Control Unit Problems
Page 4-36
Module Problems
_____________________________________________________
* If any problem arises with the voice call on an NI-BRI module, run the NI-BRI
Provisioning Test next. While the BRI test is running, you can run the voice test on the
next module.
** Run the NI-BRI Provisioning Test on any NI-BRI module that is going to be used for data
calls or that had a problem with voice calls and was not previously tested with the tool.
Figure 4-6. Module Test Process
Check the equipment:
power supply
processor
(back up the system programming)
1
maintenance terminal
(use the PC when testing
MLX modules)
2
Check the error logs
3
Resolve any processor problems
4
Busy-out or reset the module
5
Run the Internal Loopback test
6
Check the error logs
7
Run the BchLoopback test
for MLX modules only
11
Replace the module if needed
9
Run the CSU Loopback test
for 100D modules only
10
Run the BRI Provisioning Test for
NI-BRI modules only
**
8
12
Restore the module
Record the errors on
the repair tag and
continue with the
next step.
errors
errors
errors
errors
Verify that voice calls can be made
on each BRI line
*