Operation Manual

99
INSTALLATION GUIDE built in HL60..E
The appliance can be connected in the following ways:
1 phase connection (1 1N a.c. 230 V / 50 Hz):
The voltage between live and neutral is 230 V a.c.
Install connecting bridges between connection points 1-2 and 4-5.
Your group must be protected by a fuse of at least 32 A. The connecting
power cable must have a minimum core cross section of 6 mm
2
.
2 lives with 2 neutrals connection (2 2N a.c. 230 V / 50 Hz):
The voltage between live and neutral is 230 V a.c. There may be a
voltage of 0 V between the phases if they are connected to the same phase in
the meter cupboard but also 400 V if they are connected to 2 different
phases. Your groups must be fused with at least 16 A (2x). The connecting
power cable must have a minimum core cross section of 2,5 mm
2
.
Electrical connection
For the connection, use an approved cable, in accordance with the
regulations. The cable casing should be of rubber.
There is a label on the underside of the appliance with the wiring
diagrams. The connection terminals are accessible once you have opened
the junction box on the underneath. The junction box cover can be
opened with a screwdriver.
If you want to make a fixed connection, make sure that a multi-polar
switch with a contact separation of at least 3 mm is fitted in the supply
line.
Power setting table
98
Type of hob
HL60..E
Cooklight
x
Electrical connection
230 V - 50 Hz
x
Power of element
Front left
2300 W
Rear left
1200 W
Rear right
2000 W
Front right
1200 W
INSTALLATION GUIDE built in HL60..E