User manual

Building In
573
594
5
589
558
548
20
min. 550
20
590
min. 560
min. 550
min. 560
600
20
Securing the appliance to the cabinet
1. Open the appliance door.
2. Fasten the appliance to the cabinet.
Put the four distance holders (A) into
the holes in the frame and then tighten
the four screws (B) supplied with the
appliance.
AB
Electrical installation
Warning! Only a qualified person must
do the electrical installation.
The manufacturer is not responsible if
you do not follow the safety precau-
tions from the chapter "Safety Informa-
tion".
This appliance is supplied with a main plug
and a main cable.
Cable
Cable types applicable for installation or re-
placement: H07 RN-F, H05 RN-F, H05
RRF, H05 VV-F, H05 V2V2-F (T90), H05
BB-F.
For the section of the cable refer to the total
power (on the rating plate) and to the table:
Total power Section of the cable
maximum 1380 W 3 x 0.75 mm²
maximum 2300 W 3 x 1 mm²
maximum 3680 W 3 x 1.5 mm²
The earth cord (green / yellow cable) must
be 2 cm longer than phase and neutral ca-
bles (blue and brown cables).
ENVIRONMENT CONCERNS
Recycle the materials with the symbol .
Put the packaging in applicable containers
to recycle it.
Help protect the environment and human
health and to recycle waste of electrical and
electronic appliances. Do not dispose
16