Specifications

Document 12245 Rev. I Sheet 15 of 39
Message Table
Instr
Sub-
Instr
Name/(Section)
Data Values
Sent to Amplifier Returned by Amplifier
16 57
Get Firmware Version Info
(3.8.7)
None
“Firmware_Mask_Number” 20 “Firmware_Version”
16 58
Get Total Current
(3.8.8)
None
N
TOTAL_CURRENT
16 59
Get Specific Fault Info
(3.8.9)
[B
ACTIVE_INFO
]
B
LIST_FAULT
… (one code for each reported fault condition)
If B
ACTIVE_INFO
is not present, or is present but not equal to 31, each currently reported
fault condition is listed, whether it is currently active or not. If B
ACTIVE_INFO
is present
and equal to 31 (to request active fault information), the high bit will be set (add 80)
for each code that is still active. See Section 3.8.9 for the complete list of codes.
16 5A
Get Configuration
(3.8.10)
None
B
OPT_PARALLEL_IO
B
OPT_1:1
30 B
OPT_ANT_DL
B
OPT_1:1_SW
B
OPT_BUC
30 31 30 30 30 30
B
OPT_REFLECTED PWR
30 30 , 31 , B
OPT_FAN_MONITOR
B
OPT_XXXX
= 30 if not present (or if disabled), = 31 if present (or enabled).
The option flag for Parallel I/O (B
OPT_PARALLEL_IO
) corresponds to that for “local”
Parallel I/O in previous SSPA versions. Even though the Parallel I/O option is
physically located in the RCP-2001, all other serial messages that handle Parallel
I/O act as if it is local (when present).
The 1:1 option flag (B
OPT_1:1
) indicates whether 1:1 is enabled in the amplifier. In the
original implementation of this protocol, the 1:1 switch flag (B
OPT_1:1_SW
) was intended
to indicate whether the 1:1 switch was connected or not. However, in all versions of
Antenna Mount firmware described by this document, both B
OPT_1:1
and B
OPT_1:1_SW
are set to 31 if the 1:1 option is enabled, or to 30 if it is not.
The 31 in the 8
th
byte indicates the presence of gain control, a standard feature
included in outdoor and antenna-mount SSPAs.
The 31 in the 17
th
byte [following a comma (2C)], represents the number of current
measurements reported by message 16 52, which is always “1” for SSPAs using this
protocol.
16 5B
Get Reflected
Measurement
(3.8.11)
None
[ [ < ] [ > ] [ ± ] N
REFLECTED_PWR
] or [ “U” ] or [ 3F ]
The reflected measurement is returned in the currently selected measurement type
(power, return loss, or VSWR; see 3.10.6). No sign is returned if measurement type
is VSWR, or if measurement type is power and power units are Watts. A leading “<”
or “>” symbol may be present (see 3.8.11). A “U” (55) will be returned for
“undefined”. A 3F will be returned if the reading is not available because the option is
disabled, or because of a detector failure.
16 5C
Get Parallel Inputs
(3.8.12)
None
[ 01 b
PIO_INPUT_R6_ACTIVE
b
PIO_INPUT_R5_ACTIVE
b
PIO_INPUT_R4_ACTIVE
b
PIO_INPUT_R3_ACTIVE
b
PIO_INPUT_R2_ACTIVE
b
PIO_INPUT_R1_ACTIVE
01 000 0 b
PIO_INPUT_R8_ACTIVE
b
PIO_INPUT_R7_ACTIVE
01 000 000
01 b
PIO_INPUT_R6_LATCHED
b
PIO_INPUT_R5_LATCHED
b
PIO_INPUT_R4_LATCHED
b
PIO_INPUT_R3_LATCHED
b
PIO_INPUT_R2_LATCHED
b
PIO_INPUT_R1_LATCHED
01 000 0 b
PIO_INPUT_R8_LATCHED
b
PIO_INPUT_R7_LATCHED
01 000 000 ]
if Parallel I/O is present (option available in the RCP-2001); or,
[ 3F ] if Parallel I/O is not present.
16 5D
Get Latched Analog Faults
(3.8.13)
None
01 000 000
01 000 000
01 0 b
LSUM_VOLTAGE
0 000