Instruction manual

MERLIN LEGEND Communications System Release 5.0
Maintenance and Troubleshooting
555-650-140
Issue 1
June 1997
Error Logs, Access Logs, and System Inventory
Page 2-2
Error Logs
Checking the Error Logs
Once you have reviewed the error logs, you should print the error
information.This will help you determine whether your work has resolved each
problem. (Refer to “Summary” below or
System Programming
for additional
information about printing.)
Summary
Console Procedure Menu
MaintenanceSystemError
Log
Last 30 or Permanent or Transient
NOTE:
Prior to Release 4.0, the error log displays only the
last 10 messages.
PC Procedure
or or
Table 2-1. Transient/Permanent Error Thresholds
Error
Code Error Description
Transient/Permanent
Threshold
7402 LOOP BIT CONTROL NOT SET 4
7403 NO LOOP CURRENT 4
7404 STUCK RINGING 2
8403 NO EXTERNAL RELEASE 2
840B NO LOOP CURRENT 4
840C STUCK RINGING 2
840D INCORRECT FIRMWARE STATE 2
2E01 T1 ACC VIOL 10