Instruction manual
MERLIN LEGEND Communications System Release 5.0
Installation
555-650-140
Issue 1
June 1997
Installing Telephones and Adjuncts
Page 3-43
Installing Direct Station Selectors
Installing Direct Station Selectors
The Direct Station Selector (DSS) is an optional piece of telephone equipment.
You can connect up to two DSSs to an MLX-28D or MLX-20L telephone that is
programmed as an operator console.
Considerations
Review the following items before you begin the installation procedure.
■ Connect the DSSs before you assemble the MLX telephones.
■ Auxiliary power is required under the following circumstances:
— An MLX telephone with an MFM and two DSSs requires a
406743419 power unit.
— An MLX telephone without an MFM, but with two DSSs, requires a
406943837 power unit, 400B adapter, and the D6AP cord
provided with the MFM.
— An MLX telephone with one DSS and an MFM requires a
406943837 power unit, 400B adapter, and the D6AP cord
provided with the MFM.
— If one carrier has three or more MLX telephones, each with a DSS
attached, use a 406943837 power unit, 400B adapter, and D6AP
cord for each MLX telephone and DSS after the first two.
■ The total length of cords between the KS22911-L2 or 406743419 power
supply and the MLX telephone must not be more than
50 ft. (15 m).
■ Do not replace the 2-ft. (61-cm) D8AC cord (packaged with the DSS)
with a longer cord. Improper operation may result.
■ Connect each KS22911-L2 power supply to an AC outlet that is not
controlled by a wall switch.