Table 2-2. Error Codes
Error
Codes Description Action
0001 TIMEOUT COLD START:
System programming is okay.
No action required; however, if problem
persists, troubleshoot the processor.
0002 POWER UP WARM START:
System programming is okay.
No action required; however, if problem
persists, troubleshoot the processor.
0003 SOFTWARE COLD START:
System programming is okay.
If problem persists, troubleshoot the
processor.
0004 SOFTWARE WARM START: System
programming is okay.
If problem persists, troubleshoot the
processor.
0005 Reset - DIAGNOSTIC SWITCH:
0006 INCOMPLETE COLD START:
System was cold-started while a
restart was in progress.
If problem persists, troubleshoot the
processor.
0007 SANITY TIMEOUT RESET:
Faulty software, module, carrier, or
processor sanity timer.
Troubleshoot module and or processor.
0008 MAX RESET COUNT EXCEEDED:
System was cold-started (System
Reset) because too many warm
starts occurred.
System programming is okay.
If problem persists, troubleshoot the
processor.