Instruction Manual
Version 08.00, June 2011
14 Rohde & Schwarz R&S
®
FSH4/FSH8 Spectrum Analyzer
Composite EVM SNR > 30 dB
Measurement range –40 dBm < P
RF channel
< 20 dBm 1.5 % < EVM < 25 %
1.5 % < EVM ≤ 10% typ. 2.0 % Measurement uncertainty
10 % < EVM < 25 % typ. 2.5 %
Residual EVM typ. 2.5 %
Rho SNR > 30 dB
Measurement range –40 dBm < P
RF channel
< 20 dBm 0.9 < Rho < 1
0.97 < Rho ≤ 1.0 typ. 0.005 Measurement uncertainty
0.90 < Rho ≤ 0.97 typ. 0.02
R&S
®
FSH-K47 1xEV-DO
®
BTS pilot channel and EVM measurement
application
The specifications below apply to the R&S
®
FSH4 and R&S
®
FSH8. They are based on the data sheet specifications of the R&S
®
FSH4
and R&S
®
FSH8, have not been checked separately and are not verified during instrument calibration. Measurement uncertainties are
indicated as 95 % confidence intervals. The specified level measurement errors do not take into account systematic errors due to
reduced signal-to-noise ratio (SNR).
Measurements R&S
®
FSH-K47
Spectrum overview ●
Result summary ●
RF channel power ●
Pilot Rho ●
Carrier frequency error ●
Traffic activity ●
Pilot EVM ●
PN timing (tau) ●
Peak to average ●
Pilot power ●
MAC power ●
Data power ●
All specifications are valid for RC3, one traffic channel, SNR > 30 dB, +15 °C to +35 °C.
Frequency range 15 MHz to 3.0 GHz
Carrier frequency uncertainty, nominal values
Lock range ±5 kHz
Measurement uncertainty SNR > 30 dB,
Δf
ref
= uncertainty of reference frequency
< 100 Hz + Δf
ref
RF channel power
frequency > 15 MHz
preamplifier = OFF –60 dBm < P
RF channel
< 20 dBm
Measurement range
preamplifier = ON –75 dBm < P
RF channel
< 20 dBm
Measurement uncertainty –75 dBm < P
RF channel
< 20 dBm,
ref. level adjusted to RF channel power
< 1 dB, typ. 0.5 dB
Pilot power SNR > 30 dB
Measurement range –40 dBm < P
RF channel
< 20 dBm P
RF channel
– 20 dB < P
PICH
< P
RF channel
Measurement uncertainty P
RF channel
– 20 dBm < P
CPICH
< P
RF channel
< 1 dB, typ. 0.5 dB
MAC power SNR > 30 dB
Measurement range –40 dBm < P
RF channel
< 20 dBm P
RF channel
– 20 dB < P
SYNC
< P
RF channel
Measurement uncertainty P
RF channel
– 20 dBm < P
SYNC
< P
RF channel
< 1 dB, typ. 0.5 dB
Data power SNR > 30 dB
Measurement range –40 dBm < P
RF channel
< 20 dBm P
RF channel
– 20 dB < P
SYNC
< P
RF channel
Measurement uncertainty P
RF channel
– 20 dBm < P
SYNC
< P
RF channel
< 1 dB, typ. 0.5 dB
Pilot EVM SNR > 30 dB
Measurement range –40 dBm < P
RF channel
< 20 dBm 1.5 % < EVM < 25 %
1.5 % < EVM ≤ 10% typ. 2.0 % Measurement uncertainty
10 % < EVM < 25 % typ. 2.5 %
Residual EVM typ. 2.5 %
Pilot Rho SNR > 30 dB
Measurement range –40 dBm < P
RF channel
< 20 dBm 0.9 < Rho < 1
0.97 < Rho ≤ 1.0 typ. 0.005 Measurement uncertainty
0.90 < Rho ≤ 0.97 typ. 0.02