Control Unit Problems
Page 4-97
800 NI-BRI Module Problems
Table 4-7 Continued
Result
Code
Description Corrective Action
LAYR2 LAYER 2 BRI
Provisioning error
on facility
Layer 1 is established. Unplug the connector and replug
it into the same port. Rerun the test. If the problem
persists, contact the LEC.
The possible causes of this problem are:
The DSL is provisioned with only one active DN
(rather than two) at the CO.
Two lines are administered when only one line is
provided by the CO.
Check that the facilities are administered properly and
rerun the tests if you made any corrections.
LAYR3 LAYER 3 BRI
Provisioning error
on facility
Layers 1 and 2 are established.
This result indicates that the CO does not do Layer 3
initialization. This error may not affect service, but the
LEC must be contacted.
NOTST Testing was not
performed on this
facility because no
other Layer 3
initialized facility
was available in the
time allowed for
testing
Layers 1, 2 and 3 are established. Correct the known
problems on the other facilities and rerun the test.
????? Testing was
inconclusive
because the line(s)
used to test this
one had problems
Correct the known problems on other facilities and rerun
the test.