E2695A 8-GHz differential SMA
probe head
allows you to connect
two SMA cables to make a differential
measurement on a single scope channel.
N5381A 13-GHz high-
bandwidth solder-in differential
probe head
provides maximum
bandwidth and minimizes capacitive loading
to ≤ 210 fF. Variable spacing from
0.2 to 3.3 mm (8 to 130 mills).
E2679A 6-GHz extremely
small single-ended, solder-in
probe heads
for probing even the
hardest-to-reach single-ended signals.
E2677A 12-GHz solder-in
differential probe head
can be
attached to very-small-geometry circuits
for measuring both single-ended and
differential signals. External mini-coaxial
resistors facilitate wider span but have
increased high-frequency response
variation relative to N5381A.
N5425A 13-GHz high-
bandwidth solder-in differential
ZIF probe head and N5426A
ZIF tip
provides maximum bandwidth
with the industry’s first lead-free solder-
in probe solution in an economical
replaceable tip form factor.
N5451A 9-GHz/5-GHz long-wire
ZIF tip
provides a high-bandwidth
economical replaceable solder-in tip with
extra reach (9 GHz with 7 mm and 5 GHz
with 11 mm wire).
InfiniiMax offers you the high-
est performance
available for mea-
suring differential and single-ended signals,
with flexible connectivity solutions for
today’s high-density ICs and circuit boards.
InfiniiMax probes have fully
characterized performance
for all
of their various probe heads. This includes:
Swept frequency response plot
Common mode rejection versus
frequency plot
Impedance versus frequency plot
Time-domain probe loading plot
Time-domain probe tracking plot
One-year standard warranty on
active probes and a variety of Agilent
support options to choose from.
Controlled impedance
transmission lines
in every probe
head deliver full performance versus the
performance limitations introduced by
traditional wire accessories.
Probe interface software allows
you to save the calibration information for
up to 10 different probe heads per channel
and will automatically retrieve calibration
data for a probe amplifier when attached to
the scope.
High-input impedance active
probes
minimize loading, support
differential measurements and DC offset,
and can compensate for cable loss.
Probe calibration software
delivers the most accurate probe
measurements and linear phase response
and allows various probe combinations to
be deskewed to the same reference time.
A flat frequency response over
the entire probe bandwidth eliminates the
distortion and frequency-dependent loading
effects that are present in probes that have
an in-band resonance.
N5426A
N5451A
InfiniiMax II: The World’s best high-speed probing system
just keeps getting better