Control Unit Problems
Page 4-82
800 NI-BRI Module Problems
Console Display/Instructions Additional Information PC
If the test cannot be run to completion, an error message screen
appears, such as the one shown below:.
Find the error message in Table 4-6
and proceed as indicated.
Table 4-6. NI BRI Provisioning Test Errors
Provisioning slot
xx
:
xx
= slot number entered in
Step 2
Test running too long
Exit
Error Messages Corrective Action
Slot is not busied-out Exit the test, busy-out the slot, and try again.
Slot empty or not valid Exit the test and try again. Be sure to type the correct slot
number; do not indicate an empty slot or the processor
(00). If the problem persists, replace the 800 NI-BRI
module.
Test running too long Exit the test. Remove half of the DSL connectors and
rerun the test. Note the result codes of those that fail and
then disconnect them. Reconnect the untested DSLs and
rerun the test. Note those that fail. Reconnect all DSLs.
Test won’t start
(applies to Release 4.1 and later)
Check that all BRI boards not being tested are busied out
and unplugged from the carrier. Run the test again.