Specifications

Sheet 14 of 39 Document 12245 Rev. I
Message Table
Instr
Sub-
Instr
Name/(Section)
Data Values
Sent to Amplifier Returned by Amplifier
0E
Local Lockout
(3.7)
To set Local Lockout ON or OFF:
B
LOC_LOCKOUT_SETTING
None
To read the current Local Lockout setting:
None
B
LOC_LOCKOUT_SETTING
B
LOC_LOCKOUT_SETTING
= 30 for Local Lockout OFF, or = 31 for Local Lockout ON.
The state of local lockout is tracked for protocol compatibility, although it will have no
effect on an amplifier without local controls, e.g., an outdoor SSPA without an RCP-
2001 connected.
16 50
Get Output Power
(3.8.1)
None
[±] N
OUTPUT_POWER
16 51
Get Module Temperature
(3.8.2)
Normal use:
None
±N
MODULE_TEMPERATURE
Compatible with multi-module systems:
[ I
MODULE_NUMBER
]
±N
MODULE_TEMPERATURE
[ , I
MODULE_NUMBER
]
For SSPAs using this protocol, I
MODULE
must be equal to 31 or not be present, or a 3F
will be returned for N
MODULE_TEMPERATURE
. I
MODULE_NUMBER
is only returned in the
response if it was sent to the unit.
16 52
Get Module Current
(3.8.3)
Normal use:
None
N
TOTAL_CURRENT
Compatible with multi-module systems:
[I
MODULE_NUMBER
]
N
TOTAL_CURRENT
[ , I
MODULE_NUMBER
]
I
MODULE_NUMBER
is returned only if sent. For outdoor SSPAs, I
MODULE_NUMBER
must be
equal to 31 or not be present, or a 3F will be returned for N
TOTAL_CURRENT
.
Compatible with ANT MNT 1.5x (module number, stage number):
[ [I
MODULE_NUMBER
] , I
STAGE_NUMBER
]
N
TOTAL_CURRENT
[ , I
MODULE_NUMBER
] , I
STAGE_NUMBER
]
I
MODULE_NUMBER
and I
STAGE_NUMBER
are returned only if sent. For SSPAs using this
protocol, both I
MODULE_NUMBER
and I
STAGE_NUMBER
must be equal to 31 or not be present,
or a 3F (“?”) will be returned for N
TOTAL_CURRENT
16 53
Get Input Voltage
(3.8.4)
None
N
INPUT_VOLTAGE
16 54
Get RF Output Status
(3.8.5)
None
01 0 b
MUTED:PARIO
b
MUTED:SERIO
b
MUTED:LOCAL
00
01 b
HICURR_SHTDN
b
GATEVSHT
b
BUC_UNLKINH
0 b
TH_SHTDN
b
RF_INHIBIT
01 000 000
01 000 00 b
EXT_INH_OR_FAST_MUTE
16 55
Get 1:1 Status
(3.8.6)
None
I
UNIT_NUMBER
, I
SYSTEM_VERSION
I
UNIT_NUMBER
identifies whether this SSPA is Unit #1 or #2 on the 1:1 switch. This
value can be “1” (31), “2” (32), or “?” (3F). 3F indicates that the unit number is
unknown due to a failure.
I
SYSTEM_VERSION
is “1” (31) for the version of firmware covered by this document, and
would change in future versions only if a significant change is made to the operation
of the 1:1 system.