User manual

19
Chapter 3
Basic Operation
Hot Plugging
The CS1708A / CS1716A supports hot plugging – components can be removed
and added back into the installation by unplugging their cables from the ports
without the need to shut the unit down. In order for hot plugging to work
properly, however, the procedures described below must be followed:
Changing Station Positions
You can change a station’s position by simply disconnecting it from its master
and reconnecting it to another switch in the chain. In order for the OSD menus
to correspond to the change, the station IDs must be reset in the OSD. See
RESET STATION IDS, page 32 for details.
Hot Plugging KVM Ports
In order for the OSD menus to correspond to KVM port changes, you must
manually reconfigure the OSD to reflect the new port information. See the F3
SET (page 28) and F4 ADM (page 30), functions for details.
Note: If the computer's operating system does not support hot plugging, this
function may not work properly.
Hot Plugging Console Ports
The keyboard, monitor, and mouse can all be hot plugged. When hot plugging
the mouse:
ī‚Š You may unplug and replug the mouse (to reset the mouse, for example),
as long as you use the same mouse.
ī‚Š If you plug in a different mouse, all the stations and all the computers on
the installation must be shut down for 10 seconds, then restarted following
the power up sequence described under Step 5 on page 16.
Note: If, after hot plugging there is no response to keyboard and/or mouse
input, perform a Keyboard and Mouse Reset by simultaneously
pressing the 1 and 2 front panel port LEDs.