Instruction manual

MERLIN LEGEND Communications System Release 5.0
Maintenance and Troubleshooting
555-650-140
Issue 1
June 1997
Error Logs, Access Logs, and System Inventory
Page 2-13
Error Logs
Table 2-2 Continued
Continued on next page
Error
Codes Description Action
6C09 DS1 MISFRAME ALARM:
Misframe count reached 18.
Troubleshoot the T1 trunk. If problem
persists, escalate to your technical
support organization.
MaintenanceSlotError
EventsCurrent hr
6C0A DS1 SLIP ALARM:
Slip count reached 88.
Troubleshoot the T1 trunk. If problem
persists, escalate to your technical
support organization.
MaintenanceSlotError
EventsCurrent hr
6C0B HARDWARE INOPERATIVE:
Hardware is not operating properly. If
this is the only 100D (DS1) or 800
CO-BRI module, or if this is the
module designated to have the active
clock, its TDM bus clock generator
was not activated.
If problem persists, escalate to your
technical support organization.
6C0C BRI LOSS OF SYNC: Usually no action is required.
Troubleshoot the BRI trunk. If problem
persists, contact your technical support
organization.
6C0D BRI NET DEACTIVATED: Usually no action is required. The link
should return to normal once the test is
completed. If problem persists, contact
your technical support organization.
6C0E BRI NET INV 2B+D LB ACT: Usually no action is required. The link
should return to normal once the test is
completed. If problem persists, contact
your technical support organization.