Specifications

Sheet 22 of 39 Document 12245 Rev. I
01 00 b
AFLT_ANT_DL_FAIL
b
AFLT_RC_FAILURE
b
AFLT_FAN2_WARN
b
AFLT_FAN1_WARN
b
xFLT_EXT_INH
One or more signals that inhibit the RF output have become shorted
or disconnected.
b
xFLT_POUT_HI
The output power of the amplifier has risen above the user-set fault
limit.
b
xFLT_POUT_LO
The output power of the amplifier has dropped below the user-set
fault limit.
b
xSUM_MODULE
Indicates a failure in the main RF module.
b
xFLT_VINP_HI
The voltage input to the amplifier module is too high, which most
likely indicates that the supply needs adjustment.
b
xFLT_VINP_LO
The voltage input to the amplifier module is too low, which could
indicate a failure of a power supply module, or that the supply has
drifted out of adjustment.
b
xFLT_LOCAL_WARN
The Local Mode warning is in effect.
b
xFLT_MAINT_WARN
The Maintenance Mode warning is in effect.
b
xFLT_INPRn
A Fault is generated by the corresponding Parallel I/O Input (n),
programmed to either a FAULT.L or FAULT.H.
b
xFLT_BUC_FAIL
The BUC (optional) has unlocked, lost power, or has become
disconnected from the module.
b
xFLT_REFL_DET_WARN
Something is wrong with the Reflected Power Detector Module, and
Reflected Power Fault/Warning is set for WARNING.
b
xFLT_PREFL_DET_FAULT
Something is wrong with the Reflected Power Detector Module, and
Reflected Power Fault/Warning is set for FAULT.
b
xFLT_PREFL_HI_WARN
These flags indicate
(i) the reflected power is high (above the fault limit, which is
enabled), and
(ii) it has been at least 100 ms since the last 1:1 switch change, and
(iii) the Reflected Power Fault/Warning is set for WARNING.
b
xFLT_PREFL_HI_FAULT
These flags indicate
(i) the reflected power is high (above the fault limit, which is
enabled), and
(ii) it has been at least 100 ms since the last 1:1 switch change, and
(iii) the Reflected Power Fault/Warning is set for FAULT.
b
xFLT_TEST_FW_WARN
The wrong firmware has been installed in the amplifier at the factory.
b
xFLT_REL_PWR
The output power of this amplifier is significantly below that of the
other unit in a 1:1 system.
b
xFLT_ANT_DL_FAIL
The Antenna-Dummy Load switch failed to operate, either because
the switch is disconnected or the power supply to the switch has
failed.
b
xFLT_RC_FAILURE
Something is wrong with the “Redundancy Controller” board, which
also is used to connect the Reflected Power Detector and the Fan
Monitor.
b
xFLT_FANn_WARN
The corresponding fan’s rotational speed is below the fault threshold,
and enough time has elapsed since the last reset that the fan should
have achieved its normal velocity.