Error Logs, Access Logs, and System Inventory
Page 2-8
Error Logs
Table 2-2 Continued
Continued on next page
Error
Codes Description Action
0012 INVALID RESET FLAG:
Processor problem.
Troubleshoot the processor.
0013 DUART STREAMING INT:
Processor problem.
Troubleshoot the processor.
0014 PROCESSOR ERR INTERRUPT:
Processor problem.
Troubleshoot the processor.
0015 MODULE MISMATCH:
Physical and logical type mismatch.
Module inserted into wrong slot.
Change system programming to reflect
the proper module or install the proper
module.
0016 POWER UP COLD START:
A module dual port RAM failure was
detected.
System programming is okay.
If problem persists, troubleshoot the
module for the slot indicated.
0017 REAL TIME CLOCK FAULT:
Date and/or Time incorrect or
non-readable.
If this problem persists, replace the
processor module.
0018 RTC COLD START:
This error is not displayed.
0019 RESET TIME & DATE:
The system performs a cold start
because the real time clock chip is
not working correctly.
If this problem persists, replace the
processor module.
0401 ABK CARD NOT INSERTED:
A PCMCIA memory card for
Translation is not inserted.
Insert a Translation card or a card that
has not been formatted.
0402 ABK INCORRECT CARD TYPE:
A PCMCIA memory card for
non-Translation is inserted.
Remove the current card and insert a
Translation card or a card that has not
been formatted.