m a n u a l A200SOV Open vent heat only boiler 8G.52.70.00/12.10 Changes reserved.
Content 1. Introduction..................................................... 3 2. Safety............................................................. 5 3. Boiler description............................................ 6 4. Display and function keys............................... 7 4.1 The Reset key.......................................... 7 4.2 Setting the heating water temperature..... 8 4.3 Requesting current data........................... 8 5. Filling the heating system...............................
Introduction These operating instructions describe the functioning and the operating of the ATAG A boilers. This manual is for the end user. For installation and servicing there is an installation & servicing instructions manual for the installer. Read this manual fully before operating the boiler. In case of doubt or errors contact your installer. ATAG Heating reserves the right to change the specifications and dimensions without prior notice.
The Benchmark Scheme ATAG Heating UK Ltd is a licensed member of the Benchmark Scheme which aims to improve the standards of installation and commissioning of domestic heating and hot water systems in the UK and to encourage regular servicing to optimise safety, efficiency and performance. Benchmark is managed and promoted by the Heating and Hotwater Industry Council. For more information visit www.centralheating.co.
Safety Work on the installation should only be carried out by qualified personnel with calibrated equipment. When replacing parts, only ATAG Service components may be used. If you smell gas: - No naked flames! No smoking! Do not switch lights on or off or use other electrical switches. Do not use the phone Close the gas mains Open windows and doors Warn the occupants and leave the building Only call the gas company or installer once you are outside the building.
3 Boiler description The ATAG A is a closed, condensing and modulating heating boiler which meets the European standard (CE). A declaration of conformity can be obtained from the manufacturer. ATAG A-Serie Example SEDBUK ClassA 6 The efficiency of the boiler is very high and the radiation convection and standby losses very low. The emission of noxious substances is far below the fixed standards so the boiler is SEDBUK Class A rated.
4 Display and function keys The boiler is equipped with a door at the front. After opening the door you will find a brief overview of the meaning of all the keys and icons. These are described below. Indicator for heating Boiler operational Error indication Request for heating Service mode or Blocking % bar °C Information key + i + ( OK ) Setting of boiler temperature n.a. - R - ( ESC) Reset key Reset-key + - ii R + - The reset key restarts the boiler after a malfunction has occurred.
4.2 Setting the heating water temperature + ii + - R - ATAG A-Serie 4.3 8 Press + or - ; The display will show the set value while flashing; Press + or – to change the set value. Each change becomes active directly. Heating program OFF: Press – until the lowest value is reached and then press – again. The display is showing -- and the upper is off. Switching on works in reverse order.
5 Filling the heating system This boiler is part of an 'Open Vent' heating system. The system is not pressurized, but is filled automatically by a filling system in the loft. If there is a problem with this system, please contact your installer. When the heating system is filled and after a power interruption the boiler will be reset and starts with a venting program. After the venting program (display shows c1 05) of approx. 7 minutes has ended, the boiler will be operational again.
7 Errors In the event of a failure (this is indicated by a c and number code on the display) you can try to eliminate the failure by pressing the Reset key. If the failure persists, please contact your installer as soon as possible and tell him the number code. There are also messages with a c and a number code that constitute no failures. These messages will cancel themselves over time.
ATAG A-Serie
E. & O. E. This renewed publication cancels all previous installation instructions. The company reserves the right to change the specifications and dimensions without prior notice. ATAG Heating UK Ltd. • Unit 3 • Beaver Trade Park • Quarry Lane • Chichester • West Sussex • PO19 8NY Phone: 01243 815 770 • Fax 01243 839 596 • E-mail: info@atagheating.co.uk • Internet: www.atagheating.co.