User's Manual

PART# PART DESCRIPTION
PRT5493-01 BRASS POST ADAPTER FEMALE SET
PRT5493-02 BRASS POST ADAPTER MALE SET
PRT5493-03 CARRYING CASE
PRT5493-04 LOCAL TRANSMITTER MODULE
PRT5493-05 WIRELESS TO IR TO USB MINI CABLE
RETURN FOR REPAIR POLICY
Every effort has been made to provide reliable, superior quality products. However, in the event your instrument
requires repair, forward unit to Service Center freight prepaid to the address below with return address, phone
number and/or email address.
TECHNO TOOLS TOOLS
SERVICE CENTER
2651 W 81st Street
Hialeah, FL 33016
WARRANTY POLICY
The ATD 5493 Battery System Tester is warranted to be free of defects in materials and workmanship for a period
of two years from the date of purchase. This warranty applies to all repairable instruments that have not been
tampered with or damaged through improper use including unauthorized opening of the unit. Please ship warranty
units that require repair freight prepaid to Service Center along with proof of purchase, return address, phone
number and/or email address.
REPL
ACEMENT PARTS
PRODUCT SPECIFICATIONS
Model #
ATD 5493
Name
Electrical System Analyzer
Battery Size Range
100 CCA to 3500 CCA
DC Voltage: Range/Accuracy
3.0V to 49.9V/ +/- 2% reading
LCD Display
2 line-16 character
mA Range (Parasitic drain test)
5 mA to 1,000 mA
Power Supply
9V (Internal Battery)
Cable Length (Local Transmitter)
2 Ft.
Wireless Signal
900MHz (Custom Protocol)
Weight, lbs
1.5 lbs
Warranty
2 years
Wireless Range
Approx. 50 Ft. (depending on the
environment)
USB ADAPTER Specifications
Normal dist. from Tester to Adapter:
18” to 20 ft (depending on environment)
USB Cable:
Mini USB
USB cable length:
36”
Operating Temperature:
32°F to 120°F
Weight:
.25 LBS