Instruction manual
Error Codes
9-11
Maintenance and Troubleshooting
0013 DUART STREAMING INT:
Processor problem.
or
The system was powered
down incorrectly; for
example, carrier 2 was
powered down before carrier
1. If errors exist because of
the improper power-down,
no action is required.
Check processor.
0802 E911 OVERFLOW
One of the following has
occurred:
■ All lines assigned to
E911 Partition or Adjunct
are busy or bad.
■ No lines are assigned to
E911 Partition or
Adjunct.
■ No physical line is
connected to the system,
the network, or the E911
Adjunct.
Do the following:
■ Make sure the proper
number of trunks are
assigned to E911 Partition or
Adjunct.
■ Assign lines to E911
Partitions or Adjunct.
■ Check that ground-start or
loop-start trunks are
connected to the E911
Adjunct.
■ Check the network interface
connection.
When the condition returns to
normal, the external alarm turns
off automatically. You must
remove the entry from the
permanent error log.
Table 9-2. Error Code Descriptions—Continued
Error
Code
Description Action