User`s guide

5.
6.
7.
Plug one end of the power cord into the 10 VAC power connection on the
SPIRIT Attendant.
Plug the other end into a 120 VAC outlet.
The power light goes on. If the battery light flashes, announcements have not been
programmed. (For a complete description of error codes, see Table 3-1 on page 3-3.)
Reset the setup switches as described in Table 1-5.
TABLE 1-5. Switch Settings When Operating Unit.
Switch Setting
Result
1
On
Saves recorded
announcements during
power outage
2
On
Saves routes and
programmable features
during power outage
3
Off
Does not use battery backup
to answer calls during
power outage (See NOTE)
4
Off
Not used
NOTE:
During a power outage there is no need to use battery backup to
answer calls if the SPIRIT Attendant shares an Uninterruptible Power
Supply (UPS) with the SPIRIT system control unit. If a UPS is not
used with the control unit, incoming calls cannot be answered by the
system during a power failure and therefore cannot be directed to the
SPIRIT Attendant.
1-10
Installation Requirements