User manual

CM1164 User Manual
82
(Continued from previous page.)
Symptom Possible Cause Action
When switching
ports, the monitor
does not display.
Monitor is new or
this is a first time
installation.
Switch ports again and wait two or more
seconds for the PC’s EDID to pass to the
monitor.
The PC’s EDID
has not passed
through to the
monitor when
switching ports
Use the [d] hotkey to invoke Video DynaSync
one more time or switch to another PC to
reconnect the CM1164. See Video DynaSync,
page 34 or Video DynaSync, page 55.
The GUI
connection
window stalls /
does not connect
The CM1164
needs to be reset.
Perform a KVM reset or reinstall the latest
CM1164 software on all your computers.