Instruction manual

MERLIN LEGEND Communications System Release 5.0
Maintenance and Troubleshooting
555-650-140
Issue 1
June 1997
Control Unit Problems
Page 4-80
800 NI-BRI Module Problems
Summary
To run the Provisioning Test, follow the steps below.
Busy-Out or Reset Before beginning the test, busy-out or reset the module
being tested. Both Busy-Out and Reset are in the Slot
menu, which you can access by doing the following from
the console:
Menu
MaintenanceSlot
See ‘‘Busy-Out and Reset’’, earlier in this chapter, for
additional information.
Console Procedure Menu
MaintenanceSlotDial the BRI slot no.
EnterProvisioning
PC Procedures Type the BRI slot no.
Appropriate Modules This test can be run only on 800 NI-BRI modules.
Time Estimate Approximately 20 minutes for a fully utilized board.
However, communication paths with errors increase the
time. Boards with fewer administered lines and no errors
decrease the time.
Interrupting the Test Interrupt the test by selecting
Exit.
Test Failure If the test fails, follow the instructions in Tables 4-6 and
4-7. If the module must be replaced, record the errors on
the repair tag and replace the module.
Restore Restore the module when it completes all module tests.
Restore is in the Slot menu, which you can access by
doing the following from the console:
Menu
MaintenanceSlot
See ‘‘Restore’’, earlier in this chapter, for additional
information.