Operation Manual

105
Secure the hob using the fasteners supplied.
In the case of worktops thinner than 40 mm a filler block has to be used
between the fasteners and the worktop. The screws must be screwed into
the pressed holes.
Connecting up and checking hob
Make the electrical connection by inserting the plug in the socket or set
the switch of the power supply cable (in the case of a fixed
connection) to 1.
Test to check the hob is operational.
INSTALLATION GUIDE built in HL60..E
Above a 90 cm ATAG oven or an oven of another make without
casing cooling.
Fit a heat-resistant (85 °C) plate to screen off the hob. Ensure that the
space between the hob and the protective plate is ventilated. This space
must not be connected with the space above the oven.
The space between the underside of the hob and the top of the protective
plate must be at least 25 mm.
Sealing tape
Stick the sealing tape on the underside of the edge.
Don't stick the sealing tape around the corner; rather cut four pieces to
fit effectively in the corners.
Turn the hob over and allow the appliance to sink into the opening.
104
INSTALLATION GUIDE built in HL60..E