Installation guide

Tone Routing
Programming Steps
Whatever zones are selected here will receive the tone selected in the
previous option, "Tone Selection."
For example, you have optioned an input zone to receive a doorbell
pushbutton input. And you have selected a tone (in the previous step) to
be output when the doorbell input is received. Now you must select the
output zone or zone group which will receive the tone.
First access the PagePac Plus system and enter the programming mode
by pressing [
* ] [ * ] and entering your Programming password (if optioned).
You may exit the programming mode by dialing [
# ].
1.
2.
3.
Dial [
9
] [
4
] to activate Tone Routing.
Hear a DOUBLE beep.
Enter the input zone number. Use ALlAS numbers, if optioned.
Otherwise, use Physical zone/group numbers.
Hear a DOUBLE beep.
Enter the output zone/group ALlAS number.
Hear TRIPLE beeps.
To verify Tone Routing, dial [
9 ] [ 5 ] and repeat steps 2 and 3 above.
Table 2-23 summarizes these actions.
Table 2-23. Tone Routing
Feature
Mode Option/
Verify
Dial
Listen
For
Zone/Group
Selection
Listen
For
Choose Option
Listen
For
Default
Tone
Routing
To Select
To Verify
94
95
Double
Beep
Enter the input
zone number
Double
Beep
Output
zone/group
number
Triple
Beeps
None
Programming The Controller
2-33