Specifications
Maintenance  3-15 
Adjustment of the Dropped Board Detection Cell (optional) 
To adjust the dropped board detection cell: 
1.  Turn the power on by moving the Main Switch to the ON position. 
Figure 3-25 Emitter Cell 
Figure  3-26 Receiver Cell 
NOTES  The emitter cell (Figure 3-16) is at the input of the conveyor, it has only one red 
LED. This red LED should always be switched on and represents the status 
“under voltage”. 
The receiver cell (Figure 3-17) is at the output of the oven, it has 2 LED. The red 
LED indicates input status (red light on = object detected, red light off = no object 
detected), the green LED indicates signal quality. 
2.  For each cell, turn the adjustment screw to the max 
position, then adjust the physical position of the receiver 
or emitter until the green LED light is on. 
3.  Turn the adjustment screw counterclockwise until the 
green light is off (position A). 
4.  Turn the screw in the middle position between max and A.  
5.  Check for positive detection with the board.  
6.  Check against another board to make sure the adjustment 
is correct. 
Emitter Cell 
(conveyor input) 
Receiver Cell 
(conveyor output) 
Adjustment 