User guide
Meters, Monitors,
Controls & Indicators
Meters: Helix Current
Filament Elapsed Time (Option H)
Monitors: RF Output Sample (Option E)
Controls: Mains Power ON/OFF
High Voltage ON/OFF – Fault Reset
Local/Remote (Option G)
RF Attenuator (Option B)
Indicators:
• Mains Power ON
•
Helix Current Fault
• Filament Time Delay • TWT Over-temperature
• Standby • External Interlock Fault (option G)
• High Voltage On • Remote Control (option G)
• Summary Fault • Reflected Power Fault (option M)
• Cover Interlock Fault • Power Supply Fault
Mechanical &
Environmental
Ambient Temperature: 0 to 50°C
Relative Humidity: to 95% non Condensing
Altitude: to 10,000 feet max. Derate temperature 2°C/1,000 feet
above 4,000 feet.
Shock & Vibration: As normally encountered in a protected engineering
laboratory environment.
Cooling: Forced air with integral blower, air intake and exhaust in
rear.
RF Connectors: Type N(female), on rear panel (front panel w/Option j)
Frequency (GHz) Type
1-2 N (female)
2-4 N (female)
4-8 N (female)
8-12.4 UG-39/U (WR-90)
12.4-18 UG-419/U (WR-62)
8-18 MIL-F-39000/3-74 (WRD-
750)
Prime Power: 115 Vac ±10%, 47-63Hz, single phase
230 Vac (option K)
Power Consumption: 1900 Watts for 100W TWT models
2400 Watts for 200W TWT models
Dimensions: 12.25”H x 19”W x 24”D
Weight: 195 Lbs./ 89 Kg.
3