Specifications
4-2  Troubleshooting 
Alarms / Trouble  Possible Causes  Verifications and Actions 
Alarm Conveyor 2 – 
Speed Band Alarm 
Speed Sensor defective  Check the sensor position and compare to the pinion 
teeth. Check the wiring. 
AL2 too low  Increase the value of the alarm band. 
Bad calibration 
Recalibrate the conveyor (Refer to the TC V3 Operations 
Manual). 
High Temperature 
Alarm (AL1) 
Bad PID loop tuning   Perform an auto-tune procedure. 
Thermocouple defective  Check the thermocouple wiring and location. It should be 
in contact with the vitro-ceramic glass. 
Temperature Band 
Alarm (AL2) 
Bad PID loop tuning   Perform an auto-tune procedure. 
Thermocouple defective  Check the thermocouple wiring and location. It should be 
in contact with the vitro-ceramic glass. 
alarm band Value on recipe too 
small 
Increase the value in the receipt. 
Thermocouple Short 
Cut Alarm 
Thermocouple defective  Check the thermocouple wiring and location. It should be 
in contact with the vitro-ceramic glass. 
Bad PID loop tuning   Perform an auto-tune procedure. 
zone Fuse or circuit breaker 
down 
Check the fuse or the circuit breaker. 
Resistor broken  Check the resistor. 
Static Relay  Check the relay. 
Thermocouple Broken 
Alarm 
Thermocouple defective  Change the thermocouple. 
Defective wiring  Check the wiring. 
Security Bar Alarm 
Security bar not in place  Place the bar in the correct position. 
Sensor bad adjust  Adjust the sensor. 
Reflector broken  Replace the reflector. 
Open Hood Alarm 
Hood close sensor defective  Check the position and the wiring of the magnetic 
sensor. 
Circuit breaker/fuse of the 
electrical cylinder down 
Check the circuit breaker/fuse. 
Exhaust Alarm 
Air flow   Check the airflow and compare to the one specified. 
Increase the exhaust air flow if necessary. 
Flow pressure sensor defective  Check the wiring of the sensor, the pipe connection, and 
the adjustment screw. 
PCB spacing length is 
lower to PCB hole max 
length 
Recipe error  Correct recipe for having PCB spacing length higher 
than PCB hole max length.  
Loss Conveyor 
Parameters 
Conveyor parameters lost 
Recalibrate the conveyor (refer to the TC V3 Operations 
Manual). 
Dropped Board Alarm 
Board dropped 
1.  Stop the Oven. 
2.  Open it. 
3.  Remove the board. 
Photo cell defective 
Adjust the sensor (refer to the Conveyor Counter Cell 
Adjustment procedure) 
Check the wiring. 