Specifications

Document 12245 Rev. I Sheet 17 of 39
Message Table
Instr
Sub-
Instr
Name/(Section)
Data Values
Sent to Amplifier Returned by Amplifier
17 58
Power-Up State
(3.9.7)
To set state:
B
POWER_UP_SETTING
None
To read currently set state:
None
B
POWER_UP_SETTING
B
POWER_UP_SETTING
= 30 for Muted, = 31 for Operating, = 32 for Previous state
17 59
Parallel Output Functions
(3.9.8)
To set functions:
B
PIO_OUTPUT_FUNCTION_R1
[B
PIO_OUTPUT_FUNCTION_R2
[B
PIO_OUTPUT_FUNCTION_R3
[B
PIO_OUTPUT_FUNCTION_R4
[B
PIO_OUTPUT_FUNCTION_R5
[B
PIO_OUTPUT_FUNCTION_R6
[B
PIO_OUTPUT_FUNCTION_R7
[B
PIO_OUTPUT_FUNCTION_R8
] ] ] ] ] ] ]
None
To read currently set functions:
None
B
PIO_OUTPUT_FUNCTION_R1
B
PIO_OUTPUT_FUNCTION_R2
B
PIO_OUTPUT_FUNCTION_R3
B
PIO_OUTPUT_FUNCTION_R4
B
PIO_OUTPUT_FUNCTION_R5
B
PIO_OUTPUT_FUNCTION_R6
B
PIO_OUTPUT_FUNCTION_R7
B
PIO_OUTPUT_FUNCTION_R8
When setting, send a 3F to leave any particular function unchanged. See Section
3.9.8 for a complete list of available PIO output functions.
17 5A
Output Power Calibration
Offset (3.9.9)
To set value:
±N
POUT_OFFSET
None
To read currently set value:
None
±N
POUT_OFFSET
17 5B
Reflected Power
Calibration Offset
(3.9.10)
[ ±N
REFLECTED_POWER_CAL_OFFSET
]
[ ±N
REFLECTED_POWER_CAL_OFFSET
]
17 5F
Local/Remote Settings
(3.9.11)
To set value:
B
LOCAL_WARNING_SETTING
[B
REMOTE_DISABLES_LOCAL_SETTING
]
None
To read currently set value:
None
B
LOCAL_WARNING_SETTING
B
REMOTE_DISABLES_LOCAL_SETTING
B
LOCAL_WARNING_SETTING
= 30 for Disabled, = 31 for Enabled; send 3F to
leave unchanged (when setting).
B
REMOTE_DISABLES_LOCAL_SETTING
= 30 for No, = 31 for Yes; send 3F to leave
unchanged (when setting).
17 61
Reflected Power Fault
Limit
(3.9.12)
[ [ > ] [ ±N
REFLECTED_POWER_LIMIT
] ]
[ [ > ] ±N
REFLECTED_POWER_LIMIT
]
Reflected Power Fault Limit is always represented as a power measurement in the
current power units (dBm, dBW, or Watts) regardless of the setting of the Reflected
Measurement Type. Send just a “>” to disable the Reflected Power Fault Limit.
17 62
Reflected Power
Fault/Warning
(3.9.13)
[ B
REFLECTED_POWER_FAULT_WARNING
]
[ B
REFLECTED_POWER_FAULT_WARNING
]
B
REFLECTED_POWER_FAULT_WARNING
= 30 for Warning; or = 31 for Fault.
18 50
Mute Control
(3.10.1)
To set mute/operate control:
B
MUTE_CONTROL
None
To read current setting:
None
B
MUTE_CONTROL