Specifications
3-4  Maintenance 
Conveyor Incremental Encoder Adjustment 
The Conveyor Incremental Encoder returns an accurate measurement of conveyor speed to the PLC. In 
the TC oven, the encoder uses a close loop control to ensure the accuracy of the conveyor speed. 
Replace the encoder if it is damaged or the speed measurement is inaccurate. 
Various conveyor speeds can be used depending on the encoder installed. Table 3-2 lists the available 
encoder options. 
Table 3-2  Optional Encoders 
CONVEYOR SPEED  ENCODER PART NUMBER  DESIGNATION 
80-400  050865  Encoder 360 pulses 
160-800 (STANDARD)  050864  Encoder 200 pulses 
300-1500  049615  Encoder 100 pulses 
 CAUTION!
To replace the Conveyor Incremental Encoder: 
  For ovens built before May 2006, the speed measurement is controlled by an 
inductive sensor (VIT’s part number: 007546) 
1.  Remove the right hood in front of the machine, at the exit of the oven. 
2.  Fix the elastic couplings on the encoder and on the shaft. 
3.  Attach the encoder to the support bracket on the frame. 
4.  Plug the encoder jack into the female jack. 
5.  Turn the conveyor on and ensure that the encoder and shaft are properly aligned. 
6.  Verify the speed value on the control screen is correct. 
Figure 3-2 Conveyor Counter Cell Location 
7.  Check again to make sure the cell detects each tooth of the gear. 
8.  Recalibrate the close loop of the conveyor and check that the real speed of the conveyor is 
equal to the calculated speed by the PLC. 
9.  Replace the access cover. 
Support Bracket 
Shaft 
Encoder 
Elastic Coupling 