Specifications

Document 12245 Rev. I Sheet 27 of 39
Fault Codes
SIO Code
(16 59)
Screen Text
1
(RCP-200X)
SIO 08 flag
2
NEW_INFO
SIO 08 flag
2
(old style)
Description
42
Local Warn b
XFLT_LOCAL_WARN
b
XFLT_LOCAL_WARN
Warning that you have set Local mode (which
prevents remote control).
43
Maint Warn b
XFLT_MAINT_WARN
b
XFLT_MAINT_WARN
Warning that you have set Maintenance mode.
44
Manl Warn (N/A) (N/A) Reserved (not used at this time)
45
InpR1 b
XFLT_INPR1
b
XSUM_INPUT
Parallel I/O input 1 fault (RCP-200x).
46
InpR2 b
XFLT_INPR2
b
XSUM_INPUT
Parallel I/O input 2 fault (RCP-200x).
47
InpR3 b
XFLT_INPR3
b
XSUM_INPUT
Parallel I/O input 3 fault (RCP-200x).
48
InpR4 b
XFLT_INPR4
b
XSUM_INPUT
Parallel I/O input 4 fault (RCP-200x).
49
InpR5 b
XFLT_INPR5
b
XSUM_INPUT
Parallel I/O input 5 fault (RCP-200x).
4A
InpR6 b
XFLT_INPR6
b
XSUM_INPUT
Parallel I/O input 6 fault (RCP-200x).
4B
InpR7 b
XFLT_INPR7
b
XSUM_INPUT
Parallel I/O input 7 fault (RCP-200x).
4C
InpR8 b
XFLT_INPR8
b
XSUM_INPUT
Parallel I/O input 8 fault (RCP-200x).
4D
Vreg Adj b
XSUM_MODULE
b
XSUM_HARDWARE
Power supply voltage to RF section is out of
range.
4E
RelPwr b
XFLT_REL_PWR
b
XSUM_OUTPUT_POWER
This amplifier’s output level is significantly
lower than the other in a 1:1 system.
50
RefDet Wrn b
XFLT_REFL_DET_WARN
b
XSUM_HDW_WARN
Reflected Power Detector has failed (set for
Warning).
51
PreflHiWrn b
XFLT_PREFL_HI_WARN
b
XSUM_PREFL_HI
Reflected power is too high (set for Warning).
57
AntDL Fail b
XFLT_ANT_DL_FAIL
b
XSUM_RC_FAILURE
The Antenna-Dummy Load switch is discon-
nected or the power supply to the switch has
failed.
77
SpurRst b
XSUM_MODULE
b
XSUM_HARDWARE
CPU has been unexpectedly reset.
78
EE Data b
XSUM_MODULE
b
XSUM_HARDWARE
Control settings have been lost.
79
EE Write b
XSUM_MODULE
b
XSUM_HARDWARE
CPU detected an error writing settings to non-
volatile memory.
7A
Test Firmw b
XFLT_TEST_FW_WARN
b
XSUM_HDW_WARN
The wrong firmware has been loaded into your
amplifier.
7B
Fan1 Warn b
XFLT_FAN1_WARN
b
XSUM_FAN
Fan 1 speed is too slow.
7C
Fan2 Warn b
XFLT_FAN2_WARN
b
XSUM_FAN
Fan 2 speed is too slow.
7D
RefDet Flt b
XFLT_REFL_DET_FLT
b
XSUM_HARDWARE
Reflected Power Detector has failed (set for
Fault).
7E
PreflHiFlt b
XFLT_PREFL_HI_FLT
b
XSUM_PREFL_HI
Reflected power is too high (set for Fault).
1
“Screen Text” displayed on an attached RCP-200x is included for information only.
2
The notation for the bit flags in the 08 message indicate whether each flag maps directly to a single fault condition
(b
XFLT_NNNNN
) or summarizes more than one fault condition (b
XSUM_NNNNN
). The
X
in this notion represents an ‘A’ for the
Active fault flags, or an ‘L’ for the Latched fault flags.