54
Timeout
The Timeout setting applies to ports with the Occupy I/O attribute. It controls
the amount of time (0-255 seconds) that elapses before an inactive user is timed
out when other users are waiting to take control of the port. Once the first user
becomes inactive (i.e. stops sending keyboard and mouse input), it begins to
countdown the amount of time specified in the Timeout field. If the user does
not send input before the time expires, that user is timed out and the port is
released. The next user to send mouse or keyboard input gains control of the
port.
To apply Timeout settings:
1. Click Attributes... on the Customization dialog box. The Setting I/O
Attributes dialog box appears (see Attributes, page 52).
2. In the Timeout field, enter the Timeout time in seconds.
3. Click Apply. (To exit without saving your changes, click Cancel.)
Note: The Timeout setting applies to all ports on the KL9108 / KL9116.
Miscellaneous
The functions performed by the remaining elements at the bottom of the screen
are described in the table below:
Parameter Explanation
Reset on exit
Select this check box to reset the KL9108 / KL9116
and
implement new settings when you log out. Following a reset,
wait one to two minutes before logging back in.
Note: For some changes the Reset on exit check box is
automatically selected and the KVM switch will reset when
you log out. Clearing the check mark before logging out will
cause the new settings to be discarded.
Reset Values Clicking this button undoes all changes that have been made
to the Configuration and Administration pages (except for port
names, usernames, and passwords) and returns the
parameters to the original factory default settings (see OSD
Factory Default Settings, page 123).
Clear Name List This function clears the Port Names on the Main page.