User`s manual

Technical Information
Table 7-2. X.3 Parameters (continued)
Parameter Parameter Selectable Parameter Class*
Reference Description Values Meaning
Number R/W RO NI
11 Binary speed of 3 1200 bit/s
start-stop DTE 12 2400 bit/s
13 4800 bit/s
14 9600 bit/s
15 19200 bit/s
19 38400 bit/s
20 57600 bit/s
12 Receive Flow Control 0 None X
(DTE indicates to PAD) 1 Use of xon/xoff
127 EIA leads
13 Linefeed insertion 0 No line feed insertion X
after carriage return 1 Insert LF after transmission
of CR to DTE
from DTE
4 Insert LF after echo of CR to DTE
5 Combination 1 + 4
14 Padding after LF 0 No padding X
after linefeed
15 Editing 0 No editing X
1 Editing in Data Mode
16 Character Erase 0 None (off) X
8 Backspace (^H) X
35 #
127 DELETE
17 Line Erase 0 None (off) X
24 CAN (^X) X
21 NAK (^U)
64 @
18 Line Display X
19 Editing PAD 2 Editing PAD service X
service signals signals for display terminals
20 Echo Mask X
21 Parity Treatment 0 No checking or generation X
2 Parity generation
22 Page Wait X
101 Remote Loopback 0 Remote Loopback disabled X
1 Remote Loopback enabled
7-7