Owner manual

Table Of Contents
Noise Laboratory Co., Ltd.
1-4-4 Chiyoda, Chuo-ku, Sagamihara City, Kanagawa Pref. 252-0237 Japan
International Sales & Marketing Section
TEL : +81-(0)42-712-2051/FAX : +81-(0)42-712-2050
E-mail : sales@noiseken.com
URL : http://www.noiseken.com
Terminal Connection Board attached with Multi-Outlet MODEL18-00048B/58B
Enable to connect any outlet figure in the world.
18-00048B : For single phase 3 lines (Voltage strength 4.5kV)
18-00058B : For 3-phase 5 lines (Voltage strength 4.5kV)
Optical USB module MODEL07-00022A
Optical conversion adaptor Used for remote
control with PC. 5m of optical fiber cable with
USB interface attached.
Warning lamp MODEL11-00008A
CDN for Telecom lines
 MODELLSS-INJ6401TEL
The blinking makes the operators or neighbors pay
attention to the test processing.
EUT Protective Safety Box MODEL11-00005A/11-00006A
Protection box to prevent access to EUT during the test.
Further safety is secured together with the safety
protective fence
CDN for interconnection lines MODELLSS-INJ6400SIG
Adaptable for the test to interconnection lines
specified in IEC61000-4-5 Standard. Arrestor
installation possible in between the each line and
GND.
* Please contact us if low voltage surge injection is required
Parameter Specification
Surge input voltage 500V∼6,600V
EUT power capacity DC50V/1A
Max. line number 4 lines
Decoupling coil 20mH per phase
Matching resistor 40Ω±10%
Dimension / Mass W488×H456×D550mm Approx. 45kg
CDN for 3-phase EUT MODELLSS-CDN6351
Adaptable for the surge immunity test specified in IEC61000-4-5 Standard to AC power supply lines of EUT whose power supply up to
AC500V/50A. The surge injection angle can be set automatically linked with the generator unit. Also, the line symmetrical operation to AC
lines is possible. * Scheduling to be released
* Photo in the development stage
* Photo in the development stage
Parameter Specification
Coupling surge waveform 1.2/50μs-8/20μs combination waveforms, 0.5μs-100kHz ring wave
Max. coupling surge voltage / current Up to the value which can be set in LSS-6230
Coupling network 18μF±10%(LINE - LINE)
Correspondent to IEC 61000-4-5 10Ω+9μF±10%(LINE - PE)
Coupling network 18μF±10%(LINE - LINE, LINE - PE)
ICorrespondent to IEEE/ANSI C62.45 9μF/9μF/9μF/9μF±10%(4 Lines - PE simultaneous injection)
Power supply lines structure for EUT 3-phase : L1/L2/L3/N/PE
EUT power capacity AC500V/50A MAX 50/60Hz
Decoupling coil 1.5mH
Power supply AC100V∼AC240V ±10% 50Hz / 60Hz
Dimension / Mass W555×H950×D790 mm(Projection excluded) Approx. 120kg(To be fixed)
Isolation transformer MODELTF-2302P
Versatilely usable not only for AC power supply of our
lightning surge simulators but also for kinds of noise
testes and measurement equipments.
Adaptable for the test to unshielded symmetrical
interconnection lines specified in IEC61000-4-5
Standard
Parameter Specification
Max. input voltage Single phase AC 240V MAX (50/60Hz)
Max. output voltage 30A MAX
Dielectric strength Primary to core : AC4kV (1 minute)
Secondary to core : AC4kV (1 minute)
Primary-Secondary : AC4kV (1 minute)
Insulation resistance 100MΩ at DC500V
Dimension / Mass W350×H475×D 400mm
(Eye bolts and handles excluded) Approx. 60 kg
Parameter Specification
Surge input voltage 6.6V 10/700μs-5/320μs Combination waveform
EUT power capacity DC50V 0m
No. of line 4 lines
Decoupling coil 20mH per phase
Matching resistor 40Ω(in combination waveforms)
25Ω(in 10/700μ waveform)
Dimension / Mass W297×H262×D250mm Approx. 10kg
Loop coil
 MODEL01-00057A
In the combination with LSS-6230, enable to
conduct pulse magnetic field immunity test
specified in IEC61000-4-9 Standard
* Scheduling to be released
Parameter Specification
Max. output voltage 1200A
Waveform 6.4/16μAcurrent surge
Coil dimension 1000×1000mm
MODEL Dimension
11-00005A W400×D300×H300mm
11-00006A W600×D350×H400mm
Option
Designs and specifications are subject to be changed without notice.