Control Unit Problems
Page 4-71
Module Problems
Console Display/Instructions Additional Information PC
Select the firmware to be programmed.
Select Yes.
If the firmware selected provides functionality that is different from the circuit
module’s current firmware, the Maintenance display indicates that a Board
Renumber will be required once the installation is complete.
Upgrade Slot
xx
: >
xx
= slot number entered in Step 3
aaaaaaaaaaaaaaaa Ver: aa
Line 2 displays the firmware version
Select one
currently installed on the module.
aaaaaaaaaaaaaaaa Ver: aa
aaaaaaaaaaaaaaaa Ver: aa
Lines 4, 5 and 6 display firmware
aaaaaaaaaaaaaaaa Ver: aa
versions available on the memory
Exit
card.
If an angle bracket (>) appears in the
upper right corner of the screen, you
may select More to display the next
screen with additional firmware versions
available on the memory card.
Upgrade Slot
xx
:
xx
= slot number entered in Step 3
Slot will be Busied Out.
Do you want to continue?
Yes
No
Exit
Upgrade Slot
xx
:
xx
= slot number entered in Step 3
Slot will be Busied Out.
Renum board when done.
Do you want to continue?
Yes
No
Exit