Instruction manual
MERLIN LEGEND Communications System Release 5.0
Maintenance and Troubleshooting
555-650-140
Issue 1
June 1997
Error Logs, Access Logs, and System Inventory
Page 2-9
Error Logs
Table 2-2 Continued
Continued on next page
Error
Codes Description Action
0403 ABK CARD WRITE-PROTECTED:
The Translation card has the write
protection switch on.
Flip the write protection switch on the
card to off (non-write protect
mode/position.) It this problem persists,
try another card, then replace the
processor module if the problem
remains.
0404 ABK EXTENSION BUSY:
A station is in program,
administration, or maintenance
mode.
Wait until the station changes mode.
Make sure the programming device
(SPM or the console) is not in
programming mode when autobackup is
scheduled to occur.
0405 ABK FAULTY CARD:
Unknown cause of a bad card.
Reset card and retry. It the problem
remains, try another card. If the problem
still remains, replace the processor
module.
0801
and
1C07
and
5801
CTI LINK DELETED:
A board renumber or slot restore
moved the CTI Link to an
unacceptable port and the system
has removed the link.
Check that the following are true:
1. The system is in Hybrid/PBX mode.
2. The link is on an 008 MLX or 408
MLX board.
3. The MLX board firmware vintage is
not 29.
4. Board renumber has not moved the
extension to an operator positon.
5. An MLX telephone is not connected
to that port.
6. Board renumber has not moved the
MLX extension to the system
programming port.