OPERATING INSTRUCTIONS Reliability Innovation 8G.52.25.00/03.
operation indication: + not visible when passing the day and date indication "eco-temperature" * visible during "day program" and actual room temperature in degrees Celcius (°C) "party program" °C is blinking if boiler is on blinking when set on "continuous heating" visible during "night program" and "absent program" blinking when set on "continuous lower" time indication * Eco temperature means that the boiler will not come into operation if the outside temperature does not exceed the set value (s
Table of contents Keyboard layout ......................................................................................................................................................................................... 2 Introduction ................................................................................................................................................................................................ 4 In brief a number of simple actions for daily use ................................
Operating the program keys ................................................................................................................................................................. Time and date .................................................................................................................................................................................... Standard timer programs for heating ............................................................................................
Introduction The ATAG Brain timer thermostat is an advanced digital timer thermostat, in which the most recent computer technology has been incorporated. The ATAG Brain has been specially developed for use with the ATAG S-HR heating appliance. The heating appliance passes on a number of unique features to the ATAG Brain timer thermostat. The ATAG Brain is unique in that in contrast to a standard timer thermostat it has fewer switch-on moments.
Your heating and hot water supply (if present) are controlled according to time settings (timer program). Timer program 1 is always active from the factory. It is then possible to select 2 other timer programs. The times and temperatures can be changed within the timer program. A number of factory settings are, for example: Day temperature: 21°C Night temperature: 15°C Timer program 1: 07.00 - 10.00 hours 19°C 10.00 - 17.00 hours 19°C 17.00 - 23.
In brief a number of simple actions for daily use. Wish: Action: You want to temporarily increase or decrease the temperature in the room. - More info on: or key until DESIRED TEMP is displayed. Press Using the same keys you can increase or decrease the temperature. Open or close any thermostatic valves (if present) more. page 10 You want to have the heating on for longer in the evenings (e.g. party, a visit overruns). - key for 4 seconds until PARTY TILL is displayed.
You want to have the night temperature continuous for an indefinite period. - key for 6 seconds until LOWER CONT is displayed. When you Press the release the key, the heating will maintain the night temperature for an indefinite period of time ( flashes). page 9 Manual operation. - By selecting HEATING CONT or LOWER CONT, as described above, it is possible to manually regulate the temperature 24 hours a day using the and keys.
On the following pages Operating the front keys there follows an accurate description of each key Using the keys on the front of the thermostat you can retrieve, adapt and remove interim settings. and its function. Functions: - By keeping the display changed temperature (if adjusted) switch off holiday program (if activated) activate automatic program set party program activate continuous heating key depressed you can "scroll" through the functions.
- Changed temperature CHANGE TEMP °C 18.0 This window appears on the display if the temperature is adjusted in the intervening time. The temperature setting is only applicable for the active time block. See page 12 for changing time blocks. The temperature setting for the next time block is that for the basic timer program. For making interim changes to the temperature, see page 10.
- Party program PARTY TILL 02.10 Using this function you can extend heating, outside the timer program. As soon as you activate the program, the switch-off time is set 10 hours later than the current time. Using the and keys you can change the required switch-off time in increments of 30 minutes. See page 10 to select the desired temperature whilst the program is on. By standard, the set day temperature applies (see page 19).
Functions: The functions under the key are, if required, permanently displayed on the display. To do this you should keep the key pressed for 10 seconds for the function in question. Return to the standard display by pressing the key as often as necessary.
Functions: By keeping the display changed temperature (if adjusted) switch off holiday program (if activated) activate automatic program set absent program activate continuous decrease key depressed you can "scroll" through the functions. The function selected on the display becomes active after releasing the key.
- Changed temperature CHANGE °C TEMP 15.0 This window appears on the display if the temperature is adjusted in the interim. The temperature setting only applies for the active time block. See page 12 for adjusting the time blocks. For the next time block the temperature setting is that of the timer program. See page 10 for interim adaptation of the temperature. HOLIDAY - Holiday program AUTOMATIC - Automatic Only if the "Holiday" program is active does this window appear on the display.
ABSENT TILL 15.00 - Absent program You can use this program if you are absent for a specific period of time and do not wish to use the heating. Using this function the time can be set at which the heating appliance has to follow the timer program again. Using the and keys set the desired time. The time setting is increased or decreased in increments of 30 minutes. The desired temperature up to the set time becomes the set night temperature (see page 19).
and Function: - past load (activate the DHW if it is switched off in accordance with the timer program). PAST LOAD DHW ON - Past load Press the and keys at the same time. The words "Past load DHW" appear on the display. When the program is "ON", the DHW continues to heat the water for a maximum of two hours up to the basic temperature of 63°C. The program can be switched off within two hours. Call the function using the off the program using the ATAG timer thermostat page 9 key.
or Function: - interim increase / decrease of the temperature - Desired temperature DESIRED °C TEMP 18.0 Press the the display. or key. Keep the key depressed. After two seconds the words "Desired temp" appear on Press the key to increase the temperature. Press the to decrease the temperature. The set temperature continues to be maintained during the time block valid at that time. The temperature setting is that of the timer program for the next time block.
and Functions: - selecting a timer program for heating - Selecting timer program for heating HEATING PROG -1- Press the and on the display. key at the same time in the selected timer program (1, 2 or 3) so that heating appears Select the desired timer program using the or See page 12 for the settings of the timer program. ATAG timer thermostat page 10 key.
Operating the program keys If you open the pull-down cover of the Brain, you will come across 6 digit program keys there. Using these keys you program the settings, which determine how the heating installation operates. The thermostat is pre-programmed in the factory. Your installer will then go on to set the adjustments for your installation. You only have to program the thermostat if you want alternative settings. Using the "front" keys meanwhile it is possible to deviate from the set values.
Function: - programming time and date The correct time and date have been set in the factory. The ATAG Brain has automatic time correction for summer and winter time. If you want to change time and date, then you should do the following: - Time and date TIME 21:30 Press the Press the key once. The current time can be set. or Press the DATE 08 Press the ATAG timer thermostat page 11 key, until the correct time is displayed. key again. The correct day can be set.
MONTH JUL Press the 07 or Press the YEAR 1996 Mo 08.jul '96 14:05 Press the key again. The correct month can be set. °C 19.5 Press the key, until the correct month is displayed. key again. The correct year can be set. or key, until the correct year is displayed. After entering the time, date and year, press the The standard display becomes active. key again.
Function: First set the "Day temperature" (see page 19) before you set the timer program. Subsequently setting the day temperature affects the temperature set in the timer program. - programming time and temperature for heating in timer program Standard timer programs for heating The ATAG Brain is provided with 3 independent timer programs for the time and temperature settings for the central heating. You can set three time blocks per day per timer program, independently over seven days.
- Setting time and temperature for heating HEATING PROG -1- HEATING PROG 07.00 -- 10.00 day - time block and key at the same time in the selected timer program (1, 2 or 3) so that the heating appears on the display. Then press the key. Press the display. key to change the settings for a timer program. The words "Heating prog" appear on the Press the key again.The first time block for Monday is displayed, wherupon the switch-on timeflashes.
10.00 -- 17.00 Mo-2 °C 19.0 After you have set time block 1, you press the key again and the second time block (Monday) appears on the display. After you have entered the settings for this, you press the key again and then enter the data for the third time block. Be sure of continuous time blocks. For noncontinuous time blocks, the thermostat sets the night temperature for the intervening periods. 10.00 -- 17.00 Tu-1 °C 19.
Function: - copying the time and temperature settings When setting the program times, it is possible to copy a day setting to a next day or copy an entire week. 07.00 -- 10.00 Mo-1 °C 19.0 Mo --> week - Copying a week Using the Press the key, select the first time block of the day that you want to copy. key. The words "Week" and "COPY" appear on the display. COPY Mo --> week --OK-- COPY Press the key. The words "COPY" and (below to the left) "OK" appear on the display.
07.00 -- 10.00 Mo-1 °C 19.0 Mo --> week - Copying a day Using the key, select the first time block of the day that you want to copy. Press the key. The words "Week" and "COPY" appear on the display. Press the key again. The word "Week" is replaced with "Tu" (Tuesday) on the display. Using the key, select the day to which the settings have to be copied. COPY Mo --> Tu COPY Mo --OK-- --> Tu COPY Press the key if the correct day has been selected.
and First set the DHW temperature before you set the timer program. The default setting is 63°C. Subsequently setting the DHW temperature affects the temperature set in the timer program. Timer program 1 Timer program 2 Timer program 3 Function: - programming time and temperature in the timer program for hot water Standard timer programs for hot water The examples below apply for a heating appliance with an indirectly heated boiler, fitted with a temperature sensor.
- Setting time and temperature for hot water DHW PROG 1 Before setting the timer program for hot water, first select the timer program to be changed. Press the key until the words "DHW Prog" appear on the display. Select the desired timer program using the ADJUSTMENT Press the or key. key to store the settings in the memory. "Adjustment CH" appears on the display.
HOTWATER PROG -1- switch-on time - switch-off time 00.00 -- 23.55 Mo-1 day - time block °C 63.0 temperature Press the key, by pressing the the number of the selected timer program. Press the key. The first time block for Monday is displayed. The switch-on time, switch-off time, day, the timer program and temperature can be seen on the display. The switch-on time flashes. By pressing the or key you can set the required switch-on time. Press the to the required switch-off time and temperature setting.
00.00 -- 00.00 Mo-2 °C 63.0 After you have set time block 1, you press the key again and the second time block (Monday) appears on the display. After you have entered the settings for this, you press the key again and time block 3 appears for Monday. If, after setting the last time block for Monday, you press the key again, you can enter the data for the first time block for Tuesday. Program the settings for the different time blocks. 00.00 -- 23.
Functions: - ADJUSTMENT CH setting adaption setting heating line setting day temperature setting night temperature setting DHW temperature (external DHW cylinder with temperature sensor) selecting timer program for hot water setting temperature correction select language reset the factory settings Press the key. The words "Adjustment CH" appear on the display. This means that you are going to make settings relating to the operation of the CH boiler. key, the following setting options appear.
ADAPTION CH ON - Setting adaption This setting is not applicable for the function "Room sensor OFF". The ATAG Brain timer thermostat calculates, when adaption is "ON", its most efficient heating line, which is necessary to create sufficient heat for the installation. Using this self-learning adjustment, the heating line value will flash and automatically change the value. key again.
HEAT LINE CH 1.75 The heating line should only be changed in the case of installations, which differ greatly. After changing the heating line, ensure that the "Adaption" function is set to "OFF" (see page 17). - Setting heating line This function can only be changed when adaption is "OFF". Press the key until the words "Heat line CH" appear on the display. The ATAG Brain timer thermostat calculates, when adaption is "ON", the optimum setting for the heating line (K-factor) for your heating appliance.
Heating line settings graph Indication 110 2.75 3.00 3.25 3.50 2.50 K-factor 2.25 100 radiators, air heating, convectors 2.30 radiators, under-floor heating as supplementary heating 1.75 under-floor heating, radiators as supplementary heating 1.50 under-floor heating 1.00 2.00 90 1.50 70 Flow temperature in ° C aanvoertemperatuur in °C 1.75 80 Standard setting : 1.75 Setting range : 0.20 - 3.50 1.25 60 1.00 50 0.75 40 0.
- Setting day temperature DAY TEMP CH °C 21.0 Increasing or decreasing the day temperature has implications for the temperature set in the time blocks of the timer program. The number of degrees which is set above or below 21°C, will also be added or deducted for the temperature settings of the timer program. Press the key until the words "Day temp CH" appear on the display. You can set the day temperature using this function. This is the basic value for the timer program.
NIGHT TEMP CH °C 15.0 - Setting night temperature Press the key until the words "Night temp CH" appear on the display. You can set the night temperature using this function. The value set here is also the setting for the "Absent program", "Continuous decrease" functions and for noncontinuous time blocks in the timer program. Using the or keys you can set the desired night temperature.
DHW TEMP - Setting DHW temperature °C 63 Increasing or decreasing the DHW temperature has implications for the temperature set in the time blocks of the timer program. The number of degrees which is set above or below 63°C, will also be added or deducted for the temperature settings of the timer program. (Only for heating appliances with an external DHW fitted with a temperature sensor). With this function you may set the basic temperature for the DHW.
- Selecting timer program for hot water DHW PROG 1 Before you set the timer program for hot water, first you must select the timer program to be changed. Press the key until the words "DHW Prog" appear on the display. Select the desired timer program using the or key.
CORRECTION 19.5 °C 00.0 K corrected temp.-correction - Setting temperature correction Press the key until the word "Correction" appears on the display. A correction can be made to the measured room temperature. This may be necessary for example when the room thermostat is mounted on a poorly insulated wall, as a result of which the thermostat measures a different temperature from that which actually prevails in the room. Set the value for the correction using the and keys.
- Select language GB / D GB 1 Press the key until the words "GB / D" appear on the display. Select the language using the or key. Standard setting : GB Setting range : 1 = English : 2 = German RESET- ADJ - Reset the factory settings Using this function you can undo any changes made to Master thereby activating the factory settings. Press the key until the words "Reset-Adj" appear on the display. Press the and keys at the same time until the word "OK" appears on the display.
and During this period the thermostat is set to 10°C (the minimum room temperature, if room sensor is "ON"). If room sensor is "OFF", the boilers frost protection always takes effect given an outside temperature of 3°C. ADJUSTMENT Functions: - holiday program - Holiday program You can set a holiday period on the timer thermostat using this function. Press the key. The the words "Adjustment CH" appear on the display . Press the key. The the words "Holiday CH" appear on the display .
HOLIDAY FROM 19.08 HOLIDAY TILL 20.09 key. The the words "Holiday from" appear on the display. Press the Set the starting date of the holiday using the and keys . Press the key. Set the correct month using the Press the key. The display shows the text "Holiday till". Set with the and Press the Press the and keys. keys the end date of the holiday. key. Set with the and keys the correct month. key to store the settings in memory. The display shows the text "Holiday CH".
Messages on display It is also possible for a number of messages to appear on the timer thermostat. The messages, which appear on the display provide information about the operation of the boiler. In some instances the boiler anticipates an impending fault and passes this on to the timer thermostat so that steps can be taken before the boiler comes into operation. In addition, eventual error codes are passed on.
ATAG timer thermostat page 23 MESSAGES
Notes
ATAG timer thermostat page 24 NOTES