Thermocouple Replacement 
To replace a thermocouple: 
1.  Turn the power off by moving the Main Switch to the OFF position.  
2.  Open the top rear access cover. 
3.  Disconnect the defective thermocouple from the connector (Figure 3-12). 
4.  Unscrew the pressure screw. 
5.  Remove the old thermocouple. 
6.  Replace with the new thermocouple. 
7.  Tighten the pressure screw. 
8.  Reconnect the thermocouple to the connector. 
Figure 3-12  Thermocouple 
9.  Check that the thermocouple is free to move inside the hole and is in contact with the ceramic 
glass.  
NOTE  The spring will ensure a permanent contact between the thermocouple and the 
vitro-ceramic glass. 
 CAUTION!
10.  On the PLC screen, make sure the temperature reading of the new thermocouple is correct. If 
not, repeat Step 9. 
  If a good contact is not made between the thermocouple and the vitro-ceramic 
glass, the temperature reading will not be correct. 
Pressure 
Screw 
Connector 
Thermocouple 