Error Logs, Access Logs, and System Inventory
Page 2-17
Error Logs
Table 2-2 Continued
Continued on next page
Error
Codes Description Action
7802 SANITY INT NOT GENERATED:
Only applies to modules that have
extension jacks.
Reset the board
.
If problem persists,
troubleshoot the module.
7803 NO PORT BOARDS AVAILABLE:
This error is reported when modules
are not present.
No action required. Delete this entry from
the transient log.
7804 INVALID SANITY RESPONSE:
This error occurs when a sanity test
gets invalid responses. Applies only
to modules that have extension
jacks.
Reset the board
.
If problem persists,
troubleshoot the module.
7805 INVALID SLOT NUMBER:
Rarely occurs.
Software could not process an event
detection because the slot number
was invalid.
No action required; however, if problem
persists, restart the system.
7806 NOT IN STANDBY MODE:
Reported during cold start or
background check.
Reset the board
.
If problem persists,
troubleshoot the module.
7807 SELF TEST NOT COMPLETED:
Reported during cold start.
Reset the board
.
If problem persists,
troubleshoot the module.
7808 TEST RESULT REGISTER BAD:
A module error or processor error
resulted while running test.
Reset the board. If problem persists,
troubleshoot the module.
7809 TEST STATUS REGISTER BAD:
A module error or processor error
resulted while running test.
Reset the board. If problem persists,
troubleshoot the module.