Technical Data Sheet Power Meters & Power Sensors ML2430A CW Power Meter ML2480B Wideband Power Meter ML2490A Pulse Power Meter MA2400A/D & MA24000A Power Sensors Anritsu Power Meters and Power Sensors: Accurate, Fast, and Affordable.
Power Meter Specifications ML2430A, ML2480B, ML2490A Introduction Anritsu offers the world’s most comprehensive range of power meters. The ML2490A series has the performance required for narrow, fast rising-edge pulse power measurements (for example, radar), while the ML2480B series is suited for wideband power measurements on signals such as W-CDMA, WiMAX, LTE, and WLAN.
ML2430A, ML2480B, ML2490A Power Meter Specifications Power Meter Performance ML2430A Series Number of Input Signals Frequency Range Dynamic Range Continuous or Peak 1 (ML2437A) 2 (ML2438A) ML2480B Series 1 (ML2487B) 2 (ML2488B) ML2490A Series 1 (ML2495A) 2 (ML2496A) 100 kHz to 65 GHz (sensor dependent) –70 to +20 dBm (dependent on sensor, external coupler or attenuator) Pulse/Modulated mode > 65 MHz range 7 > 38 MHz range 8 > 16 MHz range 9 (Repetitive Sampling) Pulse/Modulated mode 20 MHz with MA2491
Power Meter Specifications ML2430A, ML2480B, ML2490A Operation ML2430A Series Measurement Display Readout (Numerical) Measurement Display Profile (Graph) ML2480B Series 2 2 (CW or Pulse/Modulated measurement modes) Power vs.
ML2430A, ML2480B, ML2490A Power Meter Specifications Averaging ML2430A Series Type Range Low-level Averaging ML2480B Series ML2490A Series ML2480B Series ML2490A Series Auto (Moving), Manual (Moving, Repeat) 1 to 512 Low, Medium and High settings apply post average low pass filter to improve visibility at high display resolution. N/A Triggering ML2430A Series Source Trigger Modes Nominal Internal Trigger Bandwidth Internal, External (TTL or RF Blanking), GPIB, Manual, or Continuous.
Power Meter Specifications ML2430A, ML2480B, ML2490A System Configuration ML2430A Series Save/Recall Secure Mode 10 storage registers plus RESET default settings ML2480B Series ML2490A Series 20 settings stores Preset accessible on Front Panel Offset tables Wipes non-volatile memory on power up when active. Interfaces ML2430A Series ML2480B Series Remote Monitoring Yes No Modem Compatibility Yes No ML2490A Series > 400 Readings/second CW Mode [TR3 Mode] GPIB (IEEE–488.
ML2430A, ML2480B, ML2490A Power Meter Specifications Reference Calibrator ML2430A Series Reference Calibrator Power ML2480B Series Power Accuracy (Traceable to National Standards) ± 1.2 % per year Frequency 50 MHz (nominal) 50 MHz (standard) 1 GHz (optional) Frequency Accuracy <1% < 1 % (50 MHz) < 2 % (1 GHz) VSWR < 1.04 < 1.12 (50 MHz) < 1.
Power Sensor Specifications ML2430A, ML2480B, ML2490A Power Sensor Performance Frequency Range Sensor CW Dynamic Range (dBm) SWR Rise Time1 (ms) Sensor Linearity7 RF Connector2 Standard Diode Sensors MA2472D MA2473D 10 MHz to 18 GHz 10 MHz to 32 GHz MA2474D 10 MHz to 40 GHz MA2475D 10 MHz to 50 GHz –70 to +20 CW mode –43 to +20 (ML243xA, Profile mode) –37 to +20 (ML2480A/B or ML2490A, Pulse/Mod mode) < < < < 1.17; 1.12; 1.22; 1.25; 10 MHz to 150 MHz 150 MHz to 2 GHz 2 GHz to 12.4 GHz 12.
ML2430A, ML2480B, ML2490A Power Sensor Specifications Measurement Accuracy Power measurement accuracy can be split into several parts. The table below shows how the measurement uncertainty is composed for several power sensors. The source is presumed to be a 16 GHz, 12.0 dBm signal with a source SWR of 1.5:1. The uncertainties can be calculated as an RSS term as each parameter is independent. Alternatively they can be added together for a worst-case analysis.
Ordering Information Power Meters & Sensors ML2430A, ML2480B, ML2490A Power Meters & Sensors Selection Guide Standard Diode MA2470D Series Power Sensors Model Number Power Measurement Measurement Application (Examples) Choose the right power meter and power sensor for your measurement application.
Power Meters & Sensors ML2430A, ML2480B, ML2490A Power Sensor Models Ordering Information General Options and Accessories MA2472D Standard diode sensor (10 MHz to 18 GHz, –70 dBm to 20 dBm) 760–209 MA2473D Standard diode sensor (10 MHz to 32 GHz, –70 dBm to 20 dBm) D41310 MA2474D Standard diode sensor (10 MHz to 40 GHz, –70 dBm to 20 dBm) 2000-1535 MA2475D Standard diode sensor (10 MHz to 50 GHz, –70 dBm to 20 dBm) 2000-1536-R 0.
To receive a quote to purchase a product or order accessories visit our online ordering site: www.ShopAnritsu.com Training at Anritsu Anritsu has designed courses to help you stay up to date with technologies important to your job. For available training courses visit: www.anritsu.com/training • United States Anritsu Company 1155 East Collins Blvd., Suite 100, Richardson, TX 75081, U.S.A. Toll Free: 1-800-267-4878 Phone: +1-972-644-1777 Fax: +1-972-671-1877 • Canada Anritsu Electronics Ltd.