Instruction Manual

4
JD725A CABLE AND ANTENNA ANALYZER
Cable Loss
Cable Loss measures the amount of signal lost by the cable line, this mea-
surement facilitates a rapid compliance verification analysis throughout
the transmission line.
Frequency range: 25 to 4000MHz•
Dynamic Range: 0 to 30dB•
User denable limit line for fast Pass/Fail characterization•
Insertion Gain / Loss
The Insertion Gain measurement simplifies the task of verifying ampli-
fiers and antenna isolation.
Insertion Loss measurements accurately quantifies the amount of signal
loss as it passes through a cable, attenuator, filter, amplifier or any other
RF device.
Frequency range: 25 to 4000MHz•
Dynamic Range: -90 to 50dB•
User denable limit line for fast Pass/Fail characterization•