。 • 在使用擴充卡之前,我們建議您可以先尋求專業人士的協助。這些裝置有可能會 干擾接地的迴路。 • 請確定電源供應器的電壓設定已調整到本國/本區域所使用的電壓標準值。若您不 確定您所屬區域的供應電壓值為何,那麼請就近詢問當地的電力公司人員。 • 如果電源供應器已損壞,請不要嘗試自行修復。請將之交給專業技術服務人員或 經銷商來處理。 操作方面的安全性 • 在您安裝主機板以及加入硬體裝置之前,請務必詳加閱讀本手冊所提供的相關資 訊。 • 在使用產品之前,請確定所有的排線、電源線都已正確地連接好。若您發現有任 何重大的瑕疵,請儘速聯絡您的經銷商。 • 為避免發生電氣短路情形,請務必將所有沒用到的螺絲、迴紋針及其他零件收 好,不要遺留在主機板上或電
REACH 資訊 注意:謹遵守 REACH(Registration, Evaluation, Authorisation, and Restriction of Chemicals) 管理規範,我們會將產品中的化學物質公告在華碩 REACH 網站,詳細請 參考 http://csr.asus.com/english/REACH.htm。 請勿將本主機板當作一般垃圾丟棄。本產品零組件設計為可回收利用。 這個打叉的垃圾桶標誌表示本產品(電器與電子裝置)不應視為一般垃 圾丟棄,請依照您所在地區有關廢棄電子產品的處理方式處理。 請勿將內含汞的電池當作一般垃圾丟棄。這個打叉的垃圾桶標誌表示電 池不應視為一般垃圾丟棄。 產品回收與處理 華碩與資源回收業者以最高標準相互配合,以保護我們的環境,確保工作者的安 全,以及遵從全球有關環境保護的法律規定。我們保證以資源回收的方式回收以往生 產的舊裝置,透過多樣的方式保護環境。 如欲了解更多關於華碩產品資源回收資訊與聯絡方式,請連線上網至 C S R (Corporate Social Responsibility)網頁:http://csr.asus.
限用物質名稱及含量列表 限用物質及其化學符號 單元 鉛 (Pb) 汞 (Hg) 鎘 (Cd) 六價鉻 多溴聯苯 多溴二苯醚 (Cr+6) (PBB) (PBDE) 印刷電路板 ─ ○ ○ ○ ○ ○ 電子組件 ─ ○ ○ ○ ○ ○ 連接器 ─ ○ ○ ○ ○ ○ 其他及其配件 ─ ○ ○ ○ ○ ○ 備考 1. "○" 係指該項限用物質之百分比含量未超出百分比含量基準值。 備考 2.
關於這本使用手冊 產品使用手冊包含了所有當您在安裝本主機板時所需用到的資訊。 使用手冊的編排方式 使用手冊是由下面幾個章節所組成: • 第一章:產品介紹 您可以在本章節中發現諸多華碩所賦予本主機板的優異特色。利用簡潔易懂的 說明讓您能很快地掌握本主機板的各項特性,當然,在本章節中我們也會提及所 有能夠應用在本主機板的新產品技術。 • 第二章:硬體裝置資訊 本章節描述所有您在安裝系統元件時必須完成的硬體安裝程序。詳細內容有: 處理器與記憶體安裝、跳線選擇區設定以及主機板的各種裝置接頭。 • 第三章:開啟電源 本章節說明開啟電腦電源的順序以及電腦開機後所發出各種不同類型嗶嗶聲的 代表意義。 • 第四章:BIOS 程式設定 本章節描述如何使用 BIOS 設定程式中的每一個選單項目來更改系統的組態設 定。此外也會詳加介紹 BIOS 各項設定值的使用時機與參數設定。 • 第五章:RAID 磁碟陣列設定 本章節提供本主機板的 RAID 設定資訊。 • 第六章:安裝驅動程式 本章節介紹本主機板驅動程式的安裝。 • 附錄 在本附錄裡包含您在設定本主機板時有可能會用到的資訊,並將列出相關的聯 絡資訊與認證資訊。 提示符號
跳線帽及圖示說明 主機板上有一些小小的塑膠套,裡面有金屬導線,可以套住選擇區的任二隻針腳 (Pin)使其相連而成一通路(短路),本手冊稱之為跳線帽。 有關主機板的跳線帽使用設定,茲利用以下圖示說明。以下圖為例,欲設定為 「Jumper™ Mode」,需在選擇區的第一及第二隻針腳部份蓋上跳線帽,本手冊圖示 即以塗上底色代表蓋上跳線帽的位置,而空白的部份則代表空接針。以文字表示為: [1-2]。 因此,欲設定為「JumperFree™ Mode」,以右圖表 示即為在「第二及第三隻針腳部份蓋上跳線帽」,以 文字表示即為:[2-3]。 1 2 Jumper Mode 2 3 Jumper Free (Default) 哪裡可以找到更多的產品資訊 您可以經由下面所提供的兩個管道來獲得您所使用的華碩產品資訊以及軟硬體的升 級資訊等。 1. 華碩網站 您可以到 http://tw.asus.com 華碩電腦全球資訊網取得所有關於華碩軟硬體產品的各 項資訊。台灣地區以外的華碩網址請參考手冊最後附錄裡的聯絡資訊。 2.
Z10PE-D8 WS 主機板規格列表 中央處理器 雙 Intel® Socket 2011-3 插槽,支援 Xeon® E5-2600 v3 / v4 系列 家族處理器 QPI 6.4 / 8.0 / 9.6 GT/s * 請上華碩官網 tw.asus.com 以取得 CPU 支援列表。 晶片組 記憶體模組 擴充插槽 Intel® C612 PCH 8 x DIMM(每個 CPU 支援 4 通道,每個 CPU 支援 4 根記憶體 模組),最高可擴充達 512GB 4GB, 8 GB, 16 GB, 32 GB (RDIMM) 32 GB, 64 GB (LRDIMM) DDR4 2400* / 2133* / 1866 / 1600 MHz RDIMM/LR-DIMM 四通道記憶體架構 * 實際記憶體頻率會依 Intel CPU 類型與記憶體模組而不同。安裝 E52600 v4 處理器時支援 2400MT/s。 ** 請上華碩官網 t w.a s u s.
Z10PE-D8 WS 主機板規格列表 音效功能 Realtek® ALC1150 8 聲道高傳真音效編解碼器 - 支援高傳真 112dB SNR 立體聲輸出(音源輸出孔位於後側 面板)和 104dB SNR 錄音輸入(音源輸入孔) - 支援 192khz/24bit 真正藍光無失真音效 - 藍光光碟音效內容保護 - DTS UltraPC II - DTS Connect - 支援音效介面偵測、多音源獨立輸出(Multi-Streaming)技 術與前端面板音效插孔功能 - 後側面板具備光纖 S/PDIF 數位輸出連接埠 USB 連接埠 ASMedia USB 3.0 控制器 - 4 x USB 3.0/2.0 連接埠,在主機板中央,供前側面板使用 - 2 x USB 3.0/2.0 連接埠,在主機板後側面板 Intel® C612 晶片組 - 4 x USB 3.0/2.0 連接埠(4 埠後側面板) - 4 x USB 2.0/1.
Z10PE-D8 WS 主機板規格列表 內部輸出/輸入插座 2 1 1 2 8 2 7 1 1 1 1 1 1 1 1 1 1 1 2 1 1 1 x x x x x x x x x x x x x x x x x x x x x x USB 3.0/2.0 插座,支援擴充 4 組 USB 埠(19-pin) USB 2.0/1/1 插座,支援擴充 2 組 USB 埠 M.2 Socket 3 插座 SATA Express 插座(黑色) SATA 6.
xvi
第一章: 產品介紹 您可以在本章節中發現諸多華碩所賦予本 主機板的優異特色,以及所有能夠套用在本 主機板的新產品技術。 1
1.1 歡迎加入華碩愛好者的行列! 再次感謝您購買此款華碩 Z10PE-D8 WS 主機板! 本主機板的問世除了再次展現華碩對於主機板一貫具備的高品質、高效能以及高穩 定性的嚴格要求,同時也新增了許多新的功能以及大量應用在它身上的最新技術,使 得 Z10PE-D8 WS 主機板成為華碩優質主機板產品線中不可多得的閃亮之星。 在您拿到本主機板包裝盒之後,請馬上檢查下面所列出的各項標準配件是否齊全。 1.2 產品包裝 請檢查下面所列出的各項標準配件是否齊全。 搭配擋板的 VGA 訊號線 訊號線 SATA 6G 傳輸線 12 -- 1 1 1 --1 2-Way SLI 橋接器 1 -- 3-Way SLI 橋接器 1 -- 4-Wat SLI 橋接器 1 -- 1 1 每盒 1 件 每盒 1 件 每盒 1 件 每箱 5 盒 COM 埠排線 輸出/輸入模組 2 埠 USB 2.
1.3 序號標籤 在尋求華碩技術支援團隊的技術支援之前,請務必留意一下主機板的序號,此序號 由 12 位字母組成(xxS2xxxxxxxx),如下圖所示。只有當您知道產品的正確序號, 華碩技術支援團隊成員才能針對您提出的問題提供更快速而讓您滿意的解決方案。 Z10PE-D8 WS xxS2xxxxxxxx Made in Taiwan 合格 1.4 特殊功能 1.4.1 產品特性 最新中央處理器 本主機板支援 Intel Xeon® E5-2600 V3 系列家族處理器,高階 IPC 設計可以提升系 統效能和浮點運算能力,並簡化了多核心編程,另外,E5-2600 V3 系列家族處理器 支援新世代處理器電源管理功能。Intel Xeon® E5-2600 V3 系列處理器提高了 I/O 埠 效能,並支援 QPI 連線速度達 9.6GT/s。 Intel® AVX 2.
支援 M.2 插槽 本主機板提供 M.2 插槽,可以共享 SATA 6Gb/s 埠與 PCI-E Gen3 x4 的頻寬,並專 供作業系統使用。 Intel® C612 系列晶片組 Intel® C612 系列晶片組支援企業級功能,適用於雲端及儲存類公用程式。C612 系 列晶片組結合最新的 Xeon® E5-2600 v3 處理器家族,與上一代產品相比,能夠更加 優化系統效能。同時能夠降低 TDP 值,並且支援 USB 3.
1.4.
1-6 第一章:產品介紹
第二章: 硬體裝置資訊 本章節描述了所有您在安裝系統元件 時所必須完成的硬體安裝程式。詳細內容 有:處理器與記憶體、跳線選擇區設定以 及主機板的各種裝置連接埠。 2
2.
2.2 主機板概觀 在您開始安裝之前,請確定您所購買的電腦主機機殼是否可以容納本主機板,並且 機殼內的主機板固定孔位是否能與本主機板的螺絲孔位吻合。 為了最佳化主機板功能,建議您將主機板安裝在一個相容 SSI EEB 的機殼內。 為方便在電腦主機機殼安裝或取出主機板,請務必先將電源供應器移 開!當您安裝或移除主機板的時候,必須確保電源供應器的插頭已經被 移除,否則可能導致主機板上的元件損壞。 2.2.1 主機板的擺放方向 當您安裝主機板到電腦主機機殼內時,務必確認置入的方向是否正確。帶有外部埠 的方向應是朝向主機機殼的後方面板,而且您也會發現主機機殼後方面板會有相對應 的預留孔位。請參考下圖所示。 2.2.
2.2.
2.2.4 主機板元件說明 插槽 頁碼 1. 中央處理器插槽 2-7 2. DDR4 記憶體插槽 2-12 3. PCI Express x16 插槽 2-16 內部按鈕與開關 頁碼 1. 開機按鈕 2-18 2. 重置按鈕 2-18 3. Dr. Power 開關(DR_POWER) 2-19 內部指示燈 頁碼 1. 記憶體錯誤指示燈(ERR_DIMMA1, ERR_DIMMB1, ERR_DIMMC1, ERR_DIMMD1, ERR_DIMME1, ERR_DIMMF1, ERR_DIMMG1, ERR_ DIMMH1) 2-20 2. 遠端管理控制器指示燈(BMC_LED1) 2-20 3. Location 指示燈(LOCLED2) 2-21 4. CATT 指示燈(CATTERR_LED1) 2-21 5. CPU 警告指示燈(ERR_CPU1, ERR_CPU2) 2-22 6. M2 指示燈(M2_LED) 2-22 7. 華碩 Dr. Power 指示燈(PGLED3) 2-23 8.
後側面板連接插槽 頁碼 1. PS/2 滑鼠與鍵盤複合埠 2-33 2. Q-Code 載入按鈕 2-33 3. 光纖 S/PDIF 輸出埠 2-33 4. USB 3.0 連接埠 5 和 6 2-33 5. 網路埠 2 2-33 6. 網路埠 1(RJ-45 連接埠為提供網路埠 1 與 BMC 共享) 2-33 7. 8 聲道音效輸入/輸出埠 2-33 8. USB 2.0 連接埠 7 和 8 2-33 9. USB BIOS Flashback 按鈕 2-33 10. USB 3.0 連接埠 3 和 4 2-33 11. USB 3.0 連接埠 1 和 2 2-33 內部連接插槽 頁碼 1. 硬碟動作指示燈連接排針(4-pin HDLED1) 2-36 2. USB 2.0 連接埠(10-1 pin USB910) 2-36 3. USB 3.0 連接埠(20-1 pin USB3_34;USB3_E12) 2-37 4.
2.3 中央處理器(CPU) 本主機板具備兩個 LGA 2011-3 處理器插槽,本插槽是專為 LGA 封裝的 Intel® Xeon E5-2600 V3 系列家族處理器所設計。 • 在您購買本主機板之後,請確認在處理器插座上附有一個 PnP 保護 蓋,並且插座接點沒有彎曲變形。若是保護蓋已經毀壞或是沒有保護 蓋,或者是插座接點已經彎曲,請立即與您的經銷商聯絡。 • 在安裝完主機板之後,請將 PnP 保護蓋保留下來。只有 LGA2011-3 插槽上附有 PnP 保護蓋的主機板符合 Return Merchandise Authorization (RMA)的要求,華碩電腦才能為您處理產品的維修與保固。 • 本保固不包括處理器插座因遺失、錯誤的安裝或不正確的移除 P n P 保護蓋所造成的毀壞。 2.3.1 安裝中央處理器 請依照以下步驟安裝處理器: 1.
2. 用姆指按下下左側固定扳手 (A) 並將其稍向右側推(B),直到扳手脫離固定 扣並輕輕抬起固定扳手(C)。 CPU 安裝盒上的 PnP 保護蓋是用以保護插槽上的接腳之用,因此只有在 CPU 安裝妥當之後,才可將其移除。 固定 扳手 3.
4. 將左側固定扳手往箭頭方向推以抬起安 裝盒上蓋(G)。 安裝盒上蓋邊緣 請勿將固定扳手插入固定扣。 5. 拿住邊緣,然後輕輕拿起安裝盒上蓋 (H)。 安裝盒 上蓋 6. 拿起 CPU。 7. 將 CPU 對準插槽,確保 CPU 上的金三 角標誌對準插槽上的上三角標誌。 8. 小心地將 CPU 放入插槽。 三角標誌 CPU 只能以單一方向正確地安 裝到主機板上的插槽。切記請 勿用力地將 C PU 以錯誤的方 向安裝到插槽上,這麼做將可 能導致 CPU 與插槽上的接腳 損壞。 9.
10. 推下右側固定扳手(I),確保安裝盒上蓋的邊緣被扳手固定(J)。然後將右側固定 扳手嵌入固定扣下。 當右側固定扳手嵌入固定扣後從安裝盒上蓋取出 PnP 保護蓋。 請將 PnP 保護蓋保留下來。只有 LGA2011-3 插槽上附有 PnP 保護蓋的 主機板符合 Return Merchandise Authorization(RMA)的要求,華碩電腦 才能為您處理產品的維修與保固。 PnP 保護蓋 11.
12. 在 CPU 裸露在外面的區域上滴入几滴 散熱膏,與散熱片接觸。散熱器散熱膏 必須只有很薄的一層。 • 請確認散熱膏塗抹為均勻 薄層。 • 有些散熱片已有散熱膏。 如果是,則跳過這一步。 注意:請勿食用散熱膏。如進入眼睛或皮膚,請立即清洗,並尋求專業 醫師的協助。 13.
2.4 系統記憶體 2.4.1 概觀 本主機板每 CPU 配置有八(8)組 DDR4 DIMM(Double Data Rate,雙倍資料傳輸 率)記憶體插槽。 下圖所示為 DDR4 記憶體插槽在主機板上的位置。 2.4.
單顆 CPU 設定 單顆 CPU 設定下您可以參考以下記憶體建議設定。 單 CPU 設定(必須安裝在 CPU1 插槽上面) 記憶體模組插槽 A1 B1 1 DIMM P 2 DIMMs P P 4 DIMMs P P C1 D1 P P 兩顆 CPU 設定 兩顆 CPU 設定下您可以參考以下記憶體建議設定。 雙 CPU 設定 記憶體模組插槽 A1 B1 2 DIMMs P 4 DIMMs P P 8 DIMMs P P C1 D1 E1 F1 G1 H1 P P P P P P P P P 華碩 Z10PE-D8 WS 主機板使用手冊 2-13
2.4.3 安裝記憶體模組 請依照下面步驟安裝記憶體模組: 1. 先將記憶體模組插槽一端的白色固定卡 扣扳開。 2. 將記憶體模組的金手指對齊記憶體模組 插槽的溝槽,並且在方向上要注意金手 指的缺口要對準插槽的凸起點。 記憶體模組缺口 記憶體模組插槽凸起點 扳開固定卡扣 由於記憶體模組金手指部分均有缺口設計,因此只能以一個固定方向安 裝到記憶體模組插槽中。請勿強制插入以免損及記憶體模組。 3. 最後緩緩將記憶體模組插入插槽中,若 無錯誤,插槽一端的白色卡扣會因記憶 體模組置入而自動扣到記憶體模組一端 的凹孔中。 卡扣會在記憶體模組正 確安裝後自動扣上 請以垂直方向插入記憶體模組,防止記憶體模組缺口損壞。 2.4.4 取出記憶體模組 請依照以下步驟取出記憶體模組: 1. 壓下記憶體模組插槽一端白色的固定 卡扣以鬆開記憶體模組。 2.
2.5 擴充插槽 為了因應未來會擴充系統效能的可能性,本主機板提供了擴充插槽,在接下來的小 節中,將會描述主機板上這些擴充插槽的相關訊息。 安裝/移除任何擴充卡之前,請暫時先將電腦的電源線拔出。如此可免除 因電氣殘留於電腦中而發生的意外狀況。 2.5.1 安裝擴充卡 請依照下列步驟安裝擴充卡: 1. 在安裝擴充卡之前,請先詳讀該擴充卡的使用說明,並且要針對該卡作必要的硬 體設定變更。 2. 鬆開電腦主機的機殼蓋並將之取出(如果您的主機板已放置在主機內)。 3. 找到一個您想要插入新擴充卡的空置插槽,並以十字螺絲起子鬆開該插槽位於主 機背板的金屬擋板的螺絲,最後將金屬擋板移出。 4. 將擴充卡上的金手指對齊主機板上的擴充槽,然後慢慢地插入槽中,並以目視的 方法確認擴充卡上的金手指已完全沒入擴充槽中。 5. 再用剛才鬆開的螺絲將擴充卡金屬擋板鎖在電腦主機背板以固定整張卡。 6. 將電腦主機的機殼蓋裝回鎖好。 2.5.2 設定擴充卡 在安裝好擴充卡之後,接著還須通過軟體設定來調整該擴充卡的相關設定。 1.
2.5.3 指派中斷要求 標準中斷要求使用一覽表 IRQ 順序 指派功能 0 1 系統計時器 1 2 鍵盤控制器 2 - 可設定之岔斷控制卡 3* 11 通訊埠 (COM2) 4* 12 通訊埠 (COM1) 5 13 -- 6 14 軟碟機控制器 7* 15 -- 8 3 系統 CMOS/即時時鐘 9* 4 ACPI 模式 * 10 5 預留給 PCI 裝置使用 11* 6 預留給 PCI 裝置使用 12* 7 PS/2 相容滑鼠埠 13 8 數值資料處理器 14 9 第一組 IDE 通道 15* 10 第二組 IDE 通道 * * *:這些通常是留給 ISA 或 PCI 擴充卡使用。 2.5.
主機板構造圖 PCIE 1 PCIE 2 PCIE 3 PCIE 4 PCIE 5 PCIE 6 PCIE 7 1 x PCIE x16(x16 Gen3 Link) (靠近 CPU socket 插座。當插槽 2 已使用時,會自動切換為 x8 Link) 1 x PCIE X16(x8 Gen3 Link) 1 x PCIE x16(x16 Gen3 Link) (當插槽 4 已使用時,會自動切換為 x8 Link) 1 x PCIE X16(x8 Gen3 Link) 1 x PCIE x16(x16 Gen3 Link) 1 x PCIE x16(x8 Gen3 Link) 1 x PCIE x16(x16 Gen3 Link) 華碩 Z10PE-D8 WS 主機板使用手冊 2-17
2.6 內部開關 當您想要針對未安裝在機殼的裸板或是開放機殼的系統作效能調校時,主機板上內 建的開關按鈕與重置按鈕可以方便您迅速地開關機或是重置系統。 1. 開機開關 本主機板擁有開機開關,讓您可以喚醒系統或開機,並以燈號顯示系統為開啟、睡 眠模式或在軟關機的狀態,這個燈號用來提醒您在本主機板移除或插入任何元件之前 要先關機。下圖顯示開關在主機板上的位置。 2.
3. Dr. POWER 開關 這個開關提供您啟用或關閉華碩 Dr. Power 功能。當啟用本功能時,請安裝產 品所附的華碩 Dr.
2.7 內建指示燈 1. 記憶體錯誤指示燈(E R R_D I M M A1、E R R_D I M M B1、E R R_D I M M C1、E R R_ DIMMD1、ERR_DIMME1、ERR_DIMMF1、ERR_DIMMG1、ERR_DIMMH1) 當燈亮起表示對應的記憶體模組出現錯誤。 2.
3. Location 指示燈(LOCLED2) 當按下主機板上的位置按鈕,或受到系統管理軟體驅動後此指示燈會亮起。本 指示燈可以協助您找到發生錯誤的伺服器所在位置。 4.
5. CPU 警告指示燈(ERR_CPU1、ERR_CPU2) 當 CPU 警告指示燈亮起時,則表示對應的 CPU 出現錯誤。 6. M2 指示燈(M2_LED) 當 M2 指示燈亮燈時,則表示所安裝的 M.
7. 華碩 Dr. Power 指示燈 華碩 Dr. Power 指示燈設計在靠近華碩 Dr. Power 開關旁,當按下華碩 Dr.
8.
Q-Code 列表(續上頁表格) Code 31 32 – 36 37 – 3A 3B – 3E 4F 50 – 53 54 55 56 57 58 59 5A 5B 5C – 5F E0 E1 E2 E3 E4 – E7 E8 E9 EA EB EC – EF F0 F1 F2 F3 F4 F5 – F7 F8 F9 FA FB – FF 60 61 62 說明 記憶體已安裝 CPU Post-Memory 初始化 Post-Memory System Agent 初始化已開始 Post-Memory PCH 初始化已開始 DXE IPL 已開始 記憶體初始化錯誤。無效的記憶體類型或不相容記憶體速度 未知的記憶體初始化錯誤 記憶體未安裝 無效的 CPU 類型或速度 CPU 不匹配 CPU 自我檢測失敗或可能的 CPU 快取錯誤 未發現 CPU micro-code 或 micro-code 更新失敗 內部 CPU 錯誤 重置 PPI 不可用 預留給將來 AMI 錯誤代碼 S3 喚醒已開始 (S3 Resume PPI is called by the DXE IPL) S3 開機腳本執行 視訊重新發佈 O
Q-Code 列表(續上頁表格) Code 63 – 67 68 69 6A 6B – 6F 70 71 72 73 – 77 78 79 7A – 7F 90 91 92 93 94 95 96 97 98 99 9A 9B 說明 CPU DXE 初始化已開始 PCI 主橋接器初始化 System Agent DXE 初始化已開始 System Agent DXE SMM 初始化已開始 System Agent DXE 初始化 (限定 System Agent 模組) 9C 9D 9E – 9F A0 A1 A2 A3 A4 A5 A6 A7 A8 A9 AA AB USB 偵測 USB 開啟 預留給將來 AMI 代碼 IDE 初始化已開始 IDE 重置 IDE 檢測 IDE 開啟 SCSI 初始化已開始 SCSI 重置 SCSI 偵測 SCSI 開啟 設定驗證密碼 設定開始 預留給 ASL (參考以下 ASL 狀態代碼的說明) 設定輸入等待 PCH DXE 初始化已開始 PCH DXE SMM 初始化已開始 PCH 裝置初始化 PCH DXE 初始化 (限定 PCH 模組) ACPI 模組初始化
Q-Code 列表(續上頁表格) Code AC AD AE AF B0 B1 B2 B3 B4 B5 B6 B7 B8– BF D0 D1 D2 D3 D4 D5 D6 D7 D8 D9 DA DB DC 說明 預留給 ASL (參考以下 ASL 狀態代碼的說明) 可開機項目 延遲開機項目 退出 Boot Services 項目 Runtime Set Virtual Address MAP 開始 Runtime Set Virtual Address MAP 結束 Legacy Option ROM 初始化 系統重置 USB 熱抽換 PCI 熱抽換匯流排 清除 NVRAM 配置重置 (NVRAM 重置) 預留給將來 AMI 代碼 CPU 初始化錯誤 System Agent 初始化錯誤 PCH 初始化錯誤 某些架構協定不可用 PCI 資源分配錯誤。沒有資源 儲存 Legacy Option ROM 空間不足 未發現 Console 輸出裝置 未發現 Console 輸入裝置 無效的密碼 載入開機項目時發生錯誤 (LoadImage 返回錯誤) 開機項目失敗 (StartImage 返回錯誤) Flash
2.8 跳線選擇區 1. 清除 RTC RAM 資料(CLRTC1) 主機板上的 CMOS 唯讀記憶體(RTC RAM)中記載著正確的時間與系統硬體配 置等資料,這些資料並不會因電腦電源的關閉而遺失資料與時間的正確性,因為這 個 CMOS 的電源是由主機板上的鋰電池所供應。 想要清除這些資料,可以依照下列步驟進行: 1. 關閉系統電源,拔掉電源線; 2. 將 CLRTC1 跳線帽由 [1-2](預設值)改為 [2-3] 約 5~10 秒鐘 (此時即清 除 CMOS 資料),然後再將跳線帽改回 [1-2]; 3. 插上電源線,開啟電源; 4.
2. 顯示晶片控制器設定(3-pin VGA_SW1) 此跳線可讓您開啟或關閉內建的顯示晶片控制器。將跳線設定為 [1-2] 短路為 開啟顯示晶片功能。 3.
4. RAID 程式設定選擇(3-pin RAID_SEL1) 此跳線用來選擇建立 RAID 磁碟陣列的 RAID 設定程式。若您要使用第三方 LSI MegaRAID 軟體 RAID 公用程式 (預設),請設為 [1–2] 短路;若要使用 Intel® Rapid Storage Technology Enterprise SATA Option ROM 公用程式,請設為 [2–3] 短路。 5.
6. DDR4 散熱事件設定(3-pin DIMMTRIP1) 此跳線用來開啟/關閉 DDR4 DIMM 熱能偵測事件的接針。 7. PMBus 1.
8.
2.9 元件與周邊裝置的連接 2.9.1 後側面板埠 1. PS/2 鍵盤/滑鼠埠(紫色/綠色):將 PS/2 鍵盤或滑鼠插頭連接到此埠。 2. Q-Code Logger 按鈕:這個按鈕提供您檢視 Q-Code 事件記錄。如欲瞭解更多詳細 說明,請參考本手冊裡 使用 Q-Code logger 一節的說明。 3. 光纖 S/PDIF 輸出埠:這個連接埠為提供連接支援 S/PDIF(Sony/Philips Digital Interconnect Format )標準的裝置或喇叭。 4. USB 3.0 連接埠 5 和 6:這兩組 9-pin 通用序列匯流排(USB)埠可連接至使用 USB 3.0 規格的硬體裝置。 5. RJ-45 網路埠 2:此埠可經網路集線器連接至區域網路(Local Area Network, LAN),達到 Gigabit 連線。請參考下頁表格中各燈號的說明。 6. RJ-45 網路埠 1(網路埠 1 與 BMC 共享):此埠可經網路集線器連接至區域網 路(Local Area Network,LAN),並提供 BMC 管理功能。 7.
網路埠指示燈說明 ACT/LINK 指 速度指 示燈 示燈 Activity/Link 指示燈 速度指示燈 狀態 描述 狀態 熄滅 沒有連接 熄滅 連接速度 10Mbps 橘色 連接 橘色 連接速度 100Mbps 閃爍 資料傳輸中 綠色 連接速度 1Gbps 描述 網路埠 管理網路埠指示燈說明 ACT/LINK 指 速度指 示燈 示燈 Activity/Link 指示燈 速度指示燈 狀態 描述 狀態 熄滅 沒有連接 熄滅 連接速度 10Mbps 橘色 連接 橘色 連接速度 100Mbps 閃爍 資料傳輸中 綠色 連接速度 1Gbps 描述 網路埠 2、4、6 或 8 聲道音效設定 接頭 耳機/ 2 聲道 4 聲道 6 聲道 8 聲道 淺藍色 聲音輸入端 聲音輸入端 聲音輸入端 聲音輸入端 草綠色 聲音輸出端 前置喇叭輸出 前置喇叭輸出 前置喇叭輸出 粉紅色 麥克風輸入 麥克風輸入 麥克風輸入 麥克風輸入 中央聲道/重低音 喇叭輸出 橘色 – – 中央聲道/重低音 喇叭輸出 黑色
使用 Q-Code logger Q-Code Logger 可以提供您在無需打開電腦機殼便能輕鬆檢視 Q-Code 事件記錄。 請依照以下方式,使用 Q-Code logger: 1. 將 USB 儲存裝置插入專用的 Q-Code logger USB 連接埠。 2. 按下 Q-Code logger 按鈕超過 3 秒鐘,直到 Flashback 指示燈閃爍三次,表示 Q-Code logger 功能已啟動。 Q-Code logger Q-Code logger 按鈕 連接埠 使用 USB BIOS Flashback USB BIOS Flashback 提供您不需要進入 BIOS 程式或作業系統,便能以最簡單的方 式更新 BIOS 檔案。 請依照以下方式,使用 USB BIOS Flashback: 1. 從華碩網站下載最新的 BIOS 檔案。 2. 將取得的 BIOS 檔案更名為 Z10PEWS.CAP。 3. 將 Z10PEWS.CAP 檔案複製到 USB 行動儲存裝置的根目錄底下。 4.
2.9.2 內部連接埠 1. 硬碟動作指示燈號接針(4-pin HDLED1) 這個排針為提供您連接至安裝的 SATA 或 SAS 控制卡,並且當該卡有連接硬碟且 有存取動作時,主機板上的 LED 指示燈則會亮燈顯示。 2. USB 2.0 連接埠(10-1 pin USB910) 這些連接埠可以用來連接 U S B 2.0 擴充埠。將 U S B 模組傳輸線連接到 USB910,然後將模組套件安裝到機殼背部的一個空置的插槽位置。這組 USB 連 接埠支援 USB 2.
3. USB 3.0 連接插槽(20-1 pin USB3_34;USB3_E12) 這些插槽用來連接 USB 3.0 模組,可在前面板或後側連接埠擴充 USB 3.0 模 組。當您安裝 USB 3.0 模組,您可以享受 USB 3.0 的益處,包括有更快的資料傳 輸率最高達 5Gbps、對可充電的 USB 裝置更快的充電速度、最佳化能源效率,以 及與 USB 2.0 向下相容。 4.
5. 電源 SMBus 連接插座(PSUSMB1) 您可以透過本組插座連接到電源系統管理匯流排(SMBus,System Management Bus)介面裝置來讀取電源訊息。裝置透過 SMBus 介面與 SMBus 主機與/或其他 SMBus 裝置進行通訊。 6.
7. Serial ATA 6.
8. SATAEXPRESS 連接埠(7-pin SATAEXPRESS1 [上方的連接埠];SATAEXPRESS2 [下方的連接埠]) 這些插座為提供使用 Serial ATA 6 Gb/s 訊號線連接 Serial ATA 6 Gb/s 硬碟機。 • ASMedia 儲存控制器僅支援 AHCI 模式。 • 這些 SATA 連接埠為僅支援硬碟當作資料碟使用。 • SATAEXPRESS1-2 連接埠不支援一組 SATA Express 裝置或是兩組 SATA 裝置。 9.
10. M.2 (NGFF) 埠(NGFF1) 這個插槽用來安裝 M.2(NGFF)裝置。 這個插槽支援 PCI-E 和 SATA 埠的 2260/2280/22110 類型儲存裝置。 M.2(NGFF)固態硬碟模組為選購配備,請另行購買。 11.
12. EATX 電源插座(24-pin EATXPWR1;8-pin EATX12V1/EATX12V2;6-pin EATX12V3) 這個插座為提供給 E A T X 電源使用。由電源所提供的連接插頭已經過特別設 計,只能以一個特定方向插入主機板上的電源插座。找到正確的插入方向後,僅 需穩穩地將之套進插座中即可。 • 請不要忘記連接 24+8+8-pin 電源插座,否則系統將不會開機。 • 當安裝兩張顯示卡或視訊卡時,建議您連接 6-pin EATX 12V3 電源插 座。 • 如果您想要安裝其他的硬體裝置,請務必使用較高功率的電源供應器 以提供足夠的裝置用電需求。若電源供應器無法提供裝置足夠的用電 需求,則系統將會變得不穩定或無法開啟。 • 此主機板支援 EATX 2.
13.
14.
15.
16. 數位音效連接排針(4-1 pin SPDIF_OUT) 這組排針是用來連接 S/PDIF 數位音效模組,您可以利用這組排針以 S/PDIF 音 效訊號線連接到音效裝置的數位音訊輸出端,使用數位音訊輸出來代替傳統的類 比音訊輸出。 S/PDIF 模組為選購配備,請另行購買。 17.
18. VGA 連接排針(10-1 pin VGA_HDR1) 這個排針支援 VGA 高動態範圍(High Dynamic-Range)介面。 19.
2-48 第二章:硬體裝置資訊
第三章: 開啟電源 本章節說明開啟電腦電源的順序,以及 電腦開機後所發出各種不同類型嗶聲的代 表意義。 3
3.1 第一次啟動電腦 1. 確認所有排線與接腳都接妥,然後蓋上機殼的外蓋。 2. 確定所有的開關都已關閉 3. 將電源線接上機殼背面的電輸入插座。 4. 情況許可的話,最好將電源線路上加接突波吸收/保護器。 5. 您可以先開啟以下周邊裝置的電源: 6. a. 顯示器 b. 外接儲存裝置(從串連的最後一個裝置開始) c.
3.2 關閉電源 3.2.1 使用作業系統關閉功能 如果您使用的作業系統為 Windows® 2008 R2: 1. 點選“開始”,選擇“關機”。 2. 從“關閉事件追蹤程式”中選擇一個選項,此選項最能說明您希望關閉電腦的原 因。 3. 請確認您勾選了“計畫的”選擇框。 4. 如果需要,您可以輸入註釋。 5. 點選“確定”。 如果您使用的作業系統為 Windows® Server 2012: 1. 按下++。 2. 點選位於螢幕右下角的電源按鈕。 3. 選擇“關機”。 4. 從“關閉事件追蹤程式”中的選項欄選擇“其他”(計劃),否則請選擇一選項最 能說明您希望關閉電腦的原因。 5. 點選“繼續”。 3.2.
3-4 第三章:開啟電源
第四章: BIOS 程式設定 在電腦系統中,BIOS 程式調校的優劣與 否和整個系統的執行效能有極大的關係。針 對您自己的配備來作最最佳化 BIOS 設定是 讓您的系統效能再提昇的關鍵。接下來本章 節將逐一說明 BIOS 程式中的每一項設定。 4
4.1 管理、更新您的 BIOS 程式 下列軟體讓您可以管理與更新主機板上的 BIOS 設定。 1. ASUS CrashFree BIOS 3 當 BIOS 程式毀損時,使用可開機的 USB 隨身碟來更新 BIOS 程式。 2. ASUS EZ Flash 使用 USB 隨身碟更新 BIOS。 3. BUPDATER 使用可開機的 USB 隨身碟在 DOS 環境下更新 BIOS 程式。 上述軟體請參考相關章節的詳細使用說明。 建議您先將主機板原始的 BIOS 程式備份到可開機的 USB 隨身碟中, 以備您往後需要再度安裝原始的 BIOS 程式。使用華碩線上更新(ASUS Update)程式來拷貝主機板原始的 BIOS 程式。 4.1.
4.1.2 使用華碩 EZ Flash 更新程式 華碩 EZ Flash 程式讓您能輕鬆的更新 BIOS 程式,可以不必再透過開機片的冗長程 序或是到 DOS 模式下執行。 請至華碩網站 http://tw.asus.com 下載最新的 BIOS 程式檔案。 請依照下列步驟,使用 EZ Flash 來更新 BIOS: 1. 將已存好最新版 BIOS 檔案的 USB 隨身碟插入 USB 連接埠。 2. 進入 BIOS 設定程式。來到 Tools 選單,選擇 ASUS EZ Flash Utility 後並按下 鍵將其開啟。 ASUS Tek.
4.1.3 BUPDATER 工具程式 以下的 BIOS 畫面僅供參考,請依您所見的實際 BIOS 畫面為準。 BUPDATER 工具程式可以提供您在 DOS 環境下,使用儲存有更新的 BIOS 檔案的 USB 隨身碟來更新 BIOS 檔案。 更新 BIOS 檔案 請依照以下的步驟,使用BUPDATER 工具程式來更新 BIOS 檔案: 1. 請先造訪華碩網站(tw.asus.com)下載最新主機板的 BIOS 檔案。並將檔案儲存 至可開機的 USB 隨身碟內。 2. 然後將華碩支援網站(support.asus.com)上的 BUPDATER 工具程式(BUPDATER. exe),下載並儲存至同一個可開機的 USB 隨身碟內。 3. 將系統開機至 DOS 環境下,然後使用鍵盤輸入指令: BU PDA TER /i [fi l e na me ] . C AP [ filename] 這裡的意思就是輸入存放在 USB 隨身碟裡頭的最新或原本 BIOS 檔案名 稱,然後按 鍵。 A:\>BUPDATER /i[file name].
4. 程式會進行檢查檔案,然後開始更新 BIOS 檔案。 ASUS Tek. EzFlash Utility Current Platform Platform : Z10PE-D8 WS Version : 0215 Build date: 05/13/2014 Start Programming Flash. New Platform Platform : Z10PE-D8 WS Version : 0217 Build date: 06/30/2014 DO NOT SHUTDOWN THE SYSTEM!!! Write 75% 請勿在更新 BIOS 程式檔案時關閉或重新啟動系統,此舉將會導致系統損 毀! 5. 完成更新後,程式會回到 DOS 畫面,請重新啟動系統,透過硬碟開機。 The BIOS update is finished! Please restart your system. C:\> 華碩 Z10PE-D8 WS 主機板使用手冊 4-5
4.2 BIOS 程式設定 主機板擁有一片可編輯的韌體晶片,您可以依照 4.
4.2.1 BIOS 程式選單介紹 選單項目 功能表列 設定值 一般說明 操作功能鍵 4.2.
4.2.3 選單項目 於功能表列選定選項時,被選擇的功能將會反白,假設您選擇 Main 功能,則會顯 示 Main 選單的項目。 點選選單中的其他項目(如:Event Logs、Advanced、Monitor、Boot、Tool 與 Exit 等)也會出現該項目不同的選項。 4.2.4 子選單 在選單畫面中,若功能選項的前面有一個小三角形標記,代表此為子選單,您可以 利用方向鍵來選擇,並且按下 鍵來進入子選單。 4.2.5 操作功能鍵說明 在選單畫面的右下方為操作功能鍵說明,請參照功能鍵說明來選擇及改變各項功 能。 4.2.6 一般說明 在選單畫面的右上方為目前所選擇的作用選項的功能說明,此說明會依選項的不同 而自動變更。 4.2.
4.3 主選單(Main menu) 當您進入 BIOS 設定程式時,首先出現的第一個畫面即為主選單,內容如下圖。 4.3.1 System Date [Day xx/xx/xxxx] 設定您的系統日期。 4.3.
4.
4.5 進階選單(Advanced menu) 進階選單可讓您改變中央處理器與其他系統裝置的設定。 請注意當變更進階選單(Advanced menu)裡的項目時,在欄位中輸入不 正確的數值將會導致系統運作不正常。 Front Panel Type [HD Audio] 提供您設定前面板音效輸入類型。設定值有:[HD Audio] [AC97] SPDIF Out Type [SPDIF] 提供您選擇系統的 SPDIF 輸出類型。設定值有:[SPDIF] [HDMI] Dr. Power Policy [Standard] 提供您選擇 Dr.
4.5.1 ACPI 設定 Enable ACPI Auto Configuration [Disabled] 本項為啟用或關閉 BIOS ACPI 自動設定。設定值有:[Disabled] [Enabled] Enable Hibernation [Enabled] 本項啟用或關閉 Hibernation 功能(OS/ 休眠狀態)設定值有:[Disabled] [Enabled] 本項目可能對部分作業系統無任何作用。 4.5.
4.5.
4.5.
4.5.
Terminal Type [VT-UTF8] 提供您設定終端類型。 [VT100] ASCII 字元設定。 [VT100+] 延伸 VT100 支援顏色、功能鍵等等。 [VT-UTF8] 使用 UTF8 加密以映像 Unicode(萬國碼)字元在 1 或更多位 元組以上。 [ANSI] 延伸 ASCII 字元設定。 Bits per second [57600] 提供您選擇序列埠傳輸速度,這速度必須與另一邊符合,過長或過多都可能會 導致速度變慢。設定值有:[9600] [19200] [38400] [57600] [115200] Data Bits [8] 設定值有:[7] [8] Parity [None] 一個 p a r i t y(同位)位元能發送資料位元來檢測一些傳輸錯誤,[M a r k] 與 [Space] parity 則不允許錯誤檢測。 [None] None。 [Even] 同位位元為 0,表示 N 個位元裡,1 出現的總次數為偶數。 [Odd] 同位位元為 0,表示 N 個位元裡,1 出現的總次數為奇數。 [Mark] 同位位元總是 1
Redirection After BIOS POST [Bootloader] 當 Bootloader 已被選擇超過傳統控制台轉向,則允許您設定本項。設定值有: [Always Enable] [Bootloader] Serial Port for Out-of-Band Management/ Windows Emergency Management Services (EMS) Settings COM2 Console Redirection [Enabled] 啟用或關閉控制台轉向功能。設定值有: [Disabled] [Enabled] 當 Console Redirection 設定為 [Enabled] 時,以下的項目才會顯示。 Console Redirection Settings Out-of-Band Mgmt Port [COM1] 經由序列埠來遠端遙控管理 Windows Server 系統。設定值有:[COM1] [COM2] Terminal Type [VT-UTF8] 此為微軟 Windows Emergency Management Services (EM
4.5.
4.5.
4.5.
4.5.
4.5.
4.5.
USB hardware delays and time-outs USB transfer time-out [20 sec] 暫停數值,提供控制、bulk 與中斷傳輸。設定值有:[1 sec] [5 sec] [10 sec] [20 sec] Device reset time-out [20 sec] USB 大量儲存裝置起始單元指令暫停時間。設定值有:[10 sec] [20 sec] [30 sec] [40 sec] Device power-up delay [Auto] 在做適當的自我回報給 Host Controller(主機控制器)之前,提供您在設定採用最 大時間值。設定值有:[Auto] [Manual] Mass Storage Devices Generic 8.07 [Auto] 暫停數值,提供控制、bulk 與中斷傳輸。設定值有:[Enabled] [Disabled] [Auto] 4.5.
4.5.
4.
4.6.
Enable SMX [Disabled] 啟用 Safer Mode Extensions(SMX)功能。設定值有:[Disabled] [Enabled] Hardware Prefetcher [Enabled] 本項目提供您開啟或關閉中間層快取(mid level cache,L2)streamer prefetcher 功 能。設定值有:[Disabled] [Enabled] Adjacent Cache Line Prefetch [Enabled] 本項目提供您啟用或關閉調整快取線預取(Adjacent Cache Line Prefetch)功能。 設定值有:[Disabled] [Enabled] DCU Streamer Prefetcher [Enabled] 本項目為啟用或關閉 L1 資料 prefetcher。設定值有:[Disabled] [Enabled] DCU IP Prefetcher [Enabled] 本項目提供您啟用或關閉下一個基於隨著在載入記錄之上的 L1 線。設定值有: [Disabled] [Enabled] DCU Mode [32K 8Way W
4.6.
Power/Performance Switch [Enabled] 提供您在 P o w e r(電源)或 p e r f o r m a n c e(效能)之間切換。設定值有: [Disabled] [Enabled] Workload Configuration [Balanced] 最佳化工作負載特性。設定值有:[Balanced] [I/O sensitive] Averaging Time Window [23] 這個項目為使用在控制平均 CO 與 PO 時間的有效視窗。 PO TotalTimeThreshold Low [35] 當總 PO 時間少於這個設定值時,HW 開關機制會關閉效能設定為 (0) 。 PO TotalTimeThreshold High [58] 當總 PO 時間大於這個設定值時,HW 開關機制會關閉效能設定為 (0) 。 4.6.
4.6.4 QPI 設定 QPI General Configuration QPI Status 本項目為顯示有關 QPI 狀態的相關資訊。 Link Speed Mode [Fast] 本項目為設定 QPI 連線速度為任一快速模式(fast mode)或是慢速模式(slow mode)。設定值有:[Slow] [Fast] Link Frequency Select [Auto] 本項目為設定 QPI 連線頻率。設定值有:[Auto] [6.4 GT/s] [8.0 GT/s] [9.
4.6.
Memory Topology 顯示有關 DIMM 記憶體拓樸架構的群體資訊。 Memory Thermal 提供您進行溫度設定。 Set Throttling Mode [Disabled] 設定值有:[Disabled] [CLTT] [OLTT] OLLT Peak BW% [xxx] 提供您設定 OLTT 容許峰值頻寬。此單位為百分比且設定的有效數值範圍為從 25-100。 DIMM Tem Stat [xx] 提供您設定 DIMMTEMPSTAT 為 temp_mid 或 tem_hi。 Memory Power Savings Mode [Auto] 提供您設定 CKE 與其他相關的記憶體省電功能。設定值有:[Auto] [Disabled] [APD On] [User Defined] [Reserve] [Reserved] Memory Power Savings Advanced Options CK in SR [Auto] 設定值有:[Auto] [Driver] [Tri-State] [Pulled Low] Pulled High] MDLL Off [Auto]
Mem Electrical Throttling [Disabled] 本項目為設定 Memory Electical throttling 功能。設定值有:[Disabled] [Enabled] [Auto] Memory Map Channel Interleaving [Auto] 提供選擇不同的 c h a n n e l i n t e r l e a v i n g 設定。設定值有:[A u t o] [1-w a y Interleave] [2-way Interleave] [3-way Interleave] [4-way Interleave] Rank Interleaving [Auto] 選擇不同的 rank interleaving 設定。設定值有:[Auto] [1-way Interleave] [2-way Interleave] [4-way Interleave] [8-way Interleave] Memory RAS Configuration RAS Mode [Disabled] 啟用或關閉 RAS 模式。不支援啟用 Sparing 與 Mirr
4.6.
4.6.
PCH sSATA Configuration sSATA Controller [Enabled] 啟用或關閉 sSATA 控制器。設定值有:[Disabled] [Enabled] Configure sSATA as [AHCI] 提供您識別 SATA 埠為連接 Solid State Drive(SSD)硬碟或硬碟機'裝置。設定值 有:[IDE] [AHCI] [RAID] SATA Mode options SATA LED locate [Enabled] 若選擇啟用,會附加 LED/SGPIO 硬體。設定值有:[Disabled] [Enabled] Support Aggressive Link Power Management [Enabled] 啟用或關閉 Suport Aggressive Link Power (SALP) 管理功能。設定值有:[Disabled] [Enabled] SATA Port 1/ SATA Port 2/ SATA Port 3/ SATA Port 4 Port 1/ Port 2/ Port 3/ Port 4 啟用或關閉 SATA 連接埠。
PCH SATA Configuration SATA Controller [Enabled] 啟用或關閉 SATA 控制器。設定值有:[Disabled] [Enabled] Configure SATA as [AHCI] 提供您識別 SATA 埠為連接 Solid State Drive(SSD)硬碟或硬碟機'裝置。設定值 有:[IDE] [AHCI] [RAID] Support Aggressive Link Power Management [Enabled] 本項為啟用 Suport Aggressive Link Power (SALP) 管理功能。設定值有:[Disabled] [Enabled] SATA Port 1~6 Port 1/ Port 2/ Port 3/ Port 4/ Port 5/ Port 6 [Enabled] 啟用或關閉 SATA 連接埠。設定值有:[Disabled] [Enabled] 4-38 第四章:BIOS 程式設定
USB Configuration xHCI Mode [Auto] 啟用或關閉 xHCI 控制器的運作模式。設定值有:[Auto] [Disabled] [Enabled] USB Ports Per-Port Disable Control [Disabled] 提供您啟用或關閉所有的 USB 連接埠 1 至 8 。[Disabled] [Enabled] 以下的項目僅當 USB Ports Per-Port Disable Control 設為 [Enabled] 時才 會顯示。 USB Port #1/ #2/ #3/ #4/ #5/ #6/ #7/ #8 [Enabled] 設定值有:[Disabled] [Enabled] USB 3.
Platform Thermal Configuration PCH Thermal Device [Auto] 啟用或關閉 PCH Thermal Device (D31:F6)。設定值有:[Auto] [Disabled] [Enabled] Alert Enable Lock [Disabled] 提供您鎖定所有 Alert Enable 設定。設定值有:[Disabled] [Enabled] 4.6.
4.6.9 Server ME 設定 顯示在您系統上的 Server ME 技術的參數。 4.6.
4.
System Event Log 提供您變更 SEL 事件記錄設定。 SEL Components [Enabled] 開機過程時,啟用或關閉所有事件記錄(E v e n t L o g g i n g)功能。設定值有: 在 [Disabled] [Enabled] • 以下的項目僅當 SEL Components 設為 [Enabled] 時才會顯示。 • 所有變更的數值將會於重新開機後才套用。 Erase SEL [No] 提供您選擇清除 SEL 的選項。設定值有:[No] [Yes, On next reset] [Yes, On every reset] When SEL is Full [Do Nothing] 選擇當 SEL 滿載時的動作。設定值有:[Do Nothing] [Erase Immediately] Log EFI Status Codes [Error code] 關閉載入 EFI 狀態編碼,或僅載入錯誤編碼,或僅載入前行編碼,或兩者都載 入。設定值有:[Disabled] [Both] [Error Code] [Progress Code] 華碩 Z10PE-D8
Bmc network configuration 在此子選單裡的項目可以提供您設定 BMC 區域網路參數。 Configuration Address source DM_LAN1/LAN1 [Previous State] 選擇設定的網路通道的參數為靜態或動態(透過 BIOS 或 BMC)。未指定選項 將不會修改在 BIOS 裡的任何 BMC 網路參數。設定值有:[Previous State] [Static] [DynamicBmcDhcp] [DynamicBmcNonDhcp] View System Event Log 可以檢視系統事件記錄。 4-44 第四章:BIOS 程式設定
IPv6 BMC Network Configuration 本項目提供您設定有關 IPv6 BMC 網路的參數。 IPv6 Display Full Field [Enable] 顯示完整或簡要的 IPv6 欄位。設定值有:[Disable] [Enable] IPv6 Display Full Formula [Enable] 顯示完整或簡要的 IPv6 Formula。設定值有:[Disable] [Enable] IPv6 Display Letter Case [Upper Case] 顯示大寫或小寫字母。設定值有:[Lower Case] [Upper Case] IPv6 BMC Lan IP Address Source [Enable] 選擇設定的網路通道的參數為靜態或動態(透過 BIOS 或 BMC)。設定值有: [Unspecified] [Static] [Dynamic-Obtained by BMC running DHCP] 華碩 Z10PE-D8 WS 主機板使用手冊 4-45
4.8 事件記錄選單(Event Logs menu) 4.8.
Smbios Event Log Standard Settings Log System Boot Event [Disabled] 選擇啟用或關閉系統開機事件記錄。設定值有:[Enabled] [Disabled] 4.8.
4.9 監控選單(Monitor menu) 本選單顯示系統監控或電源狀態,並且提供您變更風扇設定。 往下捲動可以看到更多的項目。 CPU 1/2 Temperature [xxx℃/xxx℉] 本系統具備溫度感測器,可自動偵測並顯示目前主機板零組件與處理器的溫度。 CPU FAN1/2 Speed; FRNT FAN1–5 Speed; REAR FAN1/2 Speed [xxxx RPM] or [N/A] 為了避免系統因為過熱而造成損壞,本系統具備有處理器風扇、前置風扇與後置風 扇的轉速 RPM(Rotations Per Minute)顯示。若該欄位顯示為 [N/A],則表示風扇並 未連接至主機板上的該插座。 +VCCIO, VCORE1/2 Voltage, +VDDQ_AB Voltage, +VDDQ_CD Voltage, +VDDQ_ EF Voltage, +VDDQ_GH Voltage, +5VSB Voltage, +5V Voltage, 12V Voltage, +3.3V Voltage, VBAT Voltage, +3.
4.10 安全性選單(Security menu) 本選單可以讓您變更系統安全設定,並且提供您啟用或關閉安全開機(S e c u r e Boot)狀態與讓使用者設定系統模式(System Mode)狀態。 Administrator Password(設定系統管理員密碼) 當您設定系統管理員密碼後,建議您先登入您的帳戶,以免 BIOS 設定程式中的某 些資訊無法檢視或變更設定。 請依照以下步驟設定系統管理員密碼(Administrator Password): 1. 請選擇 Administrator Password 項目並按下 。 2. 由 Create New Password 視窗輸入欲設定的密碼,輸入完成時,請按下 。 3. 請再一次輸入密碼以確認密碼正確。 請依照以下步驟變更系統管理員密碼(Administrator Password): 1. 請選擇 Administrator Password 項目並按下 。 2. 由 Enter Current Password 視窗輸入密碼並按下 。 3.
User Password(設定使用者密碼) 當您設定使用者密碼後,你必需登入您的帳戶才能使用 BIOS 設定程式。使用者密 碼的預設值為 Not Installed,當您設定密碼後將顯示 Installed。 請依照以下步驟設定使用者密碼(User Password): 1. 請選擇 User Password 項目並按下 。 2. 由 Create New Password 視窗輸入欲設定的密碼,輸入完成時,請按下 。 3. 請再一次輸入密碼以確認密碼正確。 請依照以下步驟變更使用者密碼(User Password): 1. 請選擇 User Password 項目並按下 。 2. 由 Enter Current Password 視窗輸入密碼並按下 。 3. 由 Create New Password 視窗輸入新密碼,輸入完成按下 。 4.
Key Management 本項目僅當 Secure Boot Mode 設定為 [Custom] 時才會顯示,提供您修改 Secure Boot(安全開機)變量與設定 Key Management(密鑰管理)頁面。 Default Key Provision [Disabled] 設定值有:[Disabled] [Enabled] Enroll All Factory Default Keys 若您想要安裝系統預設安全變量,本項目將會進行詢問。若您想要載入預設的 安全變量,請選擇 Yes;否則請選擇 No。 Save All Secure Boot Variables 若您想要儲存所有安全變量,本項目將會進行詢問。選擇 Yes 進行儲存;或選 擇 No 取消。 P latform Key (PK)/ Key Exchange Key (KEK)/ Authorized Signatures (DB)/ Authorized TimeStamps (DBT)/ Forbidden Signatures (DBX) 設定值有:[Delete] [Set New] [Append] 華碩 Z10PE
4.
• 若要在開機過程中選擇開機裝置,請於開機看到 ASUS 圖示時按下 鍵 • 您可以在 POST(開機自我測試)時,按下 鍵進入 Windows 作 業系統的安全模式(Safe Mode)。 Network Device BBS Priorities 這些項目僅在當已連接 SATA 光碟機或硬碟機至 SATA 連接埠才會顯示,且提供 您在此設定 SATA 裝置的開機順序。 4.
4.
Restore Defaults 本項目提供您還原或載入所有選項的預設值。在選擇本項目後,將會出現一個確認 對話視窗,請選擇 Yes 以載入有效的預設值。 Save as User Defaults 根據使用者預設(User Defaults)儲存變更。 Restore User Defaults 還原使用者預設(User Defaults)至所有設定選項。 Boot Override 這些項目會顯示可用的裝置。顯示在畫面中的裝置則是根據安裝在系統裡的裝置而 定,點選任一個項目可以設定該項目裡所列裝置的開機順序。 Launch EFI Shell from filesystem device 本項目可以讓您由含有資料系統的裝置中啟動 EFI Shell(shellx64.
4-56 第四章:BIOS 程式設定
第五章: RAID 磁碟陣列設定 在本章節中,我們將介紹伺服器內所支 援的磁碟陣列的設定與說明。 5
5.1 RAID 功能設定 本伺服器主機板支援以下 RAID 設定: 本主機板可支援以下 SATA RAID 方案: • LSI MegaRAID software RAID 設定程式支援 RAID 0、RAID 1 與 RAID 10(適用 於 Linux 與 Windows 作業系統)。 • Intel Rapid Storage Technology enterprise SATA Option ROM Utility 技術支援 RAID 0、RAID 1、RAID 10 與 RAID 5(僅適用於 Windows 作業系統)。 5.1.
5.1.2 安裝硬碟機 本主機板支援 Serial ATA 硬碟。為了最佳的效能表現,當您要建立陣列模式設定 時,請盡可能採用具備相同型號與容量的硬碟機。 請依照以下安裝方式來建構 SATA RAID 磁碟陣列: 1. 按照說明將 SATA 硬碟安裝至硬碟槽中。 2. 將 SATA 訊號線連接到 SATA 硬碟後方的訊號線連接插座。 3. 將 SATA 電源線連接到 SATA 硬碟後方的電源連接孔。 5.1.3 在 BIOS 程式中設定 RAID 在您開始建立陣列之前,您必須先在 BIOS 程式設定中設定對應的 RAID 選項。請 依照下列步驟進行操作︰ 1. 在開機後系統仍在進行開機自我測試(Power-On Self Test,POST)時,按下 按鍵進入 BIOS 設定程式。 2. 進入 Advanced 選單 > PCH SATA Configuration 後,按下 鍵。 3. 將 SATA Mode 選項設定為 [RAID Mode]。 4.
5.2 LSI Software RAID 設定程式 LSI MegaRAID Software RAID 設定程式可以提供您建立 RAID 0、RAID 1 或 RAID 10 設定,此為經由主機板上內建的南橋晶片與連接的 SATA 硬碟機來建立。 請依照以下的步驟來開啟 LSI MegaRAID software RAID 設定程式: 1. 在安裝好所有的 SATA 硬碟機後,開啟系統。 2. 當在自我測試進行時,LSI MegaRAID software RAID 設定程式會自動偵測所安裝 的 SATA 硬碟機與顯示現存的 RAID 設定。請按下 + 鍵來進入此程 式。 LSI MegaRAID Software RAID BIOS Version A.
選單項目 Configure Initialize 說明 您可以透過 Easy Configuration 或 New Configuration 功能來建 立 RAID 0、RAID 1 或 RAID 10 設定。這個選單也可以讓您檢 視、新增或刪除 RAID 的設定,或是選擇開機的硬碟裝置 允許您初始已建立 RAID 設定的虛擬磁碟機 Objects 允許您初始虛擬磁碟機或變更虛擬磁碟的參數 Rebuild 允許您重建失效的磁碟機 Check Consistency 提供您檢查已建立 RAID 設定的虛擬磁碟機的資料一致性 5.2.
2. 在 ARRAY SELECTION MENU 畫面中,顯示目前連接且可用的 SATA 硬碟機有多 少部。選擇您要進行設定 RAID 的硬碟機,然後按下 <空白> 鍵。當選擇時,硬 碟指示會從 READY 變更成 ONLIN A[X] - [Y],而 X 所代表的是任何數字,且 Y 表示硬碟裝置的數字代號。 LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010 BIOS Version A.10.09231523R Easy Configuration - ARRAY SELECTION MENU Management Menu Configure Initialize Objects Rebuild Check Consistency Port # 2 DISK PORT # 0 ONLIN A00-00 1 ONLIN A00-01 2 READY 3 READY 74.74GB HDS728080PLA380 05.
5. 再次按 鍵,這時會在 Virtual Drive 選單中看到虛擬磁碟的資訊,並且可以 讓您進行變更虛擬磁碟機的參數。 LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010 BIOS Version A.10.09231523R LD Virtual Drive(s) Configured Easy -#Stripes ARRAY SELECTION MENU RAID Configuration Size StripSz Management Menu Configure 0 Initialize Objects Rebuild Check Consistency 1 148.
8. 從 Virtual Drive 子選單裡選擇 Units,然後按下 鍵。 9. 從選單裡選擇 units 的 virtual drive 大小,然後按下 鍵。 LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010 BIOS Version A.10.09231523R LD Virtual Drive(s) Configured Easy -#Stripes ARRAY SELECTION MENU RAID Configuration Size StripSz Management Menu Configure 0 Initialize Objects Rebuild Check Consistency 1 148.
12. 當完成所選擇的虛擬磁碟裝置的設定時,請選擇畫面中的 Accept 後按下 鍵。 LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010 BIOS Version A.10.09231523R LD Virtual Drive(s) Configured Easy -#Stripes ARRAY SELECTION MENU RAID Configuration Size StripSz Management Menu Configure 0 Initialize Objects Rebuild Check Consistency 1 148.
使用 New Configuration 設定 當一個 RAID 設定已經存在,使用 New Configuration 指令來清除存在 的 RAID 設定資料。若您不要刪除已存在的 RAID 設定,使用 View/Add Configuration 選項來檢視或建立其他的 RAID 設定。 請依以下步驟,使用 New Configuration(新增設定)模式來建立一個 RAID 設定: 1. 進入主選單畫面後,選擇 Configure > New Configuration 項目,然後按 鍵繼續。 LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010 BIOS Version A.10.
5.2.2 新增或檢視一個 RAID 設定 您可以使用 View/Add Configuration 功能來新增一個新的 RAID 或者是檢視一個現 存的 RAID 設定。 新增一個 RAID 設定 請依照以下步驟新增一個 RAID 設定: 1. 進入主選單畫面後,選擇 Configure > View/Add Configuration 項目,然後按 鍵繼續。 LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010 BIOS Version A.10.
5.2.3 將虛擬磁碟初始化 當您完成建立 RAID 設定時,您必須將虛擬磁碟做初始化。您可以透過主選單畫面 中的 Initialize 或 Objects 選項,進行虛擬磁碟初始化的動作。 使用 Initialize 指令設定 請依照以下步驟,使用 Initialize(初始化)功能: 1. 進入主選單畫面後,選擇 Initialize 選項,然後按下 鍵。 LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010 BIOS Version A.10.09231523R Management Menu Configure Initialize Objects Rebuild Check Consistency Initialize VD(s) Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option 2.
3. 當出現提示時,按下 <空白> 鍵後,從 Initialize? 的對話框中選擇 Yes,然後按 下 鍵。您也可以透過按下 鍵來初始化硬碟裝置,而不需要再做任 何確認動作。 LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010 BIOS Version A.10.09231523R Management Menu Configure Initialize Objects Rebuild Check Consistency LD 0 Virtual Drive(s) Configured Easy -#Stripes ARRAY SELECTION MENU RAID Configuration Size StripSz 1 148.
使用 Objects 指令設定 請依照以下步驟使用 Objects 功能: 1. 進入主選單畫面,選擇 Objects > Virtual Drive 選項後按下 鍵。 LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010 BIOS Version A.10.09231523R Objects Management Menu Adapter Configure Virtual Drive Initialize Physical Drive Objects Rebuild Check Consistency Change VD Parameters Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option 2.
3. 從彈出的子選單中選擇 Initialize 選項,然後按下 鍵開始進行硬碟初始 化。 LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010 BIOS Version A.10.09231523R Objects Virtual Drive(1) Virtual Drive 0 Management Menu Adapter Configure Virtual Drive Initialize Physical Drive Objects Virtual Drive(0) Rebuild Initialize Check Consistency Check Consistency View/Update Parameters Initialize VD Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option 4.
5.2.4 重新建立損壞的硬碟 您可以採用手動的方式重新建立損壞的硬碟裝置,透過使用主選單畫面中的 Rebuild 指令來達成。 請依照以下步驟重新建立損壞的硬碟: 1. 進入主選單畫面後,選擇 Rebuild 選項,然後按下 鍵。 LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010 BIOS Version A.10.09231523R Management Menu Configure Initialize Objects Rebuild Check Consistency Rebuild VD(s) Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option 2.
3. 當選擇欲重新建立的硬碟後並按下 鍵,所選擇的硬碟裝置則會顯示 RBLD 的指示。當出現對話框時,請按下 來重新建立硬碟裝置。 LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010 BIOS Version A.10.09231523R REBUILD - PHYSICAL DRIVES SELECTION MENU Management Menu Configure PORT # Initialize 0 ONLIN A00-00 Objects 1 FAIL A00-01 Rebuild Rebuilding of Drive Will Take A Few Minutes.
5.2.5 檢查硬碟資料的一致性 您可以檢查與核對所選擇硬碟裝置中資料一致性的正確性。這個工具程式自動偵測 或發現並修正資料冗位的任何差異,選擇 Objects > Adapter 選項來進行。 Check Consistency(一致性檢查)指令可用在包含 RAID 1 與 RAID 10 設定下的虛擬磁碟機。 使用 Check Consistency 指令設定 請依照以下步驟,使用 Check Consistency 指令檢查資料的一致性: 1. 進入主選單畫面選擇 Check Consistency 選項後,按下 鍵。 LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010 BIOS Version A.10.
3. 當出現提示時,按下 <空白> 鍵並從 Consistency Check? 的對話框中選擇 Yes, 然後按下 鍵。 LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010 BIOS Version A.10.
使用 Objects 指令 請依照以下的步驟,使用 Objects 指令檢查資料的一致性: 1. 進入主選單畫面(Management Menu)後,選擇 Objects 中的 Virtual Drive 選 項。 2. 使用方向鍵選擇您所要檢查的虛擬磁碟機後,按下 鍵。 3. 從子選單中選擇 Check Consistency 後,按下 鍵。 4. 當出現對話框時,使用方向鍵選擇 Yes 後,開始進行檢查硬碟。 5.
5.2.6 刪除一個 RAID 設定 您可以依照以下步驟刪除一個 RAID 設定: 1. 進入主選單畫面選擇 Configure > Clear Configuration 後按下 鍵。 LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010 BIOS Version A.10.09231523R Configuration Menu Easy Configuration Management MenuNew Configuration Configure View/Add Configuration Initialize Clear Configuration Objects Select Boot Drive Rebuild Check Consistency Clear Existing Configuration Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option 2.
5.2.7 從 RAID 設定中選擇開機磁碟 在您要設定選擇開機磁碟前,您必須已經建立好一個新的 R A I D 設定。請參考 6.2.1 使用 New Configuration 設定 的說明。 您可以依照以下的步驟,來刪除一個 RAID 設定: 1. 進入主選單畫面選擇 Configure > Select Boot Drive 後,按下 鍵。 LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010 BIOS Version A.10.
5.2.8 開啟 WriteCache 在您完成建立一個 RAID 設定後,您可以手動啟用 RAID 控制功能的 WriteCache 選 項,來新增資料傳輸時的效能。 當您開啟 WriteCache 功能時,在硬碟傳輸或交換資料時若發生電源中 斷,可能會導致檔案遺失。 建議在 RAID 1 與 RAID 10 設定上使用 WriteCache 功能。 您可以依照以下步驟啟用 WriteCache 功能: 1. 當進入主選單畫面後,選擇 Objects > Adapter 後,按下 鍵顯示介面的屬 性。 2. 選擇 Disk WC 後,按下 鍵開啟選項。 LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010 BIOS Version A.10.
5.3 I ntel ® Rapid Storage Technology enterprise SATA Option ROM 工具程式 Intel® Rapid Storage Technology enterprise SATA Option ROM 工具程式經由南橋晶 片的支援,可讓您使用安裝在系統中的 Serial ATA 硬碟機建立 RAID 0、RAID 1、 RAID 10(1+0)與 RAID 5 設定。 在您進行前,請確認您已裝妥 Serial ATA 硬碟機,並且調整好正確的主 機板跳線設定,然後在 BIOS 程式中設定正確的 SATA 模式。您可以參考 5.1.2 ~ 5.1.4 節的內容,以了解更多相關的說明。 請依照下列步驟,進入 Intel® Rapid Storage Technology enterprise SATA Option ROM 程式: 1. 啟動您的電腦。 2.
5.3.1 建立 RAID 設定 請依照下列步驟建立一個 RAID 設定: 1. 從主選單畫面中選擇 1. Create RAID Volume,然後按下 <Enter> 鍵,會出現如 下圖所示的畫面。 2. 為您的 RAID 鍵入一個名稱,然後按下 鍵。 Intel(R) Rapid Storage Technology enterprise - SATA Option ROM - 3.6.0.1023 Copyright(C) 2003-12 Intel Corporation. All Rights Reserved. [ CREATE VOLUME MENU ] Name: Volume0 RAID Level: RAID0(Strips) Disks: Select Disks Strip Size: 128KB Capacity: 0.
6. 使用向上/向下方向鍵來選擇磁碟陣列的 stripe 大小(僅支援 RAID 0、10 與 5 設 定時使用),然後按下 鍵。其數值可由 4KB 遞增至 128KB。本項目建議 依照以下的使用需求,以進行正確的設定。 ·RAID 0:128KB ·RAID 10:64KB ·RAID 5:64KB 若您所使用的是伺服器系統,建議選擇較低的陣列區塊大小;若是用於處 理音樂、影像剪輯的多媒體電腦系統,則建議選擇較高的陣列區塊大小。 7. 選擇 Capacity 項目,輸入您所要的陣列容量,接著按下 鍵。本項目預設 值是採用最高可容許的容量。 8. 在 Create Volume 的提示對話框中,再按下 鍵來建立磁碟陣列,接著便 會出現如下圖的警告訊息畫面。 9. 按下 來建立陣列並回到主選單,或是按下 鍵,回到 CREATE ARRAY (建立陣列)選單。 WARNING: ALL DATA ON SELECTED DISKS WILL BE LOST.
5.3.2 刪除 RAID 磁區 在操作此功能時請務必非常小心,所有在硬碟中的資料將被刪除。 請依照下列步驟刪除 RAID 磁區︰ 1. 選擇 2. Delete RAID Volume 選項後,按下 鍵進入設定畫面。 2. 使用向上、向下方向鍵選擇您所要刪除的陣列後,按下 鍵刪除 RAID 磁 區。在按下確認後,會出現如下圖所示的確認畫面。 Intel(R) Rapid Storage Technology enterprise - SATA Option ROM - 3.6.0.1023 Copyright(C) 2003-12 Intel Corporation. All Rights Reserved. [ DELETE VOLUME MENU ] Name Volume0 Level RAID0(Stripe) Drives 2 Capacity 298.
5.3.3 重新設定硬碟為非陣列硬碟 請注意!當您將 RAID 陣列硬碟設定為無 RAID 陣列狀態時,所有磁碟陣 列中的資料與陣列本身的結構資料都將被移除。 請依照下列步驟重新設定 RAID 硬碟。 1. 選擇選項 3. Reset Disks to Non-RAID 後,按下 鍵以顯示以下的畫面。 2. 使用向上/向下方向鍵選擇您所想要重新設定的所有 RAID 硬碟組,並按下 <空白> 鍵確認。再按下 鍵重新設定 RAID 硬碟組。接著會顯示一個確認訊息。 [ RESET RAID DATA ] Resetting RAID disk will remove its RAID structures and revert it to a non-RAID disk. WARNING: Resetting a disk causes all data on the disk to be lost.
5.3.4 退出 Intel Rapid Storage Technology enterprise 程式 請依照下列步驟退出公用程式︰ 1. 在公用程式主選單中,請選擇 4. Exit 然後按下 鍵,會出現如下所示的畫 面。 [ CONFIRM EXIT ] Are you sure you want to exit? (Y/N): 2. 請按下 鍵以退出程式,或按下 鍵回到功能設定主選單。 5.3.5 重建 RAID 設定 此選項支援 RAID1、RAID 5 和 RAID 10 設定。 使用非 RAID(Non-RAID)硬碟重建 RAID 設定 若有任何在 RAID 1 陣列設定中的 SATA 硬碟發生損壞時,系統會在開機自我偵測 (POST)進行時,顯示該 RAID 狀態為“Degraded”,您可以使用其他已經安裝的非 RAID 硬碟來重建該 RAID 設定。 請依照以下步驟,使用非 RAID(Non-RAID)硬碟重建 RAID 設定: 1.
3. 選定之後,程式會立即開始進行重建,並且顯示該 RAID 的狀態為“Rebuild”。 Intel(R) Rapid Storage Technology enterprise - SATA Option ROM - 3.6.0.1023 Copyright(C) 2003-12 Intel Corporation. All Rights Reserved. 1. Create RAID Volume 2. Delete RAID Volume RAID Volumes: ID Name 1 Volume0 [ MAIN MENU ] 3. Reset Disks to Non-RAID 4. Exit [ DISK/VOLUME INFORMATION] Level1 RAID1(Mirror) Physical Devices: Port Drive Model 1 ST3160812AS 2 ST3160812AS Strip N/A Serial # 9LS0F4HL 3LS0JYL8 Size 149.0GB Size 149.0GB 149.
5.3.6 在 BIOS 程式中設定開機陣列 當您使用 Intel® Rapid Storage Technology enterprise SCU/SATA Option ROM 建立多 重 RAID(multi-RAID)時,您可以將您所設定的 RAID 陣列於 BIOS 程式中設定開機 優先順序。 請依照以下的步驟,於 BIOS 程式中設定開機陣列: 請從硬碟中至少設定一個開機陣列。 1. 請在開機自我偵測(POST) 時,按下 鍵進入 BIOS 程式設定畫面。 2. 進入 Boot 選單,然後選擇 Boot Device Priority 項目。 3. 使用向上/向下方向鍵,選擇開機順序後按下 鍵,請參考 4.10 開機選單 (Boot Menu)的說明。 4. 從 Exit 選單中,選擇 Exit & Save Changes,然後按下 鍵。 5.
5.4 I ntel® Rapid Storage Technology enterprise 工具程式 (Windows) The Intel® Rapid Storage Technology enterprise 工具程式提供您使用安裝在系統中 的 Serial ATA / SAS 硬碟裝置建立 RAID 0、RAID 1、RAID 10(1+0)與 RAID 5 設 定。 在 Windows 作業系統環境中,進入 Intel® Rapid Storage Technology enterprise 程 式: 1. 開機並進入作業系統桌面。 2.
5.4.1 建立 RAID 設定 請依照以下步驟建立 RAID 設定: 1. 在前面的主選單畫面中,點選 Create Volume 並選擇 volume 類型。 2. 點選 Next 繼續。 3. 輸入欲建立 RAID 設定的名稱,然後選擇陣列要用的磁碟。 4. 選擇 Volume Size 欄位,您可以拖曳畫面中的橫桿以決定容量大小。 5.
6. 確認建立,請點選 Create Volume 繼續。 建立的過程會因數量與容量不同而需要等候一段時間,在此期間,您可 以繼續使用其他的應用程式。 7.
5.4.2 變更 Volume 類型 當您完成建立 RAID 設定時,您可以在 Volume Properties 欄位中檢視或變更裡頭 的各個項目。 您可以依據以下步驟變更 Volume Properties 的類型: 1. 在 Volumes 欄位中點選您想要變更的 SAS 或 SATA 陣列。 2 然後在 Volume Properties 欄位選擇 Type:RAID 1 Change type。 3. 如有需要,您也可以在此變更 Name、Select the new volume type 與Select additional disks to include in the new volume 這幾個項目。 4.
5.4.3 刪除 Volume 在操作此功能時請務必非常小心,所有在硬碟中的資料將被一併刪除, 如有需要請先備份檔案。 請依照以下步驟刪除 Volume: 1. 在主選單裡,點選在 V o l u m e 欄位中欲刪除的 V o l u m e(如以下畫面中顯示的 Volume_0000)。 2. 然後點選 Volume Properties 欄位中的 Delete volume,則會顯示如下的畫面。 3.
5.4.
5-38 第五章:RAID 磁碟陣列設定
第六章: 安裝驅動程式 在本章節中,我們將介紹主機板所支援的 相關驅動程式的安裝與設定說明。 6
6.1 安裝 RAID 驅動程式 當您在系統中建立好 RAID 陣列模式後,就可以開始安裝作業系統至獨立的硬碟裝 置或具開機功能的陣列上。本章節將介紹如何在安裝作業系統的過程中,控制 RAID 的驅動程式。 6.1.1 建立一張 RAID 驅動程式磁片 您必須使用其他的電腦主機,並搭配系統/主機板所附的公用程式光碟片 中的軟體,來建立此張 RAID 驅動程式磁片。 當您使用 LSI Software RAID Configuration 工具程式建立 RAID 設定, S A T A 光碟機的開機次序將需透過手動調整。否則,系統將不會透過 SATA 光碟機開機。 在 Windows 系統環境下,建立一張含有 RAID 驅動程式的磁碟片: 1. 進入作業系統。 2. 在光碟機中放入本系統/主機板的驅動及公用程式光碟。 3. 進入 Make Disk 選單,選擇您所要建立的 RAID 驅動程式種類。 4. 然後放入一張已經格式化的空白磁碟片於軟碟機中。 5.
6.1.2 安裝 RAID 驅動程式 在 Windows® Server 2008 R2 系統安裝過程中安裝 您可以在 Windows® Server 2008 R2 系統安裝過程中安裝 RAID 驅動程式: 1. 使用 Windows® Server 2008 R2 作業系統安裝光碟開機,並依照畫面的指示開始 安裝作業系統。 2. 當畫面跳出選擇安裝的類型時,請選擇 Custom(advanced)。 3.
6-4 4. 然後顯示訊息,提醒您放入 RAID 控制器驅動程式檔案。若您的系統裡有僅只有 一部光碟機,請先將 Windows 作業系統安裝光碟退出,並放入驅動與公用程式 DVD 光碟,然後點選 Browse(瀏覽)。 5. 找到存放在驅動與公用程式光碟內的驅動程式,然後點選 OK 繼續。 6. 從清單中選擇您所要安裝的 RAID 控制器驅動程式,然後點選 Next。 7. 當系統載入 R A I D 驅動程式後,請取出主機板驅動與公用程式光碟 並再放 入 Windows Server 作業系統安裝光碟,選擇驅動程式安裝至 Windows 並點選 Next。 8.
Red Hat® Enterprise Linux 5.x 作業系統 請依以下步驟在 Red Hat® Enterprise 作業系統安裝過程中安裝 RAID 驅動程式: 1. 使用 Red Hat® 作業系統安裝光碟片啟動系統。 2. 然後於 boot: 後,輸入 linux dd,再按下 鍵。 - To install or upgrade in graphical mode, press the key. - To install or upgrade in text mode, type: linux text . - Use the function keys listed below for more information. [F1-Main] [F2-Options] [F3-General] [F4-Kernel] [F5-Rescue] boot: linux dd 3.
5. 當詢問您是否增加其他額外的 R A I D 控制器驅動程式時,選擇 N o,然後按下 鍵。 More Driver Disks? Do you wish to load any more driver disks? Yes 6. 接著請依照系統的提示繼續完成作業系統的安裝。 7. 在安裝完成後,請先不要點選 Reboot。請先按下 + + 鍵,從圖 形介面切換至指令列介面。 8. 若您所使用的是標準軟碟機,請在指令列介面輸入以下的指令執行 replace_ahci. sh: mkdir /mnt/driver mount /dev/fd0 /mnt/driver cd /mnt/driver sh replace_ahci.
Red Hat® Enterprise Linux OS 6.x 作業系統 在 Red Hat® Enterprise 作業系統環境下安裝 LSI MegaRAID 控制器驅動程式: 1. 將系統透過 Red Hat® 作業系統安裝光碟開機。 2. 按下 鍵編輯選項。 3.
4. 當系統詢問您若要透過磁碟片安裝時,請按下 鍵選擇 Y e s ,然後按下 鍵繼續。 Main Menu Do you have a driver disk? Yes 5. No 當詢問驅動程式磁碟來源時,請按下 鍵切換選擇來源裝置。接著再使用 鍵移至 OK 處,然後按下 鍵。 Driver Disk Sou8rce You have multiple devices which could serve as source for a driver disk.
6. 當出現此對話框時,請在 USB 介面軟碟機中放入 Red Hat Enterprise 的 RAID 驅 動程式磁片,並選擇 OK,然後按下 鍵。 Insert Driver Disk Insert your driver disk into /dev/sdb and press “OK” to continue. OK Back 此時會開始安裝 RAID 驅動程式至系統中。 7. 當詢問您是否增加其他額外的 R A I D 控制器驅動程式時,選擇 N o,然後按下 鍵。 More Driver Disks? Do you wish to load any more driver disks? Yes 8.
準備 Linux 驅動程式 請準備另一部裝有使用 Linux 作業系統的電腦,以建立 RAID 驅動程式。 當建立 RAID 驅動程式時,您可以參考以下的方式使用 64位元 SUSE Linux 系統來建立一張 64位元 RAID 驅動程式,以供 SUSE11 sp1 作業系統使用。 1. 將映像檔複製到 Linux 系統中。 範例:megasr-15.00.0120.2012-1-sles11-ga-x86_64.img 2. 新增一個資料夾。 範例:image 3. 使用以下的指令,將映像檔載入映像檔資料夾中: mount -o loop [image file name] image 範例:mount -o loop megasr-15-15.00.0120.2012-1-sles11-ga-x86__64.img image 4. 將映像檔資料夾標示為 01,並複製至一個 FAT32 格式的 USB 儲存裝置中。 5.
在 SUSE Linux 11 作業系統下安裝 請依照以下步驟,於 SUSE Linux Enterprise Server 作業系統下安裝 RAID 控制晶片 的驅動程式: 1. 使用 SUSE 作業系統安裝光碟開機。 2. 使用方向鍵從 Boot Options 畫面中選擇 Installation 選項。 3.
4. 當出現對話框時,請在軟碟機中放入 RAID 驅動程式磁碟片,並在 Boot Options 欄位中輸入 brokenmodules=ahci,然後按下 鍵。 5. 當出現對話框時,選擇在安裝畫面中的 sda(選擇 USB 介面軟碟機)這項,接著 選擇 OK,然後按下 鍵。 Please choose the Driver Update medium. sda: USB Floppy other device OK 6.
6.2 安裝管理應用與工具程式 在主機板所附的應用程式與驅動程式光碟片中,包含有驅動程式、管理應用程式, 以及一些工具程式,讓您可以搭配在主機板上操作使用。。 1. 驅動與公用程式光碟內容若有變更,恕不另行通知。請上網至華碩網 站(www.asus.com) 以取得最新的軟體和程式更新資訊。 2. 驅動與公用程式光碟支援 Windows ® Server 2008 R2 和 Windows ® Server 2012 版本的作業系統。 6.3 執行驅動與公用程式光碟 若“自動安插通知”功能開啟,當您將驅動與公用程式光碟放入光碟機時,光碟會 自動顯示主選單。預設情況下將顯示驅動程式主選單。 若視窗並未自動出現,那麼請瀏覽驅動及公用程式 D V D 光碟的檔案內 容,找到 BIN 目錄中的 ASSETUP.EXE 程式,並點選 ASSETUP.EXE 主程 式來開啟選單畫面。 6.3.
6.3.2 工具軟體選單 工具軟體選單將顯示主機板支援的工具軟體程式。 6.3.
6.3.4 使用手冊選單 使用手冊選單提供了到 Broadcom NetXtreme II Network Adapter 使用手冊的連結。 在您的作業系統中安裝一個網路瀏覽器以查看使用手冊。 6.3.
6.4 安裝驅動與公用程式 本驅動及工具程式光碟裡提供您主機板相關的驅動程式、管理應用程式與工具程 式,可以讓您將主機板功能最佳化。 6.4.1 使用華碩 InstAll 應用程式 本節將介紹如何使用華碩 InstAll 進行安裝驅動及公用程式,透過有安裝指導精靈 來協助您以極少的步驟便能輕鬆地安裝驅動及公用程式。 請依照以下步驟使用華碩 InstAll 進行安裝驅動及公用程式: 1. 開機,並使用 Administrator(主管理者)權限登入 Windows 系統。 2. 於光碟機中放入主機板所附的驅動及公用程式光碟,若您的系統已經啟動了光碟 機“自動安插通知”的功能,那麼稍後一會光碟會自動顯示 Drivers 選單(驅動 程式選單)視窗。 若視窗並未自動出現,那麼請瀏覽驅動及公用程式 D V D 光碟的檔案內 容,找到 BIN 目錄中的 ASSETUP.EXE 程式,並點選 ASSETUP.EXE 主程 式來開啟選單畫面。 3.
4. 勾選 Install drivers and recommended tools automatically from InstAll (recommended) ,然後點選 OK 開啟 ASUS InstAll 主選單。 當您想要安裝已選定的驅動或公用程式時,請勾選 C u s t o m i z e t h e installation of drivers or Install drivers only。當選擇這兩個選項的其中 一項時,您必須指定想要安裝的驅動或公用程式。 5.
6. 當完成安裝時請點選 OK。 6.4.2 安裝驅動或公用程式 本節為介紹有關如何從驅動及公用程式 DVD 光碟裡安裝特定的驅動或公用程式。 請依照以下步驟安裝驅動或公用程式: 1. 開機,並使用 Administrator(主管理者)權限登入 Windows 系統。 2. 於光碟機中放入主機板所附的驅動及公用程式光碟,若您的系統已經啟動了光碟 機“自動安插通知”的功能,那麼稍後一會光碟會自動顯示 Drivers 選單(驅動 程式選單)視窗。 若視窗並未自動出現,那麼請瀏覽驅動及公用程式 D V D 光碟的檔案內 容,找到 BIN 目錄中的 ASSETUP.EXE 程式,並點選 ASSETUP.EXE 主程 式來開啟選單畫面。 3.
以下表格為顯示元件或裝置,與其需要從驅動及公用程式 DVD 光碟裡進 行安裝的驅動程式。 元件 / 裝置 使用驅動及公用程式 DVD 光碟需要安裝的程式 .Intel Chipset Device Software 1. Intel 晶片組 . Intel I350-AM4 / I350-AM2 / I210 / X540-BT2 Gigabit Adapters Drivers .Intel C610 MEI Null HECI Driver . Intel(R) C610 series Chipset sSATA AHCI Controller Driver 2. VGA 顯示卡 .ASPEED AST2300 / AST2400 Display Driver 3. USB 控制器 . ASMedia ASM1042 / ASM1142 USB 3.0 Host Controller Driver 4. 音效功能 .Realtek 高傳真音效驅動程式 4. 請依照畫面的操作指示以完成軟體的安裝。 5.
6.5 執行應用程式 本節提供有關主機板產品所附的公用程式資訊,並包含有關如何安裝這些程式後啟 動,以及使用應用程式的詳細步驟。 6.5.1 Ai Charger+ 這個程式可以對連接在 USB 連接埠上的可攜式 BC 1.1* 行動裝置進行快速充電, 並且充電速度較標準 USB 裝置快三倍**。 • *請確認您的 USB 裝置製造商是否完整支援或相容 BC 1.1(Battery Charging Specification 1.
6.5.
6-22 第六章:安裝驅動程式
附錄: 相關資訊 本章包含安裝主機板時可以參考的相關 資訊與音效輸入/輸出埠連接設定說明。 A
A.
A.2 音效輸出/輸入連接圖示說明 連接耳機與麥克風 連接立體聲喇叭 連接 2.1 聲道喇叭 連接 4.
連接 5.1 聲道喇叭 若為使用 Windows 8.1 平台,在 6 聲道音效設定中,灰色的音效連接埠 為提供側邊聲道喇叭輸出使用。 連接 7.
華碩的連絡資訊 華碩電腦公司 ASUSTeK COMPUTER INC.(台灣) 市場訊息 技術支援 地址: 台灣臺北市北投區立德路 150 號 4 樓 電話:+886-2-2894-3447 傳真:+886-2-2890-7798 網址:http://www.asus.com/tw/ 電話: +886-2-2894-3447(0800-093-456) 線上支援: https://www.asus.com/support/ Product/ContactUs/Services/ questionform/?lang=zh-tw 華碩電腦公司 ASUSTeK COMPUTER INC.(亞太地區) 市場訊息 技術支援 地址: 台灣臺北市北投區立德路 150 號 4 樓 電話:+886-2-2894-3447 傳真:+886-2-2890-7798 網址:http://www.asus.com 電話:+86-21-38429911 傳真: +86-21-58668722, ext. 9101# 線上支援: https://www.asus.
DECLARATION OF CONFORMITY Per FCC Part 2 Section 2. 1077(a) Asus Computer International Responsible Party Name: 800 Corporate Way, Fremont, CA 94539. Address: Phone/Fax No: (510)739-3777/(510)608-4555 hereby declares that the product Product Name : Motherboard Model Number : Z10PE-D8 WS Conforms to the following specifications: FCC Part 15, Subpart B, Unintentional Radiators Supplementary Information: This device complies with part 15 of the FCC Rules.