User guide
Advanced Test Solutions for EMC
Teseq AG
Nordstrasse 11F 4542 Luterbach Switzerland
T + 41 32 681 40 40 F + 41 32 681 40 48
sales@teseq.com www.teseq.com
THE MODULAR SOLUTION FOR 6 KV APPLICATIONS
NSG 3060
691-130B August 2009
Parameter Value
Pulse amplitude: ±200 V to 4.8 kV (in 1 V steps) - open circuit
±100 V to 2.4 kV (50 Ω matching system)
Burst frequency: 100 Hz to 1000 kHz
Polarity: positive / negative / alternate
Repetition time: 1 ms to 4200 s (70 min)
Burst time: 1 µs to 1999 s, single pulse, continuous
Test duration: 1 s to 1000 h
Phase synchonization: asynchronous, synchronous 0 to 359º (in 1º steps)
Coupling: ANSI / IEC / external
Burst (EFT) 5/50 ns
Pulse conforms to IEC/EN 61000-4-4
Dips & drops
conforms to IEC/EN 61000-4-11
Parameter Value
Dips & drops: From EUT voltage input to 0 V, 0%
Uvar with optional variac: depending on model (VAR 650x)
Uvar with step transformer: 0, 40, 70, 80% (INA 650x)
Peak inrush current capability: 500 A (at 230 V)
Switching times: 1 to 5 μs (100 Ω load)
Event time: 20 µs to 1999 s, 1 to 99’999 cycles
Test duration: 1 s to 70’000 min, 1 to 99’999 events, continuous
Repetition time: 40 µs to 35 min, 1 to 99’999 cycles
Phase synchronization: asynchronous, synchronous 0 to 359º (in 1º steps)
Variation test
conforms to IEC/EN 61000-4-11
Parameter Value
Uvar with optional variac: 0 to 265 V (in 1 V steps), 0 to 115% (in 1% steps)
Repetition time: 1 ms to 35 min, 1 to 99’999 cycles
Test duration: 1 ms to 5 s, 1 to 250 cycles (50 Hz);
1 to 300 cycles (60 Hz), abrupt
Repetition time: 10 ms to 10 s; 1 to 250 cycles (50 Hz), 1 to 300 cycles (60 Hz)
Test duration: 1 s to 99’999 min, 1 to 99’999 events, continuous
Phase synchronization: asynchronous, synchronous 0 to 359º (in 1º steps)