Maintenance and Troubleshooting
555-650-140
Issue 1
June 1997
Control Unit Problems
Page 4-78
800 NI-BRI Module Problems
Select Exit and repeat the upgrade procedure, being careful to select the
correct slot.
Board Memory Programming Failure
Console Display/Instructions Additional Information PC
Repeat the upgrade procedure. If the upgrade continues to fail after several
attempts, the module should be replaced. See “Replacing the Module.”
800 NI-BRI Module Problems
An 800 NI-BRI module requires running the Provisioning Test, in addition to the
other module tests, under the following circumstances:
If the module has data endpoints that use the BRI lines
If Voice Call manual testing of the module’s BRI lines indicates problems
The test described in this document supports the NI-1 BRI IOC Package “S”
service configuration. Multiline-Hunt Group/Series Completion testing is
included here.
See Figure 4-6
for a diagram of the entire module testing process. If you have
any questions about the 800 NI-BRI module that this section does not cover,
contact NSAC.