Specifications
Maintenance  3-3 
Maintenance Procedures 
 CAUTION!
Safety
  Maintenance procedures should only be performed by trained service 
technicians. Refer to the   section for more information. 
 WARNING!  Unless otherwise specified, the Cure Module should be shut down while 
performing maintenance or troubleshooting procedures. Refer to “System 
Shutdown” in the TC V3 Operations Manual. 
Conveyor Torque Limiter Adjustment 
To adjust the conveyor torque limiter: 
1.  Turn the power off by moving the Main Switch to the OFF position.  
2.  Remove the access cover at the output of the conveyor and set aside.  
NOTE  The torque limiter is mounted on the motor shaft, behind the motor ( ). 
Figure 3-1 Torque Limiter Adjustment
3.  Unscrew the latch-tightening screw with an Allen wrench ( ). 
4.  Adjust the limiter by turning the adjustment ring to allow space to turn the gear by hand. 
5.  Tighten the latch-tightening screw. 
6.  Turn the power back on by moving the Main Switch to the ON position.  
7.  Before starting a production, activate the conveyor movement. Make sure the gear on the 
motor shaft does not slip. 
8.  Replace the access cover. 
Allen Wrench 
Gear 
Torque Limiter 
Latch-tightening 
Screw 
Adjustment Ring 