Instruction manual
New Programming Options
4-19
100R INA and 100 DCD Modules
■ Inverting the clock
Assigning a Data Rate 4
The data rate is factory-set to 56 kbps. It can be reached by using the following
sequence:
Console Procedure SysProg
→Start→Lines and Trunks→
More→ More→CSU/DSU→Type Slot no.→
Enter→ Data Port→Type por t
no.
→Enter→Rate→Select
56 kbps or 64 kbps
→ Enter
PC Procedure
→→→More→More→→Type Slot
no.
→1→→Type port no.→ 1→
→
Select 56 kbps or 64 kbps→ 1
Assigning Channels to the Data Port 4
Assign the channels to each data port by using the following sequence:
Console Procedure SysProg
→Start→Lines and Trunks→
More→ More→CSU/DSU→Type Slot no.→
Enter→ Data Port→Type por t
no.
→Enter→Channel→Type channel no.→
Enter
Note: Each channel must be entered individually
followed by Enter.
PC Procedure
→→→More→More→→Type Slot
no.
→1→→Type port no.→1→
→
Type channel no.→ 1
Note: Each channel must be entered individually
followed by
1.
These procedures are available only for the 100 DCD module.