Error Logs, Access Logs, and System Inventory
Page 2-10
Error Logs
Table 2-2 Continued
Continued on next page
Error
Codes Description Action
0C01 NO I-VMS PORT IN SERV:
This error indicates that the VMS
machine may be down.
No action required.
0C02 DID INTERDIGIT TIMEOUT:
May be noisy line or central office
problem.
No action required. If problem persists,
troubleshoot the DID line and inform the
central office if necessary.
1C01 POOL M-BUSY EXCEEDS 50%:
More than half the trunks in the pool
are busy.
Troubleshoot trunk.
1C02 DPR TEST NOT COMPLETED Slot did not complete initializing.
1C03 FW UPGRADE ATTEMPT: No action required.
1C04 FW UPGRADE COMPLETE: No action required.
1C05 INVALID FMW 29 DETECTED:
Incompatibility problem. The
specified video endpoint or UDM is
connected to an 008 or 408 GS/LS
MLX with firmware vintage 0x29.
Replace the 008 or 408 MLX board with
one of another firmware vintage and
retire this permanent alarm manually.
1C06 BAD BOARDS IN SYSTEM:
At least one incompatibility problem
of type HER 0x1c05 detected. Turns
on CPU red LED.
Replace the 008 or 408MLX board with
one of another firmware vintage and
retire this permanent alarm manually.
1C07 see error code 0801
2C01 T1 ACCESS VIOLATION:
T1 Services (Channels-Voice/Data)
administered incorrectly.
Check facility provisioning and
reprogram channels appropriately for
voice or data. If the problem persists,
contact the NSAC.