Instruction manual

MERLIN LEGEND Communications System Release 5.0
Maintenance and Troubleshooting
555-650-140
Issue 1
June 1997
Control Unit Problems
Page 4-85
800 NI-BRI Module Problems
Interpret the test results
If the test completes successfully, the module’s B-channels are
functioning properly. If a communication path fails, find the result code in
Table 4-7
, and proceed as indicated.
Restore the module when all tests are completed.
When all of the lines have passed the test, the red LED will remain on
until the CO reinitializes all of the lines.
Follow the procedures in Table 4-7
for examining each BRI line that has
an error and make corrections, if necessary, before rerunning the tool.
Continued on next page
Table 4-7. NI-BRI Test Result Codes
Result
Code
Description Corrective Action
OK
(Release
4.0 and
earlier)
BRI facility
provisioned with
functioning voice and
data capabilities
No action required if voice and data functionalities
are expected.
CO-V CO provisioning
error for voice calls on
that facility
The facility is correctly administered and
established on Layers 1, 2, and 3. However, a
problem associated with the provisioning at the CO
for voice calls was detected.
If the facility is intended to provide voice calls,
perform the following tests (described later in this
section) and record the results before contacting
the LEC:
Outgoing Voice Call Test
Incoming Voice Call Test