Motherboard Z9PE-D16
E6889 First Edition V1 December 2011 Copyright © 2011 ASUSTeK COMPUTER INC. All Rights Reserved. No part of this manual, including the products and software described in it, may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language in any form or by any means, except documentation kept by the purchaser for backup purposes, without the express written permission of ASUSTeK COMPUTER INC. (“ASUS”).
Contents Contents....................................................................................................... iii Notices......................................................................................................... vii Federal Communications Commission Statement............................ vii Canadian Department of Communications Statement...................... vii REACH ...........................................................................................
Contents 2.5.3 Interrupt assignments.................................................... 2-17 2.5.5 PCI Express x16 slot (x8 link)........................................ 2-17 2.5.4 2.5.6 2.5.7 2.5.8 2.6 2.7 2.5.9 2.7.1 3.2.1 Powering up Using the OS shut down function..................................... 3-4 Using the dual function power switch............................... 3-4 BIOS setup ASUS CrashFree BIOS 3 utility....................................... 4-3 4.1.3 BUPDATER utility..........
Contents 4.4.2 CPU Power Management Configuration........................ 4-13 4.4.4 PCH SATA Configuration............................................... 4-21 4.4.3 4.4.5 4.4.6 4.4.7 4.4.8 4.4.9 4.4.10 4.4.11 4.4.12 4.4.13 4.4.14 4.4.15 4.4.16 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.4.17 PCH SCU SAS Configuration........................................ 4-22 PCI Subsystem Settings................................................ 4-23 Onboard LAN Configuration...........................................
Contents 5.2.5 Checking the drives for data consistency...................... 5-19 5.2.7 Selecting the boot drive from a RAID set....................... 5-23 5.2.6 5.3 5.2.8 Deleting a RAID configuration........................................ 5-22 Enabling WriteCache..................................................... 5-24 Intel Rapid Storage Technology enterprise SCU/SATA Option ROM Utility...................................................................... 5-25 ® 5.3.1 Creating a RAID set...
Notices Federal Communications Commission Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: • • This device may not cause harmful interference, and This device must accept any interference received including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
Safety information Electrical safety • • • • • • To prevent electrical shock hazard, disconnect the power cable from the electrical outlet before relocating the system. When adding or removing devices to or from the system, ensure that the power cables for the devices are unplugged before the signal cables are connected. If possible, disconnect all power cables from the existing system before you add a device.
About this guide This user guide contains the information you need when installing and configuring the motherboard. How this guide is organized This user guide contains the following parts: • • • • • • • Chapter 1: Product introduction This chapter describes the features of the motherboard and the new technologies it supports. Chapter 2: Hardware information This chapter lists the hardware setup procedures that you have to perform when installing system components.
Conventions used in this guide To make sure that you perform certain tasks properly, take note of the following symbols used throughout this manual. DANGER/WARNING: Information to prevent injury to yourself when trying to complete a task. CAUTION: Information to prevent damage to the components when trying to complete a task. IMPORTANT: Instructions that you MUST follow to complete a task. NOTE: Tips and additional information to help you complete a task.
Z9PE-D16 specifications summary Model Name Processor Support / System Bus Z9PE-D16 2 x Socket LGA 2011 ® ® Intel Xeon processor E5-2600 product family QPI 6.4/7.2/8.0 GT/s Intel® C602-A Core Logic EEB, 12” x 13” Form Factor ASUS Features Fan Speed Control V Rack Ready (Rack V and Pedestal dual use) V ASWM Enterprise 16 (4 Channels per CPU, 8DIMM per CPU) Memory Total Slots 1.5V/ 1.
Z9PE-D16 specifications summary Networking Graphic LAN 1 x Quad Port Intel® Ethernet Controller i350-AM4 GbE LAN Onboard I/O Connectors TPM Header PSU Connector 1 24-pin SSI power connector + 2*8-pin SSI 12V power connector Onboard socket for management card VGA Management Connector USB Connectors Rear I/O Connectors Monitoring Environment Fan Header Chassis Intruder Serial Port Header External USB Port VGA Port RJ-45 PS/2 KB/Mouse CPU Temperature FAN RPM ASPEED® AST2300 + 16MB VRAM 3 x USB pin
This chapter describes the motherboard features and the new technologies it supports.
Chapter summary 1 1.1 Welcome!....................................................................................... 1-3 1.3 Serial number label....................................................................... 1-4 1.2 1.4 Package contents.......................................................................... 1-3 Special features.............................................................................
1.1 Welcome! Thank you for buying an ASUS® Z9PE-D16 motherboard! The motherboard delivers a host of new features and latest technologies, making it another standout in the long line of ASUS quality motherboards! Before you start installing the motherboard, and hardware devices on it, check the items in your package with the list below. 1.2 Package contents Check your motherboard package for the following items.
Upgrade Kit table for Intel SCU Protocol Enabled ASRK #1 ASRK #2 ASRK #5 SATA/SAS (3Gb/s) ASRK #6 ASRK #9 1.3 SATA (3Gb/s) Ports Intel RSTe SAS RAID 5 4 ports No 4 ports Yes 8 ports No 8 ports Yes 8 ports SATA RAID 5 Serial number label Before requesting support from the ASUS Technical Support team, you must take note of the motherboard's serial number containing 12 characters xxS2xxxxxxxx shown as the figure below.
Intel® Hyper Threading The thread-level parallelism on each processor makes more efficient use of the processor resources, higher processing throughout and improved performance on today's multi-threaded software. Intel® EM64T The motherboard supports Intel® processors with the Intel® EM64T (Extended Memory 64 Technology). The Intel® EM64T feature allows your computer to run on 64-bit operating systems and access larger amounts of system memory for faster and more efficient computing.
Serial ATA III technology The motherboard supports the Serial ATA III technology through the Serial ATA interface and Intel® C600 chipset, delivering up to 6Gb/s data transfer rates. Additionally, get enhanced scalability, faster data retrieval, double the bandwidth of current bus systems. USB 2.0 technology The motherboard implements the Universal Serial Bus (USB) 2.0 specification, dramatically increasing the connection speed from the 12 Mbps bandwidth on USB 1.1 to a fast 480 Mbps on USB 2.0. USB 2.
This chapter lists the hardware setup procedures that you have to perform when installing system components. It includes description of the jumpers and connectors on the motherboard.
Chapter summary 2 2.1 Before you proceed...................................................................... 2-3 2.3 Central Processing Unit (CPU).................................................... 2-8 2.2 2.4 2.5 2.6 2.7 Motherboard overview.................................................................. 2-4 System memory.......................................................................... 2-13 Expansion slots...........................................................................
2.1 Before you proceed Take note of the following precautions before you install motherboard components or change any motherboard settings. • Unplug the power cord from the wall socket before touching any component. • Use a grounded wrist strap or touch a safely grounded object or a metal object, such as the power supply case, before handling components to avoid damaging them due to static electricity. • Hold components by the edges to avoid touching the ICs on them.
2.2 Motherboard overview Before you install the motherboard, study the configuration of your chassis to ensure that the motherboard fits into it. To optimize the motherboard features, we highly recommend that you install it in an ATX 1.1 compliant chassis. Ensure to unplug the chassis power cord before installing or removing the motherboard. Failure to do so can cause you physical injury and damage motherboard components! 2.2.
ASUS Z9PE-D16 2-5 BMC_LED ERR_DIMMC1 ERR_DIMMC2 ERR_DIMME1 ERR_DIMMD1 ERR_DIMME2 ERR_DIMMD2 ERR_DIMMF1 ERR_DIMMF2 ERR_CPU1 ERR_CPU2 ERR_DIMMB2 ERR_DIMMB1 ERR_DIMMH2 ERR_DIMMA2 ERR_DIMMH1 ERR_DIMMA1 ERR_DIMMG2 ERR_DIMMG1 Z9PE-D16 2.2.
2.2.4 Layout contents Slots/Soocket Page 1. CPU sockets 2-8 2. DDR3 sockets 2-13 3. PCI Express x8 / PCI Express x16 slots 2-16 Jumpers 2-6 Page 1. Clear RTC RAM (CLRTC1) 2-22 2. VGA controller setting (3-pin VGA_SW1) 2-23 3. LAN controller setting (3-pin LAN_SW1) 2-23 4. LSI MegaRAID or Intel RSTe selection jumper (3-pin RAID_SEL1) 2-24 5. ME firmware force recovery setting (3-pin ME_RCVR1) 2-24 6. DDR3 thermal event setting (3-pin DIMMTRIP1) 2-25 7. PMBus 1.
Internal connectors Page 1. ISAS connectors (7-pin ISAS1–4 [Gray]; 7-pin ISAS5–8 [Black]) 2-27 2. Hard disk activity LED connector (4-pin HDLED1) 3. PSAS connectors (7-pin PSAS1–8 [Light Blue]) 2-28 4. USB connectors (10-1 pin USB34, USB56; A-Type USB10) 5. CPU, front and rear fan connectors (4-pin CPU_FAN1-2, FRNT_FAN1–4, REAR_FAN1-2) 2-28 2-29 2-29 6. Serial General Purpose Input/Output connectors (8-1 pin PSGPIO 1/2, ISGPIO1/2, SGPIO1) 2-30 7.
2.3 Central Processing Unit (CPU) The motherboard comes with a surface mount LGA2011 socket designed for the Intel® Xeon E5-2600 family processor. 2.3.1 • Upon purchase of the motherboard, ensure that the PnP cap is on the socket and the socket contacts are not bent. Contact your retailer immediately if the PnP cap is missing, or if you see any damage to the PnP cap/socket contacts/motherboard components. ASUS will shoulder the cost of repair only if the damage is shipment/transit-related.
2. Press the left load lever with your thumb (A), then move it to the left (B) until it is released from the retention tab. To prevent damage to the socket pins, do not remove the PnP cap unless you are installing a CPU. 3. Slightly lift the load lever in the direction of the arrow. 4. Press the right load lever with your thumb (C), then move it to the right (D) until it is released from the retention tab. Lift the load lever in the direction of the arrow (E).
5. Push the left load lever (F) to lift the load plate (G). F G 6. Position the CPU over the socket, ensuring that the triangle mark is on the top‑right corner of the socket. Triangle mark The CPU fits in only one correct orientation. DO NOT force the CPU into the socket to prevent bending the connectors on the socket and damaging the CPU! 7. Remove the PnP cap (H) from the CPU socket and close the load plate (I).
8. Push down the right load lever (J), ensuring that the edge of the load plate is fixed by the lever (K). K J 9. Insert the right load lever under the retention tab. 10. Push down the left load lever (L), and then insert the lever under the retention tab (M).
11. Apply some Thermal Interface Material to the exposed area of the CPU that the heatsink will be in contact with, ensuring that it is spread in an even thin layer. Some heatsinks come with preapplied thermal paste. If so, skip this step. The Thermal Interface Material is toxic and inedible. DO NOT eat it. If it gets into your eyes or touches your skin, wash it off immediately, and seek professional medical help. 12.
2.4 System memory 2.4.1 Overview The motherboard comes with eight (per CPU) Double Data Rate 3 (DDR3) Dual Inline Memory Modules (DIMM) sockets. A DDR3 module has the same physical dimensions as a DDR2 DIMM but is notched differently to prevent installation on a DDR2 DIMM socket. DDR3 modules are developed for better performance with less power consumption. The figure illustrates the location of the DDR3 DIMM sockets: 2.4.
2 CPU Configuration DIMM_A2 DIMM_A1 DIMM_B2 DIMM_B1 DIMM_C2 DIMM_C1 DIMM_D2 DIMM_D1 X 1 DIMMs X 2 DIMMs X X 4 DIMMs X X X X 8 DIMMs X X X X X X 12 DIMMs X X X X X X X X 16 DIMMs 2 CPU Configuration DIMM_E2 DIMM_E1 DIMM_F2 DIMM_F1 DIMM_G2 DIMM_G1 DIMM_H2 DIMM_H1 1 DIMMs X 2 DIMMs X X 4 DIMMs X X X X 8 DIMMs X X X X X X 12 DIMMs X X X X X X X X 16 DIMMs 2-14 Chapter 2: Hardware information
2.4.3 1. 2. Installing a DIMM on a single clip DIMM socket Unlock a DIMM socket by pressing the retaining clip outward. DIMM notch Align a DIMM on the socket such that the notch on the DIMM matches the DIMM slot key on the socket. 1 2 DIMM slot key Unlocked retaining clip A DIMM is keyed with a notch so that it fits in only one direction. DO NOT force a DIMM into a socket in the wrong direction to avoid damaging the DIMM. 3.
2.5 Expansion slots In the future, you may need to install expansion cards. The following subsections describe the slots and the expansion cards that they support. Ensure to unplug the power cord before adding or removing expansion cards. Failure to do so may cause you physical injury and damage motherboard components. 2.5.1 Installing an expansion card To install an expansion card: 1. 2. 3. 4. 5. 6.
2.5.
PIKE slot (from CPU 1) PCIE 6 (x8 Gen3 link, Balck, from CPU 2) PCIE 5 (x16 Gen3 link, Balck, from CPU 2) PCIE 4 (x16 Gen3 link, White, from CPU 1) PCIE 3 (x16 Gen3 link, Balck, from CPU 2) PCIE 2 (x16 Gen3 link, Auto switch to x8 link if PCIE 1 is occupied, White, from CPU 1) PCIE 1 (x8 link, Gen3 link, MIO supported, White, from CPU 1) 2-18 Chapter 2: Hardware information
2.5.7 Connecting the ASRK Module (Optional) Follow the steps below to connect the ASRK Module to the connector on your motherboard. 1. Locate the ASRK connector on the motherboard. 2. Connect the ASRK module to the connector. For detail of Intel® Rapid Storage Technology enterprise utility, please refer to Chapter 5 RAID Configuration. Changing the module for different RAID settings: 1. Power off the system ,unplug AC cable and disengage the original module. 2.
2.5.8 Installing an ASUS PIKE RAID card Follow the steps below to install an optional ASUS PIKE RAID card on your motherboard. 2-20 1. Locate the PIKE RAID card slot on the motherboard. 2. Align the golden fingers of the PIKE RAID card with the PIKE RAID card slot. 3. Insert the PIKE RAID card into the PIKE RAID card slot. Ensure that it is completely seated on the PIKE RAID card slot.
2.5.9 Installing ASMB6 management board Follow the steps below to install an optional ASMB6 management board on your motherboard. 1. Locate the ASMB6 header on the motherboard. 2. Orient and press the ASMB6 management card in place.
2.6 1. Jumpers Clear RTC RAM (CLRTC1) This jumper allows you to clear the Real Time Clock (RTC) RAM in CMOS. You can clear the CMOS memory of date, time, and system setup parameters by erasing the CMOS RTC RAM data. The onboard button cell battery powers the RAM data in CMOS, which include system setup information such as system passwords. To erase the RTC RAM: 1. 2. 3. 4. Turn OFF the computer and unplug the power cord. Move the jumper cap from pins 1–2 (default) to pins 2–3.
2. 3. VGA controller setting (3-pin VGA_SW1) This jumper allows you to enable or disable the onboard VGA controller. Set to pins 1–2 to activate the VGA feature. LAN controller setting (3-pin LAN_SW1) These jumpers allow you to enable or disable the onboard Intel® I350 Quad Ports Gigabit LAN controllers. Set to pins 1-2 to activate the Gigabit LAN feature.
4. 5. LSI MegaRAID or Intel RSTe selection jumper (3-pin RAID_SEL1) This jumper allows you to select the PCH SATA RAID mode to use LSI MegaRAID software or Intel® Rapid Storage Technology enterprise 3.0 RAID. Place the jumper caps over pins 1–2 if you want to use the LSI MegaRAID software RAID Utility (default); otherwise, place the jumper caps to pins 2–3 to use the Intel® Rapid Storage Technology Enterprise Option ROM Utility.
6. DDR3 thermal event setting (3-pin DIMMTRIP1) 7. PMBus 1.2 PSU select jumper (3-pin SMART_PSU1) This jumper allows you to enable/disable DDR3 DIMM thermal sensing event pin. This jumper allows you to select PSU PMBus version, Set to pins 1-2 for PMBus, set to pins 2-3 for Others. PMBus 1.2 (Default) Others PMBus 1.
2.7 Connectors 2.7.1 Rear panel connectors 1 2 3 7 1. 2. 3. 4. 5. 6. 7. 8. 9. 8 4 5 6 9 PS/2 mouse port (green). This port is for a PS/2 mouse. DM_LAN 1 (RJ-45) port. This port allows Gigabit connection to a Local Area Network (LAN) through a network hub for dedicated BMC Mamagement function. Refer to the table below for the DM_LAN1 and LAN port LED indications. LAN 1 (RJ-45) port. This port allows Gigabit connection to a Local Area Network (LAN) through a network hub.
LAN port LED indications Activity/Link LED Speed LED OFF OFF Status Description Green Linked No link Blinking 2.7.2 1.
Hard disk activity LED connector (4-pin HDLED1) This LED connector is for the storage add-on card cable connected to the SATA or SAS add-on card. The read or write activities of any device connected to the SATA or SAS add-on card causes the front panel LED to light up. NC ADD_IN_CARDADD_IN_CARDNC 2. HDLED1 3.
4. 5. USB connectors (10-1 pin USB34, USB56; A-Type USB10) These connectors are for USB 2.0 ports. Connect the USB module cables to connectors USB34 and USB56, then install the modules to a slot opening at the back of the system chassis. These USB connectors comply with USB 2.0 specification that supports up to 480 Mbps connection speed. CPU, front and rear fan connectors (4-pin CPU_FAN1-2, FRNT_FAN1–4, REAR_FAN1-2) The fan connectors support cooling fans.
6. Serial General Purpose Input/Output connectors (8-1 pin PSGPIO 1/2, ISGPIO 1/2, SGPIO1) The SGPIO 1 connectors are used for the Intel Rapid Storage Technology Enterprise SGPIO interface that controls the LED pattern generation, device information and general purpose data. The PSGPIO 1/2 connectors are used for PIKE card. The ISGPIO 1/2 connectors are used for ASRK module. 7. 2-30 Serial port connectors (10-1 pin COM1/COM2) These connectors are for the serial (COM) ports.
8. TPM connector (20-1 pin TPM) This connector supports a Trusted Platform Module (TPM) system, which can securely store keys, digital certificates, passwords, and data. A TPM system also helps enhance network security, protects digital identities, and ensures platform integrity.
9. EATX power connectors (24-pin EATXPWR1, 8-pin EATX12V1/EATX12V2, PSUSMB1) These connectors are for an EATX power supply plugs. The power supply plugs are designed to fit these connectors in only one orientation. Find the proper orientation and push down firmly until the connectors completely fit. DO NOT forget to connect the 24+8+8-pin power plugs; otherwise, the system will not boot up.
10. System panel connector (20-1 pin PANEL1) This connector supports several chassis-mounted functions. (1) System power LED (3-pin PLED) This 3-pin connector is for the system power LED. Connect the chassis power LED cable to this connector. The system power LED lights up when you turn on the system power, and blinks when the system is in sleep mode. (2) System warning speaker (4-pin SPEAKER) This 4-pin connector is for the chassis-mounted system warning speaker.
11. Auxiliary panel connector (20-2 pin AUX_PANEL1) This connector is for additional front panel features including front panel SMB, locator LED and switch, chassis intrusion, and LAN LEDs. 2 2 GND I2C8SDA +5V AUX_LAN1LINK_ACT# AUX_LAN3LINK_# AUX_LAN2LINK_# AUX_LAN4LINK_ACT# NC I2C8SCL 1 +5VSB AUX_CHASSIS# GND AUX_LOCLED1 AUX_BMCLOCLED# AUX_BMCLOCBNT# GND AUX_BMCLOCLED# AUX_LOCLED2 PIN 1 3 4 5 4 (1) Front panel SMB (6-1 pin FPSMB) These leads connect the front panel SMBus cable.
This chapter describes the power up sequence, and ways of shutting down the system.
Chapter summary 3.1 3.2 3 Starting up for the first time......................................................... 3-3 Powering off the computer...........................................................
3.1 Starting up for the first time 1. After making all the connections, replace the system case cover. 2. Be sure that all switches are off. 3. Connect the power cord to the power connector at the back of the system chassis. 4. Connect the power to a power outlet that is equipped with a surge protector. 5. Turn on the devices in the following order: a. Monitor c. System power b. 6.
3.2 Powering off the computer 3.2.1 Using the OS shut down function If you are using Windows® 2008 Server: 1. Click the Start button, move the cursor to the triangle on the right of Log off, and then click Shut Down. 2. From the Shutdown Event Tracker, select the option that best describes why you want to shut down the computer. 3. Ensure that the Planned check box is checked. 4. If necessary, key in comments. 5. Click OK. 3.2.
This chapter tells how to change the system settings through the BIOS Setup menus. Detailed descriptions of the BIOS parameters are also provided.
Chapter summary 4 4.1 Managing and updating your BIOS............................................. 4-3 4.3 Main menu................................................................................... 4-10 4.2 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 BIOS setup program..................................................................... 4-7 Advanced menu.......................................................................... 4-11 Server Mgmt menu...........................................................
4.1 Managing and updating your BIOS The following utilities allow you to manage and update the motherboard Basic Input/Output System (BIOS) setup: 1. 2. 3. ASUS CrashFree BIOS 3 (To recover the BIOS using a bootable USB flash disk drive when the BIOS file fails or gets corrupted.) ASUS EZ Flash 2 (Updates the BIOS using a USB flash disk.) BUPDATER utility (Updates the BIOS in DOS mode using a bootable USB flash disk drive.) Refer to the corresponding sections for details on these utilities.
4.1.2 ASUS EZ Flash 2 Utility The ASUS EZ Flash 2 Utility feature allows you to update the BIOS without having to use a DOS‑based utility. Before you start using this utility, download the latest BIOS from the ASUS website at www.asus.com. To update the BIOS using EZ Flash 2 Utility 1. 2. Insert the USB flash disk that contains the latest BIOS file to the USB port. Enter the BIOS setup program. Go to the Tool menu to select ASUS EZ Flash 2 Utility and press to enable it.
• This function can support devices such as a USB flash disk with FAT 32/16 format and single partition only. • DO NOT shut down or reset the system while updating the BIOS to prevent system boot failure! Ensure to load the BIOS default settings to ensure system compatibility and stability. Press and select Yes to load the BIOS default settings. 4.1.3 BUPDATER utility The succeeding BIOS screens are for reference only. The actual BIOS screen displays may not be the same as shown.
The utility verifies the file, then starts updating the BIOS file. ASUSTek BIOS Update for DOS V1.06 (09/08/04) FLASH TYPE: MXIC 25L1605A Current ROM BOARD: Z9PE-D16 VER: 0203 DATE: 08/24/2011 Update ROM BOARD: Z9PE-D16 VER: 0206 DATE: 09/30/2011 PATH: WARNING! Do not turn off power during flash BIOS Note Writing BIOS: DO NOT shut down or reset the system while updating the BIOS to prevent system boot failure! 5. The utility returns to the DOS prompt after the BIOS update process is completed.
4.2 BIOS setup program This motherboard supports a programmable firmware chip that you can update using the provided utility described in section 4.1 Managing and updating your BIOS. Use the BIOS Setup program when you are installing a motherboard, reconfiguring your system, or prompted to “Run Setup.” This section explains how to configure your system using this utility. Even if you are not prompted to use the Setup program, you can change the configuration of your computer in the future.
4.2.1 BIOS menu screen Menu items Main Menu bar Configuration fields General help Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced Server Mgmt Event Logs Boot Monitor Security Tool Exit BIOS Information BIOS Vendor Core Version Compliancy BIOS Version Build Date American Megatrends 4.6.4.1 UEFI 2.1; PI 0.
4.2.3 Menu items The highlighted item on the menu bar displays the specific items for that menu. For example, selecting Main shows the Main menu items. The other items (Event Logs, Advanced, Monitor, Boot, Tool, and Exit) on the menu bar have their respective menu items. 4.2.4 Submenu items A solid triangle before each item on any menu screen means that the item has a submenu. To display the submenu, select the item and press . 4.2.
4.3 Main menu When you enter the BIOS Setup program, the Main menu screen appears. The Main menu provides you an overview of the basic system information, and allows you to set the system date, time settings. Main Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced Server Mgmt Event Logs Boot Monitor Security Tool Exit BIOS Information BIOS Vendor Core Version Compliancy BIOS Version Build Date American Megatrends 4.6.4.1 UEFI 2.1; PI 0.
4.4 Advanced menu The Advanced menu items allow you to change the settings for the CPU and other system devices. Take caution when changing the settings of the Advanced menu items. Incorrect field values can cause the system to malfunction. Main Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc.
Socket 1 CPU Information Enter to view socket soecific CPU Information. Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced Enter to view socket soecific CPU Information. Socket 1 CPU Information Genuine Intel(R) CPU @ 2.
DCU Streamer Prefetcher [Enabled] This Item allows you to enabled/disabled L1 data prefetcher. Configuration options: [Disabled] [Enabled] DCU IP Prefetcher [Enabled] This Item allows you to enabled/disabled L1 data prefetcher. Configuration options: [Disabled] [Enabled] Intel Virtualization Technology [Enabled] When enabled this item, a VMM can utilize the additional hardware capabilities provided by Vanderpool Technology. Configuration options: [Disabled] [Enabled] 4.4.
CPU C3 Report [Disabled] This item allows you to enabled/disabled CPU C3(ACPI C2) report. Configuration options: [Disabled] [Enabled] CPU C6 Report [Enabled] This item allows you to enabled/disabled CPU C6(ACPI C3) report. Configuration options: [Disabled] [Enabled] CPU C7 Report [Disabled] This item allows you to enabled/disabled CPU C7(ACPI C3) report. Configuration options: [Disabled] [Enabled] Package C State limit [C6] This item allows you to set package C State limit.
4.4.3 Chipset Configuration Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced QPI Configuration Memory Configuration CPU II0 Bridge Configuration PCH Configuration Intel(R) VT for Directed I/O Configuration QPI Configuration Page QPI Configuration Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc.
Memory Configuration Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc.
Patrol Scrub [Disabled] Allows to Enable/Disable Patrol Scrub. Configuration options: [Disabled] [Enabled] Demand Scrub [Enabled] Allows to Enabled/Disabled demand scrubing feature. Configuration options: [Enabled] [Disabled] Data Scrambling [Enabled] Allows to Enabled/Disabled data scrambling. Configuration options: [Enabled] [Disabled] Device Tagging [Disabled] Allows to Enabled/Disabled device tagging.
DIMM Information Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced CPU1 DIMM Information Node 0 Ch0 Dimm A1 Not Present Node 0 Ch0 Dimm A2 Not Present Node 0 Ch1 Dimm B1 Not Present Node 0 Ch1 Dimm B2 Present 2048 MB(DDR3) Node 0 Ch2 Dimm C1 Not Present Node 0 Ch2 Dimm C2 Not Present Node 0 Ch3 Dimm D1 Not Present Node 0 Ch3 Dimm D2 Not Present CPU2 DIMM Information CPU IIO Bridge Configuration Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc.
PCH Configuration Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced Name Stepping SB Chipset Configuration PCH Compatibility RID Deep Sx Onboard SATA RAID Oprom Audio Configuration Azalia HD Audio Support for PCH Compatibility Patsburg 05 (C0 Stepping) Revision ID(CRID) functionality.
Intel(R) VT for Directed I/O Configuration Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced Intel(R) VT-d [Enabled] Enables or Disables BIOS ACPI Auto Configuration. Intel(R) VT-d [Disabled] Allows you to enable or disable Intel VT-d. Configuration options: [Enabled] [Disabled] The following item appears only when you set Intel(R) VT-d to [Enabled]. Interrupt Remapping [Enabled] Allows to enable/disable VT-d Engine Interrupt Remapping support.
4.4.4 PCH SATA Configuration Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced SATA SATA SATA SATA SATA SATA Port1 Port2 Port3 Port4 Port5 Port6 Not Present ASUS DWR ATAPI WDC WD800JD(80.0GB) Not Present Not Present Not Present SATA Mode Serial-ATA Controller 0 Serial-ATA Controller 1 S.M.A.R.T. Status Check (1)IDE Mode. (2)AHCI Mode. (3)RAID Mode. [IDE Mode] [Enhanced] [Enhanced] [Enabled] →←: Select Screen ↑↓: Select Item Enter: Select Item +/-: Change Opt.
S.M.A.R.T. Status Check [Enabled] S.M.A.R.T. (Self-Monitoring, Analysis and Reporting Technology) is a monitor system. When read/write of your hard disk errors occur, this feature allows the hard disk to report warning messages during the POST. Configuration options: [Enabled] [Disabled] 4.4.5 PCH SCU SAS Configuration The PCH SCU SAS configuration items appears only when you installed the ASRK Module (optional) on the motherboard. This menu automatically detects and displays the Device 1-8.
4.4.6 PCI Subsystem Settings Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced PCI Bus Driver Version V 2.05.00 PCI Option ROM Handling PCI ROM Priority [EFI Compatible ROM] In case of multiple Option ROMs (Legacy and EFI Compatible), specifies what PCI option ROM to lanuch.
PCI Express Settings Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced PCI Express Link Register Settings ASPM Support [Disabled] WARNING: Enabling ASPM may cause some PCI-E device to fail Extended Synch Enables or DisablesPCI Express Device Relaxed Ordering. [Disabled] →←: Select Screen ↑↓: Select Item Enter: Select Item +/-: Change Opt. F1: General Help F2: Previous Values F5: Optimized Defaults F10: Save & Exit ESC: Exit Version 2.14.1219.
PCIE Slot Option Rom Configuration Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced Legacy 0pROM Support Launch Storage 0pROM [Enabled] PCIE1 Option Rom PCIE2 Option Rom PCIE3 Option Rom PCIE4 Option Rom PCIE5 Option Rom PCIE6 Option Rom PIKE Option Rom [Enabled] [Enabled] [Enabled] [Enabled] [Enabled] [Enabled] [Enabled] Enables or disables boot option for legacy mass storage device with option ROM.
4.4.7 Onboard LAN Configuration Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced Intel LAN Enable/Disable.
Intel LAN4 Enable [Enabled] Enables or disables Intel LAN4 function. Configuration options: [Disabled] [Enabled] LAN4 Option ROM Support [Enabled] Configuration options: [Disabled] [Enabled] 4.4.8 Intel TXT(LT-SX) Configuration Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc.
EHCI Hand-off [Disabled] This is a workaround for 0ses without EHCI ownership change should be claimed by EHCI driver. Configuration options: [Disabled] [Enabled] USB Hardware Delays and Time-outs USB transfer time-out [20 sec] The time-out value for control, bulk, and interrupt transfer. Configuration options: [1 sec] [5 sec] [10 sec] [20 sec] USB reset time-out [20 sec] USB mass storage device start unit command time-out.
USB Ports Configuration Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced EHCI Controller 1 EHCI Controller 2 [Enabled] [Enabled] Rear USB #1 Rear USB #2 Onboard USB #3 Onboard USB #4 Onboard USB #5 Onboard USB #6 Onboard USB #10 [Enabled] [Enabled] [Enabled] [Enabled] [Enabled] [Enabled] [Enabled] Enable/Disable USB 2.0 (EHCI) Support. →←: Select Screen ↑↓: Select Item Enter: Select Item +/-: Change Opt.
4.4.11 ACPI Settings Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced ACPI Settings Enable ACPI Auto Configuration [Disabled] Enables or Disables BIOS ACPI Auto Configuration. Enabled Hibernation [Enabled] ACPI Sleep State [S1 (CPU Stop Clock)] Lock Legacy Resources [Disabled] Enable ACPI Auto Configuration [Disabled] Allows you to enable or disable BIOS ACPI Auto Configuration.
4.4.12 WHEA Configuration Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced WHEA Support [Enabled] Enable or disable Windows Hardware Error Architecture. WHEA Support [Enabled] Allows you to enable or disable the Windows Hardware Error Architecture support. Configuration options: [Disabled] [Enabled] 4.4.13 APM setting Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc.
4.4.14 Serial Port Console Redirection Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced COM1 Console Redirection Console Redirection Settings [Disabled] COM2 Console Redirection Console Redirection Settings [Enabled] Serial Port for Out-of-Band Management/ Windows Emergency Management Services (EMS) Console Redirection [Disabled] Console Redirection Settings Consloe Redirection Enable or Disable.
Data Bits [8] Configuration options: [7] [8] Parity [None] A parity bit can be sent with the data bits to detect some transmission errors. [Mark] and [Space] parity do not allow for error detection. [Even] parity bit is 0 if the num of 1’s in the data bits is even [Odd] parity bit is 0 if num of 1’s in the data bits is odd [Mark] parity bit is always 1 [Space] parity bit is always 0 Stop Bits [1] Stop bits indicate the end of a serial data packet. (A start bit indicates the beginning.
Serial Port for Out-of-Band Management/ Windows Emergency Management Services (EMS) Console Redirection [Disabled] Enables or disables the console redirection feature. Configuration options: [Disabled] [Enabled] The following item appears only when you set Cinsloe Redirection to [Enabled]. Console Redirection Settings Out-of-Band Mgmt Port [COM1] Microsoft Windows Emergency Management Services (EMS) allow for remote management of a Windows Server OS through a serial port.
4.4.15 ME Subsystem Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced ME Subsystem Help. Intel ME Subsystem Configuration ME BIOS Interface Version 1.2 ME Version 2.1.5.
Serial Port [Enabled] Allows to enables or disables the serial port. Configuration options: [Disabled] [Enabled] Device Mode [Standard Serial Port Mode] Allows to change the serial port mode. Configuration options: [Standard Serial Port Mode] 4.4.17 Runtime Error Logging Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc.
4.5 Server Mgmt menu The Server Mgmt menu displays the server mgmt status, and allows you to change the settings. The Server Mgmt menu appears only when you install ASMB card on the motherboard. Main Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced Server Mgmt Event Logs Boot Monitor Security Tool Exit BMC Firmware: x.
4.5.1 System Event Log Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Server Mgmt Enabling/Disabling Options SEL Components [Disabled] Erasing Settings Erase SEL When SEL is Full [No] [Do Nothing] Custom EFI Logging Options Note: All values changed here do not take effect until computer is restarted. Change this to enable or disable all features of system Event Logging during boot. →←: Select Screen ↑↓: Select Item Enter: Select Item +/-: Change Opt.
4.5.2 BMC network configuration Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Server Mgmt BMC network configuration DM_KAN1 DM_LAN1 IP Address in BMC: DM_LAN1 Subnet Mask in BMC: DM_LAN1 Gateway Address in BMC : DM_LAN1 MAC Address in BMC: DM_LAN1 Address Source in BMC: Configuration Address source 192.168.001.001 255.255.255.000 000.000.000.000 00.CE.01.87.72.
4.6 Event Logs menu The Event Logs allows you to change or view the event log settings. Main Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced Server Mgmt Event Logs Boot Monitor Security Tool Exit Press to change the Smbios Event Log configuration. Change Smbios Event Log Settings View Smbios Event Log View System Event Log →←: Select Screen ↑↓: Select Item Enter: Select Item +/-: Change Opt.
When Log is Full [Do Nothing] Allows to choose options for reactions to a full Smbios Event Log. Configuration options: [Do Nothing] [Erase Immediately] Smbios Event Log Standard Settings Log System Boot Event [Disabled] Allows to choose options to enable/disable logging of System boot event. Configuration options: [Enabled] [Disabled] MECI [1] Mutiple Event Count Increment (MECI).
4.7 Boot menu The Boot menu items allow you to change the system boot options. Main Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced Server Mgmt Event Logs Boot Monitor Security Tool Exit Boot Configuration Setup Prompt Timeout Bootup NumLock State 1 [On] Full Screen Logo [Enabled] CSM16 Module Version GateA20 Active Option ROM Messages Interrupt 19 Capture Boot Device Seeking UEFI Boot 07.
Boot Device Seeking [Endless PXE] [Endless PXE] Continuous seek remote boot image until boot image found or user abort (press Ctrl+Alt+Del). [Normal] Seek remote boot image once then stop. UEFI Boot [Disabled] Enables or disables UEFI Boot. Configuration options: [Disabled] [Enabled] Boot Option Priorities These items specify the boot device priority sequence from the available devices. The number of device items that appears on the screen depends on the number of devices installed in the system.
4.8 Monitor menu The Monitor menu displays the system temperature/power status, and allows you to change the fan settings. Main Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc.
FAN Speed Control [Generic Mode] Allows you to configure the ASUS Smart Fan feature that smartly adjusts the fan speeds for more efficient system operation. Configuration options: [Generic Mode] [High Speed Mode] [Full Speed Mode] 4.9 Security menu The Security menu items allow you to change the system security settings. Main Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc.
To clear the administrator password, follow the same steps as in changing an administrator password, but press when prompted to create/confirm the password. After you clear the password, the Administrator Password item on top of the screen shows Not Installed. User Password If you have set a user password, you must enter the user password for accessing the system. The User Password item on top of the screen shows the default Not Installed. After you set a password, this item shows Installed.
4.11 Exit menu The Exit menu items allow you to save or discard your changes to the BIOS items. Main Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced Server Mgmt Event Logs Boot Monitor Security Tool Exit Discard Changes & Exit Save Changes & Reset Discard Changes & Reset Exit system setup without saving any changes. Restore Defaults Boot Override SATA P2: ASUS DRW-2014L1T AMI Virtual CDROM 1.00 SATA P3: WDC WD800JD-00LSA0 AMI Virtual Floppy0 1.
4-48 Chapter 4: BIOS setup
This chapter provides instructions for setting up, creating, and configuring RAID sets using the available utilities.
Chapter summary 5 5.1 Setting up RAID............................................................................. 5-3 5.3 Intel® Rapid Storage Technology enterprise SCU / SATA Option 5.2 5.4 LSI Software RAID Configuration Utility..................................... 5-5 ROM Utility................................................................................... 5-25 Intel® Rapid Storage Technology enterprise Utility(Windows)....
5.1 Setting up RAID The motherboard supports the following RAID solutions: • • LSI MegaRAID software RAID Configuration Utility with RAID 0, RAID 1, and RAID 10 support (for both Linux and Windows OS). Intel Rapid Storage Technology enterprise SCU / SATA Option ROM Utility with RAID 0, RAID 1, RAID 10, and RAID 5 support (for Windows OS only). 5.1.1 RAID definitions RAID 0 (Data striping) optimizes two identical hard disk drives to read and write data in parallel, interleaved stacks.
5.1.2 Installing hard disk drives The motherboard supports Serial ATA for RAID set configuration. For optimal performance, install identical drives of the same model and capacity when creating a disk array. To install the SATA hard disks for RAID configuration: 1. 2. 3. Install the SATA hard disks into the drive bays following the instructions in the system user guide. Connect a SATA signal cable to the signal connector at the back of each drive and to the SATA connector on the motherboard.
5.2 LSI Software RAID Configuration Utility The LSI MegaRAID software RAID configuration utility allows you to create RAID 0, RAID 1, or RAID 10 set(s) from SATA hard disk drives connected to the SATA connectors supported by the motherboard southbridge chip. To enter the LSI MegaRAID software RAID configuration utility: 1. 2. Turn on the system after installing all the SATA hard disk drives.
Menu Description Configure Allows you to create RAID 0, RAID 1 or RAID 10 set using the Easy Configuration or the New Configuration command.
2. The ARRAY SELECTION MENU displays the available drives connected to the SATA ports. Use the up/down arrow keys to select the drives you want to include in the RAID set, and then press . When selected, the drive indicator changes from READY to ONLIN A[X]-[Y], where X is the array number, and Y is the drive number. LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.
5. Press again, the virtual drive information appears including a Virtual Drive menu that allows you to change the virtual drive parameters. LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Virtual VersionDrive(s) A.10.09231523R Configured LD RAID Size #Stripes StripSzMENU Status Easy Configuration - ARRAY SELECTION Management 0 Menu 1 148.
8. 9. Select Units from the Virtual Drive sub-menu, and then press . Select the units for virtual drive size from the menu, and then press . LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Virtual VersionDrive(s) A.10.09231523R Configured LD RAID Size #Stripes StripSzMENU Status Easy Configuration - ARRAY SELECTION Management 0 Menu 1 148.
12. When finished setting the selected virtual drive configuration, select Accept from the menu, and then press . LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Virtual VersionDrive(s) A.10.09231523R Configured LD RAID Size #Stripes StripSzMENU Status Easy Configuration - ARRAY SELECTION Management 0 Menu 1 148.
Using New Configuration When a RAID set already exists, using the New Configuration command erases the existing RAID configuration data. If you do not want to delete the existing RAID set, use the View/Add Configuration command to view or create another RAID configuration. To create a RAID set using the New Configuration option 1. From the Management Menu, select Configure > New Configuration, and then press . LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.
5.2.2 Adding or viewing a RAID configuration You can add a new RAID configuration or view an existing configuration using the View/Add Configuration command. Adding a new RAID configuration To add a new RAID configuration: 1. From the Management Menu, select Configure > View/Add Configuration, and then press . LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.
5.2.3 Initializing the virtual drives After creating the RAID set(s), you must initialize the virtual drives. You may initialize the virtual drives of a RAID set(s) using the Initialize or Objects command on the Management Menu. Using the Initialize command To initialize the virtual drive using the Initialize command 1. From the Management Menu, select Initialize, and then press . LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.
3. Press to start initialization. When prompted, select Yes from the Initialize? dialog box, and then press . LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.09231523R Management Menu Configure Initialize Objects Rebuild Check Consistency LD RAID 0 1 Virtual Drive(s) Configured Size #Stripes StripSz 148.
Using the Objects command To initialize the virtual drives using the Objects command 1. From the Management Menu, select Objects > Virtual Drive, and then press . LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.09231523R Objects Management Menu Adapter Configure Virtual Drive Initialize Physical Drive Objects Rebuild Check Consistency Change VD Parameters Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option 2.
3. Select Initialize from the pop-up menu, and then press to start initialization. LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.09231523R Vitual Drive(1) Virtual Drive 0 Objects Management Menu Adapter Configure Virtual Drive Initialize Physical Drive Objects Vitual Drive(0) Rebuild Initialze Check Consistency Check Consistency View/Update Parameters Initilize VD Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option 4.
5.2.4 Rebuilding failed drives You can manually rebuild failed hard disk drives using the Rebuild command in the Management Menu. To rebuild a failed hard disk drive 1. From the Management Menu, select Rebuild, and then press . LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.09231523R Management Menu Configure Initialize Objects Rebuild Check Consistency Rebuild PD(s) Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option 2.
3. After selecting the drive to rebuild, press . When prompted, press to rebuild the drive. LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.09231523R REBUILD - PHYSICAL DRIVES SELECTION MENU Management Menu PORT # Configure 0 ONLIN A00-00 Initialize Objects 1 RBLD A00-01 Rebuild Check Consistency Rebuilding Of Drive Will Take A Few Minutes.
5.2.5 Checking the drives for data consistency You can check and verify the accuracy of data redundancy in the selected virtual drive. The utility can automatically detect and/or detect and correct any differences in data redundancy depending on the selected option in the Objects > Adapter menu. The Check Consistency command is available only for virtual drives included in a RAID 1 or RAID 10 set. Using the Check Consistency Command To check data consistency using the Check Consistency command 1.
3. When prompted, use the arrow keys to select Yes from the Consistency Check? dialog box, and then press . LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.
Using the Objects command To check data consistency using the Objects command 1. 2. 3. 4. 5. From the Management Menu, select Objects, and then select Virtual Drive from the sub-menu. Use the arrow keys to select the virtual drive you want to check, and then press . Select Check Consistency from the pop-up menu, and then press . When prompted, use the arrow keys to select Yes from the dialog box to check the drive. When checking is complete, press any key to continue.
5.2.6 Deleting a RAID configuration To delete a RAID configuration 1. From the Management Menu, select Configure > Clear Configuration, and then press . LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.
5.2.7 Selecting the boot drive from a RAID set You must have created a new RAID configuration before you can select the boot drive from a RAID set. See section 5.2.1 Creating a RAID set: Using New Configuration for details. To select the boot drive from a RAID set 1. From the Management Menu, select Configure > Select Boot Drive, and then press . LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.
5.2.8 Enabling WriteCache You may manually enable the RAID controller’s WriteCache option after creating a RAID set to improve the data transmission performance. When you enable WriteCache, you may lose data when a power interruption occurs while transmitting or exchanging data among the drives. The WriteCache function is recommended for RAID 1 and RAID 10 sets. To enable WriteCache 1. 2.
5.3 Intel® Rapid Storage Technology enterprise SCU/SATA Option ROM Utility The Intel® Rapid Storage Technology enterprise SCU / SATA Option ROM utility allows you to create RAID 0, RAID 1, RAID 10 (RAID 1+0), and RAID 5 set(s) from Serial ATA hard disk drives that are connected to the Serial ATA connectors supported by the Southbridge. You can create RAID mode by use of onboard AHCI SATA ports. Also, when installed optional ASRK module, you can use onboard scu SAS ports to create RAID mode.
To enter the Intel® Rapid Storage Technology enterprise SCU Option ROM utility: 1. Install all the Serial ATA/SAS hard disk drives. 3. During POST, press to display the utility main menu. 2. Turn on the system. Intel(R) Rapid Storage Technology enterprise - SATA Option ROM - 3.0.0.1104 Copyright(C) 2003-11 Intel Corporation. All Rights Reserved. [ MAIN MENU ] 1. Create RAID Volume 2. Delete RAID Volume 3. Reset Disks to Non-RAID 4.
5.3.1 Creating a RAID set To create a RAID set 1. From the utility main menu, select 1. Create RAID Volume and press . The following screen appears. Intel(R) Rapid Storage Technology enterprise - SATA Option ROM - 3.0.0.1104 Copyright(C) 2003-11 Intel Corporation. All Rights Reserved. [ CREATE VOLUME MENU ] Name: RAID Level: Disks: Strip Size: Capacity: Volume0 RAID0(Stripe) Select Disks 128KB 0.
6. Use the up/down arrow keys to select the stripe size for the RAID array (for RAID 0, 10 and 5 only), and then press . The available stripe size values range from 4 KB to 128 KB. The following are typical values: RAID 0: 128KB RAID 10: 64KB RAID 5: 64KB We recommend a lower stripe size for server systems, and a higher stripe size for multimedia computer systems used mainly for audio and video editing. 7. 8.
2. 3. 4. Enter a name for the recovery set and press . When the RAID Level item is selected, press the up/down arrow keys to select Recovery, and then press . When the Disks item is selected, press to select the hard disk drives you want to include in the recovery set. The SELECT DISKS screen appears. [ SELECT DISKS ] Port 0 1 2 3 Drive Model ST3300656SS ST3300656SS ST3300656SS ST3300656SS Serial # HWAS0000991753TR 37VN00009846RAJ1 397600009846UEDY GWC50000991756G6 Size 279.
5.3.3 Deleting a RAID set Take caution when deleting a RAID set. You will lose all data on the hard disk drives when you delete a RAID set. To delete a RAID set: 1. From the utility main menu, select 2. Delete RAID Volume and press . The following screen appears. Intel(R) Rapid Storage Technology enterprise - SATA Option ROM - 3.0.0.1104 Copyright(C) 2003-11 Intel Corporation. All Rights Reserved. [ DELETE VOLUME MENU ] Name Volume0 Level RAID0(Stripe) Drives 2 Capacity 298.
5.3.4 Resetting disks to Non-RAID Take caution before you reset a RAID volume hard disk drive to non-RAID. Resetting a RAID volume hard disk drive deletes all internal RAID structure on the drive. To reset a RAID set hard disk drive: 1. From the utility main menu, select 3. Reset Disks to Non-RAID and press . The following screen appears. [ RESET RAID DATA ] Resetting RAID disk will remove its RAID structures and revert it to a non-RAID disk.
5.3.5 Exiting the Intel® Rapid Storage Technology utility To exit the utility: 1. From the utility main menu, select 4. Exit, and then press . The following warning message appears. [ CONFIRM EXIT ] Are you sure you want to exit? (Y/N): 2. Press to exit or press to return to the utility main menu. 5.3.6 Rebuilding the RAID This option is only for the RAID 1 set.
3. The utility immediately starts rebuilding after the disk is selected. The status of the degraded RAID volume is changed to “Rebuild”. Intel(R) Rapid Storage Technology enterprise - SATA Option ROM - 3.0.0.1104 Copyright(C) 2003-11 Intel Corporation. All Rights Reserved. [ MAIN MENU ] 1. Create RAID Volume 2. Delete RAID Volume 3. Reset Disks to Non-RAID 4.
5.3.7 Setting the Boot array in the BIOS Setup Utility You can set the boot priority sequence in the BIOS for your RAID arrays when creating multi-RAID using the Intel® Rapid Storage Technology. To set the boot array in the BIOS: Set at least one of the arrays bootable to boot from the hard disk. 1. 2. 3. 4. 5. 5-34 Reboot the system and press to enter the BIOS setup utility during POST. Go to the Boot menu and select the boot option priority.
5.4 Intel® Rapid Storage Technology enterprise Utility (Windows) The Intel® Rapid Storage Technology enterprise utility allows you to create RAID 0, RAID 1, RAID 10 (RAID 1+0), and RAID 5 set(s) from Serial ATA hard disk drives that are connected to the Serial ATA connectors supported by the Southbridge. You need to manually install the Intel® Rapid Storage Technology enterprise utility on a Windows® operating system. Please refer to the installation instructions in Chapter 6.
5.4.1 Creating a RAID set To create a RAID set 1. From the utility main menu, select Create Volume and select volume type. 3. Enter a name for the RAID set, then select the array disks. 5. Then click Next. 2. 4. 5-36 Then click Next. Select Volume Size tab, you can drag the bar to decide the volume size. • If you hard disk with existing data and you don’t want to keep data from one of the selected disks, choose NO in next column (If displayed).
6. Confirm volume creation, than click Create Volume to continue. This process could take a while depending on the number and size of the disks. You can continue using other applications during this time. When display Volume Ceation Complete message, you can click OK to finish. You still need to partition your new volume using Windows Disk Management before adding any data.
5.4.2 Change Volume Type When you are finished to create a RAID set, you can view or change related items in the Volume Properties field. According to the following steps to change the type in Volume Properties: 1. Click the SAS / SATA array items you want to change in Volumes field. 3. You can change the Name, Select the new volume type, and Select additional disks to include in the new volume if needed. 2 4. From the Volume Properties field, select Type:RAID 1 Change type.
5.4.3 Delete volume Take caution when deleting a volume. You will lose all data on the hard disk drives.Back up data before continuing. To delete a volume: 1. From the utility main menu, select the volume (exp. Volume_0000) in Volumes field you want to delete. 2. Then select Delete volume in Volume Properties field. The following screen appears. 3. Click Yes to delete the volume and return to the utility main menu, or click No to return to the main menu.
5.4.4 Preferences System Preferences Allow you set to show the notification area icon and show system information, warning, or errors here.
This chapter provides the instructions for installing the necessary drivers for different system components.
Chapter summary 6 6.1 RAID driver installation................................................................ 6-3 6.3 Intel@ Network Connections Software installation.................. 6-17 6.2 6.4 6.5 6.6 6.7 Intel® chipset device software installation................................ 6-15 VGA driver installation............................................................... 6-20 Intel® C600 Series Chipset SAS RAID (SATA mode) Drivers... 6-23 Microsoft .NET Framework 3.5 SP1.........................
6.1 RAID driver installation After creating the RAID sets for your server system, you are now ready to install an operating system to the independent hard disk drive or bootable array. This part provides the instructions on how to install the RAID controller drivers during OS installation. 6.1.1 Creating a RAID driver disk The system does not include a floppy drive. You have to use a USB floppy drive when creating a SATA RAID driver disk.
LSI 2008 SAS2 Driver LSI 2008 SAS2 Driver Windows XP 32 bit Windows XP 64 bit Windows Server 2003 32 bit Windows Server 2003 64 bit Windows Vista 32 bit Windows Vista 64 bit Windows Server 2008 32 bit Windows Server 2008 64 bit Windows 7 32 bit Windows 7 64 bit Windows Server 2008 R2 64 bit RHEL 4 UP7 32 bit RHEL 4 UP7 64 bit RHEL 4 UP8 32 bit RHEL 4 UP8 64 bit Back Exit 6. 7. 8. 6-4 Locate the RAID driver and place a blank, high-density floppy disk to the floppy disk drive. Press .
To create a RAID driver disk in Windows® environment 1. Start Windows®. 3. Go to the Make disk menu, and then select the type of RAID driver disk you want to create. 2. 4. 5. Place the motherboard support DVD into the optical drive. Insert a floppy disk into the USB floppy disk drive. Follow succeeding screen instructions to complete the process. Write-protect the floppy disk to avoid computer virus infection. To create a RAID driver disk in Red Hat® Enterprise Linux server environment 1. 2.
6.1.2 Installing the RAID controller driver During Windows® Server 2008 OS installation To install the RAID controller driver when installing Windows® Server 2008 OS 1. 2. 3. 6-6 Boot the computer using the Windows® Server 2008 OS installation disc. Follow the screen instructions to start installing Windows Server 2008. When prompted to choose a type of installation, click Custom (advanced). Click Load Driver.
4. A message appears, reminding you to insert the installation media containing the driver of the RAID controller driver. If you have only one optical drive installed in your system, eject the Windows OS installation disc and replace with the motherboard Support DVD into the optical drive. Click Browse to continue. 5. Locate the driver in the corresponding folder of the Support DVD, and then click OK to continue. 6. Select the RAID controller driver you need from the list and click Next. 7.
Red Hat® Enterprise Linux OS 5.6 To install the LSI MegaRAID controller driver when installing Red Hat® Enterprise OS: 1. 2. Boot the system from the Red Hat® OS installation CD. At the boot:, type linux dd noprobe=ata1 noprobe=ata2..., then press . The number of ata varies with the hard disk drive number you have when building a RAID set.
5. When asked if you will load additional RAID controller drivers, select No, then press . More Driver Disks? Do you wish to load any more driver disks? Yes 6. No Follow the onscreen instructions to finish the OS installation. 7. When the installation is completed, DO NOT click Reboot. Press + + to switch to the command-line interface from graphic user interface. 8. Type the following commands when using a Legacy floppy.
Red Hat® Enterprise Linux OS 6.1 To install the LSI MegaRAID controller driver when installing Red Hat® Enterprise OS: 1. Boot the system from the Red Hat® OS installation CD. 3. At the boot:, type vnlinuz initrd=initrd.img xdriver=vesa nomodeset dd , then press . 3. Select Yes using the key when asked if you have the driver disk, then press . 2. Press to edit options.
4. You have multiple devices which could serve as source for a driver disk. Choose one you like to use and select OK, then press . Driver Disk Sou8rce You have multiple devices which could serve as source for a driver disk. Which would you like to use? sdc sdd sdb sr0 OK 5. Cancel Insert the Red Hat® Enterprise RAID driver disk to the USB floppy disk drive, select OK, then press . Insert Driver Disk Insert your driver disk into /dev/sdb and press “OK” to continue.
SUSE Linux 11 OS To install the LSI MegaRAID controller driver when installing SUSE Linux Enterprise Server OS: 1. 2. Boot the system from the SUSE OS installation CD. Use the arrow keys to select Installation from the Boot Options menu. Boot from Hard Disk Installation Repair Installed System Rescue System Check Installation Media Firmware Test Memory Test Boot Options | F1 Help F2 Language F3 Video Mode English(US) 1024 X768 3.
4. Insert the RAID driver disk to the floppy disk drive. Type the command acpi=off apic=bigsmp brokenmodules=ahci in Boot Options field, and press . Boot from Hard Disk Installation Repair Installed System Rescue System Check Installation Media Firmware Test Memory Test Boot Options acpi=off apic=bigsmp brokenmodules=ahci F1 Help F2 Language F3 Video Mode English(US) 1024 X768 5.
6. The drivers for the RAID controller are installed to the system as shown below. Please choose the Driver Update medium. sda: USB Floppy sr0: CD-ROM, ASUS DRW-1612BLT sdb: Disk, LSI MEGA RAID sd3: Disk, LSI MEGA RAID Console other device OK 7. 6-14 Back Select Back and follow the onscreen instructions to finish the installation.
6.2 Intel® chipset device software installation This section provides the instructions on how to install the Intel® chipset device software on the system. You need to manually install the Intel® chipset device software on a Windows operating system. To install the Intel® chipset device software: 1. 2. Restart the computer, and then log on with Administrator privileges. Insert the motherboard/system support DVD to the optical drive.
6-16 5. Select Yes to accept the terms of the License Agreement and continue the process. 6. Read the Readme File Information and press Next to continue the installation. 7. Toggle Yes, I want to restart the computer npw and click Finish to complete the setup process.
6.3 Intel@ Network Connections Software installation This section provides the instructions on how to install the Intel® Network Connections Software on the system. You need to manually install the Intel® Network Connections Software on a Windows® operating system. To install the Intel® Network Connections Software: 1. 2. Restart the computer, and then log on with Administrator privileges. Insert the motherboard/system support DVD to the optical drive.
6-18 5. Click Next when the Intel(R) Network Connections–InstallShield Wizard window appears. 6. Toggle I accept the terms in the license agreement and click Next to continue. 7. Click the Intel(R) PROSet for Windows Device Manager box, and then click Next to start the installation.
8. Follow the screen instructions to complete installation. 9. When finished, press Finish to continue.
6.4 VGA driver installation This section provides the instructions on how to install the ASPEED Video Graphics Adapter (VGA) driver. You need to manually install the ASPEED VGA driver on a Windows® operating system. To install the ASPEED VGA driver: 1. 2. Restart the computer, and then log on with Administrator privileges. Insert the motherboard/system support DVD to the optical drive. The support DVD automatically displays the Drivers menu if Autorun is enabled in your computer.
5. Toggle I accept the terms in the license agreement and click Next to continue. 6. Enter the user information and click Next to continue. 7. Select a setup type and click Next to continue.
6-22 8. Click Install to start driver installation. 9. When the installation completes, click Finish to restart your computer before using the program.
6.5 Intel® C600 Series Chipset SAS RAID (SATA mode) Drivers This section provides the instructions on how to install the Intel® C600 Series Chipset SAS RAID (SATA mode) Drivers on the system. You need to manually install the Intel® C600 Series Chipset SAS RAID (SATA mode) Drivers on a Windows operating system. To install the drivers: 1. 2. Restart the computer, and then log on with Administrator privileges. Insert the motherboard/system support DVD to the optical drive.
6.6 Microsoft .NET Framework 3.5 SP1 This section provides the instructions on how to install the Microsoft .NET Framework 3.5 SP1 software on the system. You need to manually install the Intel® Microsoft .NET Framework 3.5 SP1 software on a Windows operating system. To install the drivers: 1. 2. Restart the computer, and then log on with Administrator privileges. Insert the motherboard/system support DVD to the optical drive.
6.7 Intel® Rapid Storage Technology enterprise 3.0 installation This section provides the instructions on how to install the Intel® Rapid Storage Technology enterprise 3.0 on the system. You need to manually install the Intel® Rapid Storage Technology enterprise 3.0 utility on a Windows® operating system. To install the Intel® Rapid Storage Technology enterprise 3.0 utility: 1. 2. Restart the computer, and then log on with Administrator privileges.
6-26 5. Read the Warning message and click Next to continue. 6. Read the License Agreement and click Yes to continue. 7. Read the Readme File Information and click Next to continue.
8. After completing the installation, click Next to complete the setup process. 9. Select Yes, I want to restart my computer now and click Finish to restart your computer before using the program.
6.8 Intel® I350 Gigabit Adapters Driver installation This section provides the instructions on how to install Intel® I350 Gigabit Adapters Driver. To install the Intel® I350 Gigabit Adapters Driver on a Windows® OS: 1. 2. Restart the computer, and then log on with Administrator privileges. Insert the motherboard/system support DVD to the optical drive. The DVD automatically displays the Drivers menu if Autorun is enabled in your computer.
4. When the Intel® PRO Network Connections – InstallShield Wizard window appears, click Next to start the installation. 5. Click I accept the terms in the license agreement and then click Next to continue.
6-30 6. Select the programs you want to install and click Next to continue. 7. Click Install to start the installation.
8. The programs you select are being installed. 9. Click Finish to finish the installation.
6.9 Management applications and utilities installation The support DVD that came with the motherboard package contains the drivers, management applications, and utilities that you can install to avail all motherboard features. The contents of the support DVD are subject to change at any time without notice. Visit the ASUS website (www.asus.com) for updates. 6.9.1 Running the support DVD Place the support DVD to the optical drive.
6.9.3 Utilities menu The Utilities menu displays the software applications and utilities that the motherboard supports. Click an item to install. 6.9.4 Make disk menu The Make disk menu contains items to create the Intel RAID driver disks. 6.9.5 Contact information Click the Contact tab to display the ASUS contact information. You can also find this information on the inside front cover of this user guide.
6-34 Chapter 6: Driver installation
This appendix includes additional information that you may refer to when configuring the motherboard.
Appendix summary A.1 A Z9PE-D16 block diagram..............................................................
A.
A-4 Appendix A: Reference information
ASUS contact information ASUSTeK COMPUTER INC. (Taiwan) Address Telephone Fax E-mail Web site Technical Support Telephone Online Support 15 Li-Te Road, Peitou, Taipei, Taiwan 11259 +886-2-2894-3447 +886-2-2890-7798 info@asus.com.tw http://www.asus.com.tw +886-2-2894-3447 (0800-093-456) http://support.asus.com/techserv/techserv.aspx ASUSTeK COMPUTER INC. (China) Address Telephone Fax Web site Technical Support Telephone Online Support No.
(510)739-3777/(510)608-4555 800 Corporate Way, Fremont, CA 94539. Asus Computer International Date : Signature : Representative Person’s Name : Oct. 28, 2011 Steve Chang / President This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.