Communications System Owner Manual
Table Of Contents
- Table of Contents
- ABOUT THIS DOCUMENT
- 1. INTRODUCTION TO CONNECTIVITY
- 2. COMMUNICATION SYSTEM NETWORKING (em AN OVERVIEW
- 3. TANDEM TIE TRUNK NETWORKS
- 4. MAIN-SATELLITE/TRIBUTARY (MS/T) NETWORKS THROUGH THE UDP OR MULTIPREMISES PACKAGES
- 5. ELECTRONIC TANDEM NETWORK (ETN) THROUGH THE ETN AND PNA PACKAGES
- 6. DISTRIBUTED COMMUNICATIONS SYSTEM (DCS)
- 7. DATA CONNECTIVITY - AN OVERVIEW
- 8. DATA COMMUNICATIONS CAPABILITIES
- 9. DATA COMMUNICATIONS CONFIGURATIONS
- A. RELATED DOCUMENTS
- B. SYNCHRONIZATION OF DIGITAL FACILITIES
- THE NEED FOR SYNCHRONIZATION
- SYNCHRONIZATION HIERARCHY
- CHANGES TO THE SCS SOFTWARE MADE AVAILABLE VIA SOFTWARE PATCHES
- NETWORK SYNCHRONIZATION AND ENGIINEERING
- AVAILABILITY OF SYNCHRONIZATION SOURCES
- CONCLUSIONS ON SYNCHRONIZATION
- USE OF GENERIC 2 AS A SYSTEM CLOCK REFERENCE
- USE OF GENERIC 1 AS A SYSTEM CLOCK REFERENCE
- C. TRUNKING TERMS AND CAPABILITIES
- D. COMMUNICATIONS PROTOCOLS
- E. LEAD DEFINITIONS
- F. NETWORKING FEATURES - AVAILABILITY MATRIX
- ABBREVIATIONS
- GLOSSARY
- INDEX
C-22 TRUNKING TERMS AND CAPABILITIES
_ ___________________________________________________________________________________________________________________________
_ ___________________________________________________________________________________________________________________________
_ ___________________________________________________________________________________________________________________________
_ ______________________________________________________________________________________
SWITCH A
FOR EACH "SWITCH A" TRUNKING OPTION (LISTED BELOW) — REFER TO THE
CORRESPONDING RECOMMENDED "SWITCH B" TRUNK OPTIONS (RIGHT FACING PAGE).
_ ______________________________________________________________________________________
GROUP/CALL TYPE DIREC- SUPERVISION SIGNALING
_ ____________________
TION
_ ________________________________________________________
GENERIC 2, GS LS RB E&M ISDN INCOMING OUTGOING TIMEOUT
SYSTEM 85, OR
DIMENSION PBX "ALERTING" "ADDRESSING" (NOTE 3)
_ ______________________________________________________________________________________
_ ______________________________________________________________________________________
26/WATS IN D-1
_ ________________________________________________________
19
_ ________________________________________________________
28 AUTO
_ ________________________________________________________
29 AUTO (NOTE 4)
_ ________________________________________________________
20 DMI-MOS (NOTE 5)
_ ______________________________________________________________________________________
_ ______________________________________________________________________________________
27/WATS OUT D-1 DIAL-TONE
_ ________________________________________________________
(DOD or 19
_ ________________________________________________________
TSPS Access) 28 IMMED-START
_ ________________________________________________________
29 WINK-START (NOTE 12)
_ ________________________________________________________
20 DMI-MOS (NOTE 5)
_ ______________________________________________________________________________________
_ ______________________________________________________________________________________
28/WATS-DOD OUT D-2 DIAL-TONE (NOTE 9)
_ ______________________________________________________________________________________
_ ______________________________________________________________________________________
30/DID IN 30 IMMED-START
_ ________________________________________________________
4 IMMED-START
_ ________________________________________________________
20 DMI-MOS (NOTE 5)
_ ______________________________________________________________________________________
_ ______________________________________________________________________________________
31/DID IN D-3 WINK-START
_ ________________________________________________________
11 WINK-START
_ ________________________________________________________
20 DMI-MOS (NOTE 5)
_ ______________________________________________________________________________________
_ ______________________________________________________________________________________
32/TIE IN D-4 IMMED-START
(DIAL-REPEATING)
_ ______________________________________________________________________________________
_ ______________________________________________________________________________________
33/TIE OUT 31 IMMED-START
(AUTOMATIC)
_ ________________________________________________________
27 ANALOG LINE
_ ______________________________________________________________________________________
_ ______________________________________________________________________________________
34/TIE OUT D-4 IMMED-START
(DIAL-REPEATING)
_ ________________________________________________________
1 GRD START
_ ______________________________________________________________________________________
Notes:
12. This trunk type and optional signaling arrangement may be used to build a "Special Access" trunk group. This trunk group and
signaling arrangement may function to provide trunking facilities for MEGACOM and SDN Services. Dependent upon trunk
type selection at the 4 ESS toll switch, wither DTMF or MF signaling hardware must be equipped.