Installation Instructions

FCC ID: PDCILM272XSW 6/19/02 DRAFT
Confidential Information 8 PN: 900-002x-000
© 2002 At Road, Inc.
All Rights Reserved
followed by SEND. The screen will timeout back to the INBOX after 15 minutes to prevent the
unit being accidentally left in this mode.
Information on the installer screen
The installer screen is designed to present the most important information in a clear, easy to
follow format. If you have feedback on the presentation of the screen then please pass this
back to @Road so that the screen information can be improved in future firmware releases.
The information presented covers :
Firmware version of the iLM
ILM serial number
Ignition sense state (ON/OFF)
CDMA signal and registration status
GPS status (whether making position fixes, and whether tracking satellites)
StatWhere switch status (ON/OFF)
Configuration of the Data2 accessory port.
Screen Layout
The screen shows information in the format shown below. If the screen appears grossly
different then you have an iLM with an earlier version of firmware, in which case you should
press the VIEW key to return to normal operation since none of the information on earlier iLMs
is useful to customer satisfaction group or for general installation purposes.
Most of this screen is quite intuitive. However, below is a complete description or the fields
and how they can help in troubleshooting an installed unit :
CDMA status values
Registered
: this is a normal operating mode. The modem has a good radio signal and is
registered.
Reg-wk-sig
: The CDMA modem is registered, and the iLM will operate normally, but the
radio signal strength is marginal. This is most likely due to poor CDMA coverage but could
also indicate a bad/damaged CDMA antenna.
Good signal
: The modem is not registered. The iLM will not transmit or receive data. If
the signal remains strong for several minutes, but the status does not change to
“registered” then there may be a problem with the IP address. Contact @Road customer
satisfaction and report the condition.
0.98 BE000123 IGN:OFF M:
GPS:in
-
fix(8B) SW:0000 D2:temp(24)
FW vers
Serial number
Ignition sensor Modem status
GPS status
# of satellites
trackin
g
StatWhere
switch status
Data2 configuration